2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000


###  http://saref.linkeddata.es/def/bldg#tankAccessType
bldg:tankAccessType rdf:type owl:DatatypeProperty ;
                    rdfs:domain bldg:Tank ;
                    rdfs:range xsd:string ;
                    rdfs:comment "Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole."@en ;
                    rdfs:label "access type"@en .


###  http://saref.linkeddata.es/def/bldg#tankEffectiveCapacity
bldg:tankEffectiveCapacity rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Tank ;
                           rdfs:range xsd:float ;
                           rdfs:comment " The total effective or actual volumetric capacity of the tank. Usually measured in cubic metre (m3).B3"@en ;
                           rdfs:label "effective capacity"@en .


###  http://saref.linkeddata.es/def/bldg#tankEndShapeType
bldg:tankEndShapeType rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Tank ;
                      rdfs:range xsd:string ;
                      rdfs:comment "Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5"@en ;
                      rdfs:label "end shape type"@en .


###  http://saref.linkeddata.es/def/bldg#tankFirstCurvatureRadius
bldg:tankFirstCurvatureRadius rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Tank ;
                              rdfs:range xsd:float ;
                              rdfs:comment " FirstCurvatureRadius should be defined as the base or left side radius of curvature value. Usually measured in millimeters (mm)."@en ;
                              rdfs:label "first curvature radius"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalCapacity
bldg:tankNominalCapacity rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Tank ;
                         rdfs:range xsd:float ;
                         rdfs:comment " The total nominal or design volumetric capacity of the tank. Usually measured in cubic metre (m3)."@en ;
                         rdfs:label "nominal capacity"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalDepth
bldg:tankNominalDepth rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Tank ;
                      rdfs:range xsd:float ;
                      rdfs:comment " The nominal depth of the tank. Note: Not required for a horizontal cylindrical tank. Usually measured in millimeters (mm)."@en ;
                      rdfs:label "nominal depth"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalLengthOrDiameter
bldg:tankNominalLengthOrDiameter rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Tank ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "nominal length or diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalWidthOrDiameter
bldg:tankNominalWidthOrDiameter rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Tank ;
                                rdfs:range xsd:float ;
                                rdfs:comment " The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank. Note: Not required for a vertical cylindrical tank. Usually measured in millimeters (mm)."@en ;
                                rdfs:label "nominal width or diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tankNumberOfSections
bldg:tankNumberOfSections rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Tank ;
                          rdfs:range xsd:integer ;
                          rdfs:comment " Number of sections used in the construction of the tank. Default is 1. Note: All sections assumed to be the same size."@en ;
                          rdfs:label "number of sections"@en .


###  http://saref.linkeddata.es/def/bldg#tankOperatingWight
bldg:tankOperatingWight rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Tank ;
                        rdfs:range xsd:float ;
                        rdfs:comment " Operating weight of the tank including all of its contents. Usually measured in kilograms (kg) or grams (g)."@en ;
                        rdfs:label "operating wight"@en .


###  http://saref.linkeddata.es/def/bldg#tankPatternType
bldg:tankPatternType rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Tank ;
                     rdfs:range xsd:string ;
                     rdfs:comment "Defines the types of pattern (or shape of a tank that may be specified."@en ;
                     rdfs:label "pattern type"@en .


###  http://saref.linkeddata.es/def/bldg#tankSecondCurvatureRadius
bldg:tankSecondCurvatureRadius rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Tank ;
                               rdfs:range xsd:float ;
                               rdfs:comment " SecondCurvatureRadius should be defined as the top or right side radius of curvature value. Usually measured in millimeters (mm)."@en ;
                               rdfs:label "second curvature radius"@en .


###  http://saref.linkeddata.es/def/bldg#tankStorageType
bldg:tankStorageType rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Tank ;
                     rdfs:range xsd:string ;
                     rdfs:comment "Defines the general material category intended to be stored."@en ;
                     rdfs:label "storage type"@en .


###  http://saref.linkeddata.es/def/bldg#transformerImaginaryImpedanceRatio
bldg:transformerImaginaryImpedanceRatio rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Transformer ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment " The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
                                        rdfs:label "imaginary impedance ratio"@en .


###  http://saref.linkeddata.es/def/bldg#transformerIsNeutralPrimaryTerminalAvailable
bldg:transformerIsNeutralPrimaryTerminalAvailable rdf:type owl:DatatypeProperty ;
                                                  rdfs:domain bldg:Transformer ;
                                                  rdfs:range xsd:boolean ;
                                                  rdfs:comment " An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
                                                  rdfs:label "is neutral primary terminal available"@en .


###  http://saref.linkeddata.es/def/bldg#transformerIsNeutralSecondaryTerminalAvailable
bldg:transformerIsNeutralSecondaryTerminalAvailable rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:Transformer ;
                                                    rdfs:range xsd:boolean ;
                                                    rdfs:comment " An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
                                                    rdfs:label "is neutral secondary terminal available"@en .


###  http://saref.linkeddata.es/def/bldg#transformerMaximumApparentPower
bldg:transformerMaximumApparentPower rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Transformer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Maximum apparent power/capacity in VA (volt ampere). Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "maximum apparent power"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryApparentPower
bldg:transformerPrimaryApparentPower rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Transformer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side. Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "primary apparent power"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryCurrent
bldg:transformerPrimaryCurrent rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Transformer ;
                               rdfs:range xsd:float ;
                               rdfs:comment " The current that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Ampere (A)."@en ;
                               rdfs:label "primary current"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryFrequency
bldg:transformerPrimaryFrequency rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Transformer ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The frequency that is going to be transformed and that runs into the transformer on the primary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
                                 rdfs:label "primary frequency"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryVoltage
bldg:transformerPrimaryVoltage rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Transformer ;
                               rdfs:range xsd:float ;
                               rdfs:comment " The voltage that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Volts (V, W/A)."@en ;
                               rdfs:label "primary voltage"@en .


###  http://saref.linkeddata.es/def/bldg#transformerRealImpedanceRatio
bldg:transformerRealImpedanceRatio rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Transformer ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
                                   rdfs:label "real impedance ratio"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryApparentPower
bldg:transformerSecondaryApparentPower rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Transformer ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side. Usually measured in Watts (W, J/s)."@en ;
                                       rdfs:label "secondary apparent power"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryCurrent
bldg:transformerSecondaryCurrent rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Transformer ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The current that has been transformed and is running out of the transformer on the secondary side. Usually measured in Ampere (A)."@en ;
                                 rdfs:label "secondary current"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryCurrentType
bldg:transformerSecondaryCurrentType rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Transformer ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment " A list of the secondary current types that can result from transformer output."@en ;
                                     rdfs:label "secondary current type"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryFrequency
bldg:transformerSecondaryFrequency rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Transformer ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " The frequency that has been transformed and is running out of the transformer on the secondary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
                                   rdfs:label "secondary frequency"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryVoltage
bldg:transformerSecondaryVoltage rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Transformer ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The voltage that has been transformed and is running out of the transformer on the secondary side. Usually measured in Volts (V, W/A)."@en ;
                                 rdfs:label "secondary voltage"@en .


###  http://saref.linkeddata.es/def/bldg#transformerShortCircuitVoltageImaginaryPart
bldg:transformerShortCircuitVoltageImaginaryPart rdf:type owl:DatatypeProperty ;
                                                 rdfs:domain bldg:Transformer ;
                                                 rdfs:range xsd:float ;
                                                 rdfs:comment " A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
                                                 rdfs:label "short circuit voltage imaginary part"@en .


###  http://saref.linkeddata.es/def/bldg#transformerShortCircuitVoltageRealPart
bldg:transformerShortCircuitVoltageRealPart rdf:type owl:DatatypeProperty ;
                                            rdfs:domain bldg:Transformer ;
                                            rdfs:range xsd:float ;
                                            rdfs:comment " A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
                                            rdfs:label "short circuit voltage real part"@en .


###  http://saref.linkeddata.es/def/bldg#transformerTransformerVectorGroup
bldg:transformerTransformerVectorGroup rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Transformer ;
                                       rdfs:range xsd:string ;
                                       rdfs:comment "List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers."@en ;
                                       rdfs:label "transformer vector group"@en .


###  http://saref.linkeddata.es/def/bldg#transportElementCapacityPeople
bldg:transportElementCapacityPeople rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:TransportElement ;
                                    rdfs:range xsd:positiveInteger ;
                                    rdfs:comment " capacity of the transportation element measured in numbers of person."@en ;
                                    rdfs:label "capacity people"@en .


###  http://saref.linkeddata.es/def/bldg#transportElementCapacityWeight
bldg:transportElementCapacityWeight rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:TransportElement ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Capacity of the transport element measured by weight. Usually measured in kilograms (kg) or grams (g)."@en ;
                                    rdfs:label "capacity weight"@en .


###  http://saref.linkeddata.es/def/bldg#transportElementFireExit
bldg:transportElementFireExit rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:TransportElement ;
                              rdfs:range xsd:boolean ;
                              rdfs:comment " Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes."@en ;
                              rdfs:label "fire exit"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleFoulingFactor
bldg:tubeBundleFoulingFactor rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:TubeBundle ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
                             rdfs:label "fouling factor"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleHasTurbulator
bldg:tubeBundleHasTurbulator rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:TubeBundle ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " TRUE if the tube has a turbulator, FALSE if it does not."@en ;
                             rdfs:label "has turbulator"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleHorizontalSpacing
bldg:tubeBundleHorizontalSpacing rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:TubeBundle ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Horizontal spacing between tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "horizontal spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleInLineRowSpacing
bldg:tubeBundleInLineRowSpacing rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:TubeBundle ;
                                rdfs:range xsd:float ;
                                rdfs:comment " In-line tube row spacing. Usually measured in millimeters (mm)."@en ;
                                rdfs:label "in line row spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleInsideDiameter
bldg:tubeBundleInsideDiameter rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:TubeBundle ;
                              rdfs:range xsd:float ;
                              rdfs:comment " Actual inner diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
                              rdfs:label "inside diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleLength
bldg:tubeBundleLength rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:TubeBundle ;
                      rdfs:range xsd:float ;
                      rdfs:comment " Length of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
                      rdfs:label "length"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleNominalDiameter
bldg:tubeBundleNominalDiameter rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:TubeBundle ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Nominal diameter or width of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
                               rdfs:label "nominal diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleNumberOfCircuits
bldg:tubeBundleNumberOfCircuits rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:TubeBundle ;
                                rdfs:range xsd:integer ;
                                rdfs:comment " Number of parallel fluid tube circuits."@en ;
                                rdfs:label "number of circuits"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleNumberOfRows
bldg:tubeBundleNumberOfRows rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:TubeBundle ;
                            rdfs:range xsd:integer ;
                            rdfs:comment " Number of tube rows in the tube bundle assembly."@en ;
                            rdfs:label "number of rows"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleOutsideDiameter
bldg:tubeBundleOutsideDiameter rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:TubeBundle ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Actual outside diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
                               rdfs:label "outside diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleStaggeredRowSpacing
bldg:tubeBundleStaggeredRowSpacing rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:TubeBundle ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Staggered tube row spacing. Usually measured in millimeters (mm)."@en ;
                                   rdfs:label "staggered row spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleThermalConductivity
bldg:tubeBundleThermalConductivity rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:TubeBundle ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
                                   rdfs:label "thermal conductivity"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleVerticalSpacing
bldg:tubeBundleVerticalSpacing rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:TubeBundle ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm)."@en ;
                               rdfs:label "vertical spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleVolumen
bldg:tubeBundleVolumen rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:TubeBundle ;
                       rdfs:range xsd:float ;
                       rdfs:comment " Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3)."@en ;
                       rdfs:label "volumen"@en .


###  http://saref.linkeddata.es/def/bldg#valveCloseOffRating
bldg:valveCloseOffRating rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Valve ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Close off rating. Usually measured in Pascals (Pa, N/m2)."@en ;
                         rdfs:label "close off rating"@en .


###  http://saref.linkeddata.es/def/bldg#valveFlowCoefficient
bldg:valveFlowCoefficient rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Valve ;
                          rdfs:range xsd:float ;
                          rdfs:comment " Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve."@en ;
                          rdfs:label "flow coefficient"@en .


###  http://saref.linkeddata.es/def/bldg#valveSize
bldg:valveSize rdf:type owl:DatatypeProperty ;
               rdfs:domain bldg:Valve ;
               rdfs:range xsd:float ;
               rdfs:comment " The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.). Usually measured in millimeters (mm)."@en ;
               rdfs:label "size"@en .


###  http://saref.linkeddata.es/def/bldg#valveTestPressure
bldg:valveTestPressure rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Valve ;
                       rdfs:range xsd:float ;
                       rdfs:comment " The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2)."@en ;
                       rdfs:label "test pressure"@en .


###  http://saref.linkeddata.es/def/bldg#valveValveMechanism
bldg:valveValveMechanism rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Valve ;
                         rdfs:range xsd:string ;
                         rdfs:comment "The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal."@en ;
                         rdfs:label "valve mechanism"@en .


###  http://saref.linkeddata.es/def/bldg#valveValveOperation
bldg:valveValveOperation rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Valve ;
                         rdfs:range xsd:string ;
                         rdfs:comment "The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve."@en ;
                         rdfs:label "valve operation"@en .


###  http://saref.linkeddata.es/def/bldg#valveValvePattern
bldg:valveValvePattern rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Valve ;
                       rdfs:range xsd:string ;
                       rdfs:comment "The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports."@en ;
                       rdfs:label "valve pattern"@en .


###  http://saref.linkeddata.es/def/bldg#valveWorkingPressure
bldg:valveWorkingPressure rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Valve ;
                          rdfs:range xsd:float ;
                          rdfs:comment " The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2)."@en ;
                          rdfs:label "working pressure"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorHeight
bldg:vibrationIsolatorHeight rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:VibrationIsolator ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Height of the vibration isolator before tha application of load. Usually measured in millimeters (mm)."@en ;
                             rdfs:label "height"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorIsolatorCompressibility
bldg:vibrationIsolatorIsolatorCompressibility rdf:type owl:DatatypeProperty ;
                                              rdfs:domain bldg:VibrationIsolator ;
                                              rdfs:range xsd:float ;
                                              rdfs:comment " The compressibility of the vibration isolator."@en ;
                                              rdfs:label "isolator compressibility"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorIsolatorStaticDeflection
bldg:vibrationIsolatorIsolatorStaticDeflection rdf:type owl:DatatypeProperty ;
                                               rdfs:domain bldg:VibrationIsolator ;
                                               rdfs:range xsd:float ;
                                               rdfs:comment " Static deflection of the vibration isolator. Usually measured in millimeters (mm)."@en ;
                                               rdfs:label "isolator static deflection"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorMaximumSupportedWeight
bldg:vibrationIsolatorMaximumSupportedWeight rdf:type owl:DatatypeProperty ;
                                             rdfs:domain bldg:VibrationIsolator ;
                                             rdfs:range xsd:float ;
                                             rdfs:comment " The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g)."@en ;
                                             rdfs:label "maximum supported weight"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorVibrationTransmissibility
bldg:vibrationIsolatorVibrationTransmissibility rdf:type owl:DatatypeProperty ;
                                                rdfs:domain bldg:VibrationIsolator ;
                                                rdfs:range xsd:float ;
                                                rdfs:comment " the vibration transmissibility percentage."@en ;
                                                rdfs:label "vibration transmissibility"@en .


#################################################################
#    Classes
#################################################################

###  http://saref.linkeddata.es/def/bldg#Actuator
bldg:Actuator rdf:type owl:Class ;
              rdfs:subClassOf bldg:DistributionControlDevice ;
              rdfs:comment "An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion."@en ;
              rdfs:label "Actuator"@en ;
              rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcActuator" .


###  http://saref.linkeddata.es/def/bldg#AirToAirHeatRecovery
bldg:AirToAirHeatRecovery rdf:type owl:Class ;
                          rdfs:subClassOf bldg:EnergyConversionDevice ;
                          rdfs:comment "An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements."@en ;
                          rdfs:label "Air to air heat recovery"@en ;
                          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAirToAirHeatRecovery" .


###  http://saref.linkeddata.es/def/bldg#Alarm
bldg:Alarm rdf:type owl:Class ;
           rdfs:subClassOf bldg:DistributionControlDevice ;
           rdfs:comment """An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device.

Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms."""@en ;
           rdfs:label "Alarm"@en ;
           rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAlarm" .


###  http://saref.linkeddata.es/def/bldg#AudioVisualAppliance
bldg:AudioVisualAppliance rdf:type owl:Class ;
                          rdfs:subClassOf bldg:FlowTerminal ;
                          rdfs:comment """An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video.

Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only."""@en ;
                          rdfs:label "audio visual appliance"@en ;
                          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAudioVisualApplicance" .


###  http://saref.linkeddata.es/def/bldg#Boiler
bldg:Boiler rdf:type owl:Class ;
            rdfs:subClassOf bldg:EnergyConversionDevice ;
            rdfs:comment """\"A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications.

IfcBoiler is a vessel solely used for heating of water or other fluids. Storage vessels, such as for drinking water storage are considered as tanks and use the IfcTank entity.\""""@en ;
            rdfs:label "Boiler"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" .


###  http://saref.linkeddata.es/def/bldg#Building
bldg:Building rdf:type owl:Class ;
              rdfs:subClassOf [ rdf:type owl:Restriction ;
                                owl:onProperty bldg:isComposedBy ;
                                owl:allValuesFrom bldg:BuildingSpace
                              ] ;
              rdfs:label "Building"@en .


###  http://saref.linkeddata.es/def/bldg#BuildingDevice
bldg:BuildingDevice rdf:type owl:Class ;
                    rdfs:subClassOf bldg:BuildingObject ,
                                    bldg:Device ;
                    rdfs:label "Building device"@en .


###  http://saref.linkeddata.es/def/bldg#BuildingObject
bldg:BuildingObject rdf:type owl:Class ;
                    rdfs:label "BuildingObject"@en .


###  http://saref.linkeddata.es/def/bldg#BuildingSpace
bldg:BuildingSpace rdf:type owl:Class ;
                   rdfs:subClassOf [ rdf:type owl:Restriction ;
                                     owl:onProperty bldg:isComponentOf ;
                                     owl:allValuesFrom bldg:Building
                                   ] ;
                   rdfs:label "BuildingSpace"@en .


###  http://saref.linkeddata.es/def/bldg#Burner
bldg:Burner rdf:type owl:Class ;
            rdfs:subClassOf bldg:EnergyConversionDevice ;
            rdfs:comment "A burner is a device that converts fuel into heat through combustion. It includes gas, oil, and wood burners."@en ;
            rdfs:label "Burner"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBurner" .


###  http://saref.linkeddata.es/def/bldg#Chiller
bldg:Chiller rdf:type owl:Class ;
             rdfs:subClassOf bldg:EnergyConversionDevice ;
             rdfs:comment "A chiller is a device used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle to cool a fluid, typically water or a mixture of water and glycol. The chilled fluid is then used to cool and dehumidify air in a building."@en ;
             rdfs:label "Chiller"@en ;
             rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcChiller" .


###  http://saref.linkeddata.es/def/bldg#Coil
bldg:Coil rdf:type owl:Class ;
          rdfs:subClassOf bldg:EnergyConversionDevice ;
          rdfs:comment """A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface.

Coils may also be used for non-airflow cases such as embedded in a floor slab."""@en ;
          rdfs:label "Coil"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoil" .


###  http://saref.linkeddata.es/def/bldg#CommunicationAppliance
bldg:CommunicationAppliance rdf:type owl:Class ;
                            rdfs:subClassOf bldg:FlowTerminal ;
                            rdfs:comment """A communications appliance transmits and receives electronic or digital information as data or sound.

Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
                            rdfs:label "communication appliance"@en ;
                            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCommunicationAppliance" .


###  http://saref.linkeddata.es/def/bldg#Compressor
bldg:Compressor rdf:type owl:Class ;
                rdfs:subClassOf bldg:FlowMovingDevice ;
                rdfs:comment "A compressor is a device that compresses a fluid typically used in a refrigeration circuit."@en ;
                rdfs:label "Compressor"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCompressor" .


###  http://saref.linkeddata.es/def/bldg#Condenser
bldg:Condenser rdf:type owl:Class ;
               rdfs:subClassOf bldg:EnergyConversionDevice ;
               rdfs:comment "A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state."@en ;
               rdfs:label "Condenser"@en ;
               rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCondenser" .


###  http://saref.linkeddata.es/def/bldg#Controller
bldg:Controller rdf:type owl:Class ;
                rdfs:subClassOf bldg:DistributionControlDevice ;
                rdfs:comment """A controller is a device that monitors inputs and controls outputs within a building automation system.

A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller)."""@en ;
                rdfs:label "controller"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcController" .


###  http://saref.linkeddata.es/def/bldg#CooledBeam
bldg:CooledBeam rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again."@en ;
                rdfs:label "Cooled beam"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCooledBeam" .


###  http://saref.linkeddata.es/def/bldg#CoolingTower
bldg:CoolingTower rdf:type owl:Class ;
                  rdfs:subClassOf bldg:EnergyConversionDevice ;
                  rdfs:comment "A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation."@en ;
                  rdfs:label "Cooling tower"@en ;
                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoolingTower" .


###  http://saref.linkeddata.es/def/bldg#Damper
bldg:Damper rdf:type owl:Class ;
            rdfs:subClassOf bldg:FlowController ;
            rdfs:comment "A damper typically participates in an HVAC duct distribution system and is used to control or modulate the flow of air."@en ;
            rdfs:label "Damper"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDamper" .


###  http://saref.linkeddata.es/def/bldg#Device
bldg:Device rdf:type owl:Class ;
            rdfs:subClassOf <https://w3id.org/saref#Device> ;
            rdfs:label "Device"@en .


###  http://saref.linkeddata.es/def/bldg#DistributionControlDevice
bldg:DistributionControlDevice rdf:type owl:Class ;
                               rdfs:subClassOf bldg:DistributionDevice ;
                               rdfs:label "Distribution control device"@en .


###  http://saref.linkeddata.es/def/bldg#DistributionDevice
bldg:DistributionDevice rdf:type owl:Class ;
                        rdfs:subClassOf bldg:BuildingDevice ;
                        rdfs:label "DistributionDevice"@en .


###  http://saref.linkeddata.es/def/bldg#DistributionFlowDevice
bldg:DistributionFlowDevice rdf:type owl:Class ;
                            rdfs:subClassOf bldg:DistributionDevice ;
                            rdfs:label "DistributionFlowDevice"@en .


###  http://saref.linkeddata.es/def/bldg#DuctSilencer
bldg:DuctSilencer rdf:type owl:Class ;
                  rdfs:subClassOf bldg:FlowTreatmentDevice ;
                  rdfs:comment "A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device."@en ;
                  rdfs:label "Duct silencer"@en ;
                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDuctSilencer" .


###  http://saref.linkeddata.es/def/bldg#ElectricAppliance
bldg:ElectricAppliance rdf:type owl:Class ;
                       rdfs:subClassOf bldg:FlowTerminal ;
                       rdfs:comment """An electric appliance is a device intended for consumer usage that is powered by electricity.

Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
                       rdfs:label "electric appliance"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricAppliance" .


###  http://saref.linkeddata.es/def/bldg#ElectricFlowStorageDevice
bldg:ElectricFlowStorageDevice rdf:type owl:Class ;
                               rdfs:subClassOf bldg:FlowStorageDevice ;
                               rdfs:comment "An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released."@en ;
                               rdfs:label "Electric flow storage device"@en ;
                               rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricFlowStorageDevice" .


###  http://saref.linkeddata.es/def/bldg#ElectricGenerator
bldg:ElectricGenerator rdf:type owl:Class ;
                       rdfs:subClassOf bldg:EnergyConversionDevice ;
                       rdfs:comment "An electric generator is an engine that is a machine for converting mechanical energy into electrical energy."@en ;
                       rdfs:label "Electric generator"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricGenerator" .


###  http://saref.linkeddata.es/def/bldg#ElectricMotor
bldg:ElectricMotor rdf:type owl:Class ;
                   rdfs:subClassOf bldg:EnergyConversionDevice ;
                   rdfs:comment "An electric motor is an engine that is a machine for converting electrical energy into mechanical energy."@en ;
                   rdfs:label "Electric motor"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricMotor" .


###  http://saref.linkeddata.es/def/bldg#ElectricTimeControl
bldg:ElectricTimeControl rdf:type owl:Class ;
                         rdfs:subClassOf bldg:FlowController ;
                         rdfs:comment "An electric time control is a device that applies control to the provision or flow of electrical energy over time."@en ;
                         rdfs:label "Electric time control"@en ;
                         rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricTimeControl" .


###  http://saref.linkeddata.es/def/bldg#EnergyConversionDevice
bldg:EnergyConversionDevice rdf:type owl:Class ;
                            rdfs:subClassOf bldg:DistributionFlowDevice ;
                            rdfs:comment "The distribution flow element IfcEnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system. Its type is defined by IfcEnergyConversionDeviceType or its subtypes."@en ;
                            rdfs:label "Energy conversion device"@en ;
                            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEnergyConversionDevice" .


###  http://saref.linkeddata.es/def/bldg#Engine
bldg:Engine rdf:type owl:Class ;
            rdfs:subClassOf bldg:EnergyConversionDevice ;
            rdfs:comment "An engine is a device that converts fuel into mechanical energy through combustion."@en ;
            rdfs:label "Engine"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEngine" .


###  http://saref.linkeddata.es/def/bldg#EvaporativeCooler
bldg:EvaporativeCooler rdf:type owl:Class ;
                       rdfs:subClassOf bldg:EnergyConversionDevice ;
                       rdfs:comment "An evaporative cooler is a device that cools air by saturating it with water vapor."@en ;
                       rdfs:label "Evaporative cooler"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporativeCooler" .


###  http://saref.linkeddata.es/def/bldg#Evaporator
bldg:Evaporator rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid."@en ;
                rdfs:label "Evaporator"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporator" .


###  http://saref.linkeddata.es/def/bldg#Fan
bldg:Fan rdf:type owl:Class ;
         rdfs:subClassOf bldg:FlowMovingDevice ;
         rdfs:comment "A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system."@en ;
         rdfs:label "Fan"@en ;
         rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFan" .


###  http://saref.linkeddata.es/def/bldg#Filter
bldg:Filter rdf:type owl:Class ;
            rdfs:subClassOf bldg:FlowTreatmentDevice ;
            rdfs:comment "A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases."@en ;
            rdfs:label "Filter"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFilter" .


###  http://saref.linkeddata.es/def/bldg#FireSuppressionTerminal
bldg:FireSuppressionTerminal rdf:type owl:Class ;
                             rdfs:subClassOf bldg:FlowTerminal ;
                             rdfs:comment """A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire.

A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire."""@en ;
                             rdfs:label "Fire suppression terminal"@en ;
                             rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFireSuppressionTerminal" .


###  http://saref.linkeddata.es/def/bldg#FlowController
bldg:FlowController rdf:type owl:Class ;
                    rdfs:subClassOf bldg:DistributionFlowDevice ;
                    rdfs:comment "The distribution flow element IfcFlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays. Its type is defined by IfcFlowControllerType or subtypes."@en ;
                    rdfs:label "Flow controller"@en ;
                    rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowController" .


###  http://saref.linkeddata.es/def/bldg#FlowInstrument
bldg:FlowInstrument rdf:type owl:Class ;
                    rdfs:subClassOf bldg:DistributionControlDevice ;
                    rdfs:comment """A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points.

Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.)"""@en ;
                    rdfs:label "flow instrument"@en ;
                    rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowInstrument" .


###  http://saref.linkeddata.es/def/bldg#FlowMeter
bldg:FlowMeter rdf:type owl:Class ;
               rdfs:subClassOf bldg:FlowController ;
               rdfs:comment "A flow meter is a device that is used to measure the flow rate in a system."@en ;
               rdfs:label "Flow meter"@en ;
               rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMeter" .


###  http://saref.linkeddata.es/def/bldg#FlowMovingDevice
bldg:FlowMovingDevice rdf:type owl:Class ;
                      rdfs:subClassOf bldg:DistributionFlowDevice ;
                      rdfs:comment "The distribution flow element IfcFlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system. Its type is defined by IfcFlowMovingDeviceType or its subtypes."@en ;
                      rdfs:label "Flow moving device"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMovingDevice" .


###  http://saref.linkeddata.es/def/bldg#FlowStorageDevice
bldg:FlowStorageDevice rdf:type owl:Class ;
                       rdfs:subClassOf bldg:DistributionFlowDevice ;
                       rdfs:comment "The distribution flow element IfcFlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank). Its type is defined by IfcFlowStorageDeviceType or its subtypes."@en ;
                       rdfs:label "Flow storage device"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowStorageDevice" .


###  http://saref.linkeddata.es/def/bldg#FlowTerminal
bldg:FlowTerminal rdf:type owl:Class ;
                  rdfs:subClassOf bldg:DistributionFlowDevice ;
                  rdfs:comment "The distribution flow element IfcFlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment. Its type is defined by IfcFlowTerminalType or its subtypes."@en ;
                  rdfs:label "Flow terminal"@en ;
                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTerminal" .


###  http://saref.linkeddata.es/def/bldg#FlowTreatmentDevice
bldg:FlowTreatmentDevice rdf:type owl:Class ;
                         rdfs:subClassOf bldg:DistributionFlowDevice ;
                         rdfs:comment "The distribution flow element IfcFlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system. Its type is defined by IfcFlowTreatmentDeviceType or its subtypes."@en ;
                         rdfs:label "Flow treatment device"@en ;
                         rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTreatmentDevice" .


###  http://saref.linkeddata.es/def/bldg#HeatExchanger
bldg:HeatExchanger rdf:type owl:Class ;
                   rdfs:subClassOf bldg:EnergyConversionDevice ;
                   rdfs:comment """A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers.

IfcHeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas IfcAirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air)."""@en ;
                   rdfs:label "Heat exchanger"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHeatExchanger" .


###  http://saref.linkeddata.es/def/bldg#Humidifier
bldg:Humidifier rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "A humidifier is a device that adds moisture into the air."@en ;
                rdfs:label "Humidifier"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHumidifier" .


###  http://saref.linkeddata.es/def/bldg#Interceptor
bldg:Interceptor rdf:type owl:Class ;
                 rdfs:subClassOf bldg:FlowTreatmentDevice ;
                 rdfs:comment "An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity."@en ;
                 rdfs:label "Interceptor"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcInterceptor" .


###  http://saref.linkeddata.es/def/bldg#Lamp
bldg:Lamp rdf:type owl:Class ;
          rdfs:subClassOf bldg:FlowTerminal ;
          rdfs:comment "A lamp is an artificial light source such as a light bulb or tube."@en ;
          rdfs:label "Lamp"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcLamp" .


###  http://saref.linkeddata.es/def/bldg#MedicalDevice
bldg:MedicalDevice rdf:type owl:Class ;
                   rdfs:subClassOf bldg:FlowTerminal ;
                   rdfs:comment "A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide."@en ;
                   rdfs:label "Medical device"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcMedicalDevice" .


###  http://saref.linkeddata.es/def/bldg#Outlet
bldg:Outlet rdf:type owl:Class ;
            rdfs:subClassOf bldg:FlowTerminal ;
            rdfs:comment """An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications.

Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture."""@en ;
            rdfs:label "Outlet"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcOutlet" .


###  http://saref.linkeddata.es/def/bldg#ProtectiveDevice
bldg:ProtectiveDevice rdf:type owl:Class ;
                      rdfs:subClassOf bldg:FlowController ;
                      rdfs:comment """A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded.

A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection."""@en ;
                      rdfs:label "Protective device"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDevice" .


###  http://saref.linkeddata.es/def/bldg#ProtectiveDeviceTrippingUnit
bldg:ProtectiveDeviceTrippingUnit rdf:type owl:Class ;
                                  rdfs:subClassOf bldg:DistributionControlDevice ;
                                  rdfs:comment "A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded."@en ;
                                  rdfs:label "Protective device tripping unit"@en ;
                                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDeviceTrippingUnit" .


###  http://saref.linkeddata.es/def/bldg#Pump
bldg:Pump rdf:type owl:Class ;
          rdfs:subClassOf bldg:FlowMovingDevice ;
          rdfs:comment "A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system."@en ;
          rdfs:label "Pump"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcPump" .


###  http://saref.linkeddata.es/def/bldg#SanitaryTerminal
bldg:SanitaryTerminal rdf:type owl:Class ;
                      rdfs:subClassOf bldg:FlowTerminal ;
                      rdfs:comment "A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal."@en ;
                      rdfs:label "Sanitary terminal"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSanitaryTerminal" .


###  http://saref.linkeddata.es/def/bldg#Sensor
bldg:Sensor rdf:type owl:Class ;
            rdfs:subClassOf bldg:DistributionControlDevice ,
                            <https://w3id.org/saref#Sensor> ;
            rdfs:comment "A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument."@en ;
            rdfs:label "sensor"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSensor" .


###  http://saref.linkeddata.es/def/bldg#ShadingDevice
bldg:ShadingDevice rdf:type owl:Class ;
                   rdfs:subClassOf bldg:BuildingDevice ;
                   rdfs:comment "Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable."@en ;
                   rdfs:label "Shading device"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcShadingDevice" .


###  http://saref.linkeddata.es/def/bldg#SolarDevice
bldg:SolarDevice rdf:type owl:Class ;
                 rdfs:subClassOf bldg:EnergyConversionDevice ;
                 rdfs:comment "A solar device converts solar radiation into other energy such as electric current or thermal energy."@en ;
                 rdfs:label "solar device"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSolarDevice" .


###  http://saref.linkeddata.es/def/bldg#SpaceHeater
bldg:SpaceHeater rdf:type owl:Class ;
                 rdfs:subClassOf bldg:FlowTerminal ;
                 rdfs:comment """Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters.

IfcUnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; IfcCoil should be used for coil-based floor heating."""@en ;
                 rdfs:label "Space heater"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSpaceHeater" .


###  http://saref.linkeddata.es/def/bldg#SwitchingDevice
bldg:SwitchingDevice rdf:type owl:Class ;
                     rdfs:subClassOf bldg:FlowController ;
                     rdfs:comment """A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity.

Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports."""@en ;
                     rdfs:label "Switching device"@en ;
                     rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSwitchingDevice" .


###  http://saref.linkeddata.es/def/bldg#Tank
bldg:Tank rdf:type owl:Class ;
          rdfs:subClassOf bldg:FlowStorageDevice ;
          rdfs:comment "A tank is a vessel or container in which a fluid or gas is stored for later use."@en ;
          rdfs:label "Tank"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTank" .


###  http://saref.linkeddata.es/def/bldg#Transformer
bldg:Transformer rdf:type owl:Class ;
                 rdfs:subClassOf bldg:EnergyConversionDevice ;
                 rdfs:comment """A transformer is an inductive stationary device that transfers electrical energy from one circuit to another.

IfcTransformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: IfcController converts arbitrary signals, IfcAudioVisualAppliance converts signals for audio or video streams, and IfcCommunicationsAppliance converts signals for data or other communications usage."""@en ;
                 rdfs:label "Transformer"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransformer" .


###  http://saref.linkeddata.es/def/bldg#TransportElement
bldg:TransportElement rdf:type owl:Class ;
                      rdfs:subClassOf bldg:Device ;
                      rdfs:comment "A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The IfcTransportElement defines the occurrence of a transport element, that (if given), is expressed by the IfcTransportElementType. "@en ;
                      rdfs:label "Transport element"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransportElement" .


###  http://saref.linkeddata.es/def/bldg#TubeBundle
bldg:TubeBundle rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil."@en ;
                rdfs:label "Tube bundle"@en ;