saref4bldg.ttl 189 KB
Newer Older
1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000


###  http://saref.linkeddata.es/def/bldg#ductSilencerTemperatureRangeMax
bldg:ductSilencerTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:DuctSilencer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable minimum and maximum temperature. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerTemperatureRangeMin
bldg:ductSilencerTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:DuctSilencer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable minimum and maximum temperature. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerWeight
bldg:ductSilencerWeight rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:DuctSilencer ;
                        rdfs:range xsd:float ;
                        rdfs:comment " The weight of the silencer. Usually measured in kilograms (kg) or grams (g)."@en ;
                        rdfs:label "weight"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerWorkingPressureRangeMax
bldg:ductSilencerWorkingPressureRangeMax rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:DuctSilencer ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment "Allowable minimum and maximum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
                                         rdfs:label "working pressure range max"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerWorkingPressureRangeMin
bldg:ductSilencerWorkingPressureRangeMin rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:DuctSilencer ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment "Allowable minimum and maximum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
                                         rdfs:label "working pressure range min"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalFrequency
bldg:electricFlowStorageDeviceNominalFrequency rdf:type owl:DatatypeProperty ;
                                               rdfs:domain bldg:ElectricFlowStorageDevice ;
                                               rdfs:range xsd:float ;
                                               rdfs:comment " The nominal frequency of the supply. Usually measured in cycles/s or Hertz (Hz)."@en ;
                                               rdfs:label "nominal frequency"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltage
bldg:electricFlowStorageDeviceNominalSupplyVoltage rdf:type owl:DatatypeProperty ;
                                                   rdfs:domain bldg:ElectricFlowStorageDevice ;
                                                   rdfs:range xsd:float ;
                                                   rdfs:comment " The nominal voltage of the supply. Usually measured in Volts (V, W/A)."@en ;
                                                   rdfs:label "nominal supply voltage"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltageOffsetMax
bldg:electricFlowStorageDeviceNominalSupplyVoltageOffsetMax rdf:type owl:DatatypeProperty ;
                                                            rdfs:domain bldg:ElectricFlowStorageDevice ;
                                                            rdfs:range xsd:float ;
                                                            rdfs:comment " The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
                                                            rdfs:label "nominal supply voltage offset max"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltageOffsetMin
bldg:electricFlowStorageDeviceNominalSupplyVoltageOffsetMin rdf:type owl:DatatypeProperty ;
                                                            rdfs:domain bldg:ElectricFlowStorageDevice ;
                                                            rdfs:range xsd:float ;
                                                            rdfs:comment " The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
                                                            rdfs:label "nominal supply voltage offset min"@en .


###  http://saref.linkeddata.es/def/bldg#electricGeneratorElectricGeneratorEfficiency
bldg:electricGeneratorElectricGeneratorEfficiency rdf:type owl:DatatypeProperty ;
                                                  rdfs:domain bldg:ElectricGenerator ;
                                                  rdfs:range xsd:float ;
                                                  rdfs:comment " the ratio of output capacity to intake capacity."@en ;
                                                  rdfs:label "electric generator efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#electricGeneratorMaximumPowerOutput
bldg:electricGeneratorMaximumPowerOutput rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:ElectricGenerator ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
                                         rdfs:label "maximum power output"@en .


###  http://saref.linkeddata.es/def/bldg#electricGeneratorStartCurrentFactor
bldg:electricGeneratorStartCurrentFactor rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:ElectricGenerator ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
                                         rdfs:label "start current factor"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorElectricMotorEfficiency
bldg:electricMotorElectricMotorEfficiency rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:ElectricMotor ;
                                          rdfs:range xsd:float ;
                                          rdfs:comment " The ratio of output capacity to intake capacity."@en ;
                                          rdfs:label "electric motor efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorFrameSize
bldg:electricMotorFrameSize rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:ElectricMotor ;
                            rdfs:range xsd:string ;
                            rdfs:comment " Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard."@en ;
                            rdfs:label "frame size"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorHasPartWinding
bldg:electricMotorHasPartWinding rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:ElectricMotor ;
                                 rdfs:range xsd:boolean ;
                                 rdfs:comment " Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) ."@en ;
                                 rdfs:label "has part winding"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorIsGuarded
bldg:electricMotorIsGuarded rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:ElectricMotor ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE)."@en ;
                            rdfs:label "is guarded"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorLockedRotorCurrent
bldg:electricMotorLockedRotorCurrent rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Input current when a motor armature is energized but not rotating. Usually measured in Ampere (A)."@en ;
                                     rdfs:label "locked rotor current"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorMaximumPowerOutput
bldg:electricMotorMaximumPowerOutput rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "maximum power output"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorMotorEnclosureType
bldg:electricMotorMotorEnclosureType rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment " A list of the available types of motor enclosure from which that required may be selected."@en ;
                                     rdfs:label "motor enclosure type"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorStartCurrentFactor
bldg:electricMotorStartCurrentFactor rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
                                     rdfs:label "start current factor"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorStartingTime
bldg:electricMotorStartingTime rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:ElectricMotor ;
                               rdfs:range xsd:float ;
                               rdfs:comment " The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals."@en ;
                               rdfs:label "starting time"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorTeTime
bldg:electricMotorTeTime rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:ElectricMotor ;
                         rdfs:range xsd:float ;
                         rdfs:comment " The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device."@en ;
                         rdfs:label "te time"@en .


###  http://saref.linkeddata.es/def/bldg#engineEnergySource
bldg:engineEnergySource rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Engine ;
                        rdfs:range xsd:string ;
                        rdfs:comment "The source of energy."@en ;
                        rdfs:label "energy source"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerFlowArrangement
bldg:evaporativeCoolerFlowArrangement rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:EvaporativeCooler ;
                                      rdfs:range xsd:string ;
                                      rdfs:comment "CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: Air and water flow enter in same directions."@en ;
                                      rdfs:label "flow arrangement"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerHeatExchangeArea
bldg:evaporativeCoolerHeatExchangeArea rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:EvaporativeCooler ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Heat exchange area. Usually measured in square metre (m2)."@en ;
                                       rdfs:label "heat exchange area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerOperationalTemperatureRangeMax
bldg:evaporativeCoolerOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                                     rdfs:domain bldg:EvaporativeCooler ;
                                                     rdfs:range xsd:float ;
                                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                                     rdfs:label "operational temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerOperationalTemperatureRangeMin
bldg:evaporativeCoolerOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                                     rdfs:domain bldg:EvaporativeCooler ;
                                                     rdfs:range xsd:float ;
                                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                                     rdfs:label "operational temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerWaterRequirement
bldg:evaporativeCoolerWaterRequirement rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:EvaporativeCooler ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Make-up water requirement. Usually measured in m3/s."@en ;
                                       rdfs:label "water requirement"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorEvaporationCoolant
bldg:evaporatorEvaporationCoolant rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Evaporator ;
                                  rdfs:range xsd:string ;
                                  rdfs:comment "The fluid used for the coolant in the evaporator."@en ;
                                  rdfs:label "evaporation coolant"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorEvaporationMediumType
bldg:evaporatorEvaporationMediumType rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Evaporator ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment "ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant."@en ;
                                     rdfs:label "evaporation medium type"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorExternalSurfaceArea
bldg:evaporatorExternalSurfaceArea rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Evaporator ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " External surface area (both primary and secondary area). Usually measured in square metre (m2)."@en ;
                                   rdfs:label "external surface area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorInternalRefrigerantVolume
bldg:evaporatorInternalRefrigerantVolume rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:Evaporator ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " Internal volume of evaporator (refrigerant side). Usually measured in cubic metre (m3)."@en ;
                                         rdfs:label "internal refrigerant volume"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorInternalSurfaceArea
bldg:evaporatorInternalSurfaceArea rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Evaporator ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Internal surface area. Usually measured in square metre (m2)."@en ;
                                   rdfs:label "internal surface area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorInternalWaterVolume
bldg:evaporatorInternalWaterVolume rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Evaporator ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Internal volume of evaporator (water side). Usually measured in cubic metre (m3)."@en ;
                                   rdfs:label "internal water volume"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorNominalHeatTransferArea
bldg:evaporatorNominalHeatTransferArea rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Evaporator ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2)."@en ;
                                       rdfs:label "nominal heat transfer area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorNominalHeatTransferCoefficient
bldg:evaporatorNominalHeatTransferCoefficient rdf:type owl:DatatypeProperty ;
                                              rdfs:domain bldg:Evaporator ;
                                              rdfs:range xsd:float ;
                                              rdfs:comment " Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin."@en ;
                                              rdfs:label "nominal heat transfer coefficient"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorRefrigerantClass
bldg:evaporatorRefrigerantClass rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Evaporator ;
                                rdfs:range xsd:string ;
                                rdfs:comment " Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
                                rdfs:label "refrigerant class"@en .


###  http://saref.linkeddata.es/def/bldg#fanCapacityControlType
bldg:fanCapacityControlType rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Fan ;
                            rdfs:range xsd:string ;
                            rdfs:comment "InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper."@en ;
                            rdfs:label "capacity control type"@en .


###  http://saref.linkeddata.es/def/bldg#fanMotorDriveType
bldg:fanMotorDriveType rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Fan ;
                       rdfs:range xsd:string ;
                       rdfs:comment "Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type. "@en ;
                       rdfs:label "motor drive type"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalAirFlowRate
bldg:fanNominalAirFlowRate rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Fan ;
                           rdfs:range xsd:float ;
                           rdfs:comment " Nominal air flow rate. Usually measured in m3/s."@en ;
                           rdfs:label "nominal air flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalPowerRate
bldg:fanNominalPowerRate rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Fan ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Nominal fan power rate.Usually measured in Watts (W, J/s)."@en ;
                         rdfs:label "nominal power rate"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalRotationSpeed
bldg:fanNominalRotationSpeed rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Fan ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Nominal fan wheel speed. Usually measured in cycles/s."@en ;
                             rdfs:label "nominal rotation speed"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalStaticPressure
bldg:fanNominalStaticPressure rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Fan ;
                              rdfs:range xsd:float ;
                              rdfs:comment " The static pressure within the air stream that the fan must overcome to insure designed circulation of air. Usually measured in Pascals (Pa, N/m2)."@en ;
                              rdfs:label "nominal static pressure"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalTotalPressure
bldg:fanNominalTotalPressure rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Fan ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Nominal total pressure rise across the fan. Usually measured in Pascals (Pa, N/m2)."@en ;
                             rdfs:label "nominal total pressure"@en .


###  http://saref.linkeddata.es/def/bldg#fanOperationTemperatureRangeMax
bldg:fanOperationTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Fan ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "operation temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#fanOperationTemperatureRangeMin
bldg:fanOperationTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Fan ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "operation temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#fanOperationalRiterial
bldg:fanOperationalRiterial rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Fan ;
                            rdfs:range xsd:float ;
                            rdfs:comment " Time of operation at maximum operational ambient air temperature. Measured in seconds (s) or days (d) or other units of time."@en ;
                            rdfs:label "operational riterial"@en .


###  http://saref.linkeddata.es/def/bldg#filterFinalResistance
bldg:filterFinalResistance rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Filter ;
                           rdfs:range xsd:float ;
                           rdfs:comment " Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
                           rdfs:label "final resistance"@en .


###  http://saref.linkeddata.es/def/bldg#filterFlowRateRangeMax
bldg:filterFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Filter ;
                            rdfs:range xsd:float ;
                            rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
                            rdfs:label "flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#filterFlowRateRangeMin
bldg:filterFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Filter ;
                            rdfs:range xsd:float ;
                            rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
                            rdfs:label "flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#filterInitialResistance
bldg:filterInitialResistance rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Filter ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
                             rdfs:label "initial resistance"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalFilterFaceVelocity
bldg:filterNominalFilterFaceVelocity rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Filter ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Filter face velocity. Usually measured in m/s."@en ;
                                     rdfs:label "nominal filter face velocity"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalFlowRate
bldg:filterNominalFlowRate rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Filter ;
                           rdfs:range xsd:float ;
                           rdfs:comment " Nominal fluid flow rate through the filter. Usually measured in m3/s."@en ;
                           rdfs:label "nominal flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalMediaSurfaceVelocity
bldg:filterNominalMediaSurfaceVelocity rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Filter ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Average fluid velocity at the media surface. Usually measured in m/s."@en ;
                                       rdfs:label "nominal media surface velocity"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalParticleGeometricMeanDiameter
bldg:filterNominalParticleGeometricMeanDiameter rdf:type owl:DatatypeProperty ;
                                                rdfs:domain bldg:Filter ;
                                                rdfs:range xsd:float ;
                                                rdfs:comment " Particle geometric mean diameter associated with nominal efficiency. Usually measured in millimeters (mm)."@en ;
                                                rdfs:label "nominal particle geometric mean diameter"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalParticleGeometricStandardDeviation
bldg:filterNominalParticleGeometricStandardDeviation rdf:type owl:DatatypeProperty ;
                                                     rdfs:domain bldg:Filter ;
                                                     rdfs:range xsd:float ;
                                                     rdfs:comment " Particle geometric standard deviation associated with nominal efficiency. "@en ;
                                                     rdfs:label "nominal particle geometric standard deviation"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalPressureDrop
bldg:filterNominalPressureDrop rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Filter ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Total pressure drop across the filter. Usually measured in Pascals (Pa, N/m2)."@en ;
                               rdfs:label "nominal pressure drop"@en .


###  http://saref.linkeddata.es/def/bldg#filterOperationTemperatureRangeMax
bldg:filterOperationTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Filter ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment "Allowable operation ambient fluid temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                        rdfs:label "operation temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#filterOperationTemperatureRangeMin
bldg:filterOperationTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Filter ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment "Allowable operation ambient fluid temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                        rdfs:label "operation temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#filterWeight
bldg:filterWeight rdf:type owl:DatatypeProperty ;
                  rdfs:domain bldg:Filter ;
                  rdfs:range xsd:float ;
                  rdfs:comment " Weight of filter. Usually measured in kilograms (kg) or grams (g)."@en ;
                  rdfs:label "weight"@en .


###  http://saref.linkeddata.es/def/bldg#flowMeterReadOutType
bldg:flowMeterReadOutType rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:FlowMeter ;
                          rdfs:range xsd:string ;
                          rdfs:comment "Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer."@en ;
                          rdfs:label "read out type"@en .


###  http://saref.linkeddata.es/def/bldg#flowMeterRemoteReading
bldg:flowMeterRemoteReading rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:FlowMeter ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE)."@en ;
                            rdfs:label "remote reading"@en .


###  http://saref.linkeddata.es/def/bldg#heatExchangerArrangement
bldg:heatExchangerArrangement rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:HeatExchanger ;
                              rdfs:range xsd:string ;
                              rdfs:comment "Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above."@en ;
                              rdfs:label "arrangement"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierApplication
bldg:humidifierApplication rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Humidifier ;
                           rdfs:range xsd:string ;
                           rdfs:comment "Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system."@en ;
                           rdfs:label "application"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierInternalControl
bldg:humidifierInternalControl rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Humidifier ;
                               rdfs:range xsd:string ;
                               rdfs:comment "Internal modulation control."@en ;
                               rdfs:label "internal control"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierNominalAirFlowRate
bldg:humidifierNominalAirFlowRate rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Humidifier ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Nominal rate of air flow into which water vapor is added. Usually measured in m3/s."@en ;
                                  rdfs:label "nominal air flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierNominalMoistureGain
bldg:humidifierNominalMoistureGain rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Humidifier ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Nominal rate of water vapor added into the airstream. Usually measured in kg/s."@en ;
                                   rdfs:label "nominal moisture gain"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierWaterRequirement
bldg:humidifierWaterRequirement rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Humidifier ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Make-up water requirement. Usually measured in m3/s."@en ;
                                rdfs:label "water requirement"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierWeight
bldg:humidifierWeight rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Humidifier ;
                      rdfs:range xsd:float ;
                      rdfs:comment " The weight of the humidifier. Usually measured in kilograms (kg) or grams (g)."@en ;
                      rdfs:label "weight"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorCoverLength
bldg:interceptorCoverLength rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Interceptor ;
                            rdfs:range xsd:float ;
                            rdfs:comment " The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
                            rdfs:label "cover length"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorCoverWidth
bldg:interceptorCoverWidth rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Interceptor ;
                           rdfs:range xsd:float ;
                           rdfs:comment " The length measured along the x-axis in the local coordinate system of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
                           rdfs:label "cover width"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorInletConnectionSize
bldg:interceptorInletConnectionSize rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Interceptor ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Size of the inlet connection. Usually measured in millimeters (mm)."@en ;
                                    rdfs:label "inlet connection size"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorNominalBodyDepth
bldg:interceptorNominalBodyDepth rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Interceptor ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Nominal or quoted =length, measured along the z-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "nominal body depth"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorNominalBodyLength
bldg:interceptorNominalBodyLength rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Interceptor ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Nominal or quoted length, measured along the x-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
                                  rdfs:label "nominal body length"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorNominalBodyWidth
bldg:interceptorNominalBodyWidth rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Interceptor ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Nominal or quoted length, measured along the y-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "nominal body width"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorOutletConnectionSize
bldg:interceptorOutletConnectionSize rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Interceptor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Size of the outlet connection. Usually measured in millimeters (mm)."@en ;
                                     rdfs:label "outlet connection size"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorVentilatingPipeSize
bldg:interceptorVentilatingPipeSize rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Interceptor ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Size of the ventilating pipe(s). Usually measured in millimeters (mm)."@en ;
                                    rdfs:label "ventilating pipe size"@en .


###  http://saref.linkeddata.es/def/bldg#lampColorAppearance
bldg:lampColorAppearance rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Lamp ;
                         rdfs:range xsd:string ;
                         rdfs:comment " In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance."@en ;
                         rdfs:label "color appearance"@en .


###  http://saref.linkeddata.es/def/bldg#lampColorRenderingIndex
bldg:lampColorRenderingIndex rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Lamp ;
                             rdfs:range xsd:integer ;
                             rdfs:comment " The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties."@en ;
                             rdfs:label "color rendering index"@en .


###  http://saref.linkeddata.es/def/bldg#lampColorTempeature
bldg:lampColorTempeature rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Lamp ;
                         rdfs:range xsd:float ;
                         rdfs:comment " The color temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate color temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The color temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight). Usually measured in degrees Kelvin (K)."@en ;
                         rdfs:label "color tempeature"@en .


###  http://saref.linkeddata.es/def/bldg#lampContributedLuminousFlux
bldg:lampContributedLuminousFlux rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Lamp ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp. Usually measured in Lumen (lm, Candela Steradian)."@en ;
                                 rdfs:label "contributed luminous flux"@en .


###  http://saref.linkeddata.es/def/bldg#lampLampBallastType
bldg:lampLampBallastType rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Lamp ;
                         rdfs:range xsd:string ;
                         rdfs:comment " The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz)."@en ;
                         rdfs:label "lamp ballast type"@en .


###  http://saref.linkeddata.es/def/bldg#lampLampCompensationType
bldg:lampLampCompensationType rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Lamp ;
                              rdfs:range xsd:string ;
                              rdfs:comment " Identifies the form of compensation used for power factor correction and radio suppression."@en ;
                              rdfs:label "lamp compensation type"@en .


###  http://saref.linkeddata.es/def/bldg#lampLampMaintenanceFactor
bldg:lampLampMaintenanceFactor rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Lamp ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Non recoverable losses of luminous flux of a lamp due to lamp depreciation i.e. the decreasing of light output of a luminaire due to aging and dirt."@en ;
                               rdfs:label "lamp maintenance factor"@en .


###  http://saref.linkeddata.es/def/bldg#lampLightEmitterNominalPower
bldg:lampLightEmitterNominalPower rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Lamp ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Light emitter nominal power. Usually measured in Watts (W, J/s)."@en ;
                                  rdfs:label "light emitter nominal power"@en .


###  http://saref.linkeddata.es/def/bldg#lampSpectrumMax
bldg:lampSpectrumMax rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Lamp ;
                     rdfs:range xsd:float ;
                     rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
                     rdfs:label "spectrum max"@en .


###  http://saref.linkeddata.es/def/bldg#lampSpectrumMin
bldg:lampSpectrumMin rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Lamp ;
                     rdfs:range xsd:float ;
                     rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
                     rdfs:label "spectrum min"@en .


###  http://saref.linkeddata.es/def/bldg#outletIsPluggableOutlet
bldg:outletIsPluggableOutlet rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Outlet ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN)."@en ;
                             rdfs:label "is pluggable outlet"@en .


###  http://saref.linkeddata.es/def/bldg#outletNumberOsSockets
bldg:outletNumberOsSockets rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Outlet ;
                           rdfs:range xsd:integer ;
                           rdfs:comment " The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence."@en ;
                           rdfs:label "number os sockets"@en .


###  http://saref.linkeddata.es/def/bldg#protectiveDeviceTrippingUnitLimitingTerminalSize
bldg:protectiveDeviceTrippingUnitLimitingTerminalSize rdf:type owl:DatatypeProperty ;
                                                      rdfs:domain bldg:ProtectiveDeviceTrippingUnit ;
                                                      rdfs:range xsd:float ;
                                                      rdfs:comment " The maximum terminal size capacity of the device. Usually measured in square metre (m2)."@en ;
                                                      rdfs:label "limiting terminal size"@en .


###  http://saref.linkeddata.es/def/bldg#protectiveDeviceTrippingUnitStandard
bldg:protectiveDeviceTrippingUnitStandard rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:ProtectiveDeviceTrippingUnit ;
                                          rdfs:range xsd:string ;
                                          rdfs:comment " the designation of the Standard applicable for the definition of the characteristics of the tripping_unit."@en ;
                                          rdfs:label "standard"@en .


###  http://saref.linkeddata.es/def/bldg#pumpConnectionSize
bldg:pumpConnectionSize rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Pump ;
                        rdfs:range xsd:float ;
                        rdfs:comment " The connection size of the to and from the pump. Usually measured in millimeters (mm)."@en ;
                        rdfs:label "connection size"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowRateRangeMax
bldg:pumpFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Pump ;
                          rdfs:range xsd:float ;
                          rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
                          rdfs:label "flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowRateRangeMin
bldg:pumpFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Pump ;
                          rdfs:range xsd:float ;
                          rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
                          rdfs:label "flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowResistanceRangeMax
bldg:pumpFlowResistanceRangeMax rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Pump ;
                                rdfs:range xsd:float ;
                                rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
                                rdfs:label "flow resistance range max"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowResistanceRangeMin
bldg:pumpFlowResistanceRangeMin rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Pump ;
                                rdfs:range xsd:float ;
                                rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
                                rdfs:label "flow resistance range min"@en .


###  http://saref.linkeddata.es/def/bldg#pumpNetPositiveSuctionHead
bldg:pumpNetPositiveSuctionHead rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Pump ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Minimum liquid pressure at the pump inlet to prevent cavitation. Usually measured in Pascals (Pa, N/m2)."@en ;
                                rdfs:label "net positive suction head"@en .


###  http://saref.linkeddata.es/def/bldg#pumpNomminalRotationSpeed
bldg:pumpNomminalRotationSpeed rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Pump ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Pump rotational speed under nominal conditions. Usually measured in cycles/s."@en ;
                               rdfs:label "nomminal rotation speed"@en .


###  http://saref.linkeddata.es/def/bldg#pumpTemperatureRangeMax
bldg:pumpTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Pump ;
                             rdfs:range xsd:float ;
                             rdfs:comment "Allowable operational range of the fluid temperature. Usually measured in degrees Kelvin (K)."@en ;
                             rdfs:label "temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#pumpTemperatureRangeMin
bldg:pumpTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Pump ;
                             rdfs:range xsd:float ;
                             rdfs:comment "Allowable operational range of the fluid temperature. Usually measured in degrees Kelvin (K)."@en ;
                             rdfs:label "temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceIsExternal
bldg:shadingDeviceIsExternal rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:ShadingDevice ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building."@en ;
                             rdfs:label "is external"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceMechanicalOperated
bldg:shadingDeviceMechanicalOperated rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ShadingDevice ;
                                     rdfs:range xsd:boolean ;
                                     rdfs:comment " Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE)."@en ;
                                     rdfs:label "mechanical operated"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceRoughness
bldg:shadingDeviceRoughness rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:ShadingDevice ;
                            rdfs:range xsd:string ;
                            rdfs:comment " A measure of the vertical deviations of the surface."@en ;
                            rdfs:label "roughness"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceShadingDeviceType
bldg:shadingDeviceShadingDeviceType rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:ShadingDevice ;
                                    rdfs:range xsd:string ;
                                    rdfs:comment " Specifies the type of shading device."@en ;
                                    rdfs:label "shading device type"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceSolarReflectance
bldg:shadingDeviceSolarReflectance rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:ShadingDevice ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " (Rsol): The ratio of incident solar radiation that is reflected by a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
                                   rdfs:label "solar reflectance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceSolarTransmittance
bldg:shadingDeviceSolarTransmittance rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ShadingDevice ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " (Tsol) The ratio of incident solar radiation that directly passes through a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
                                     rdfs:label "solar transmittance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceThermalTransmittance
bldg:shadingDeviceThermalTransmittance rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:ShadingDevice ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " IfcThermalTransmittanceMeasure is a measure of the rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin."@en ;
                                       rdfs:label "thermal transmittance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceVisibleLightReflectance
bldg:shadingDeviceVisibleLightReflectance rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:ShadingDevice ;
                                          rdfs:range xsd:float ;
                                          rdfs:comment " Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit."@en ;
                                          rdfs:label "visible light reflectance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceVisibleLightTransmittance
bldg:shadingDeviceVisibleLightTransmittance rdf:type owl:DatatypeProperty ;
                                            rdfs:domain bldg:ShadingDevice ;
                                            rdfs:range xsd:float ;
                                            rdfs:comment " Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit."@en ;
                                            rdfs:label "visible light transmittance"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterBodyMass
bldg:spaceHeaterBodyMass rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:SpaceHeater ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Overall body mass of the heater. Usually measured in kilograms (kg) or grams (g)."@en ;
                         rdfs:label "body mass"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterEnergySource
bldg:spaceHeaterEnergySource rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:SpaceHeater ;
                             rdfs:range xsd:string ;
                             rdfs:comment "Enumeration defining the energy source or fuel combusted to generate heat if applicable. Note: hydronic heaters shall use UNSET, dual-use hydronic/electric heaters shall use ELECTRICITY."@en ;
                             rdfs:label "energy source"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterHeatTransferDimension
bldg:spaceHeaterHeatTransferDimension rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:SpaceHeater ;
                                      rdfs:range xsd:string ;
                                      rdfs:comment "Indicates how heat is transmitted according to the shape of the space heater."@en ;
                                      rdfs:label "heat transfer dimension"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterHeatTransferMedium
bldg:spaceHeaterHeatTransferMedium rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:SpaceHeater ;
                                   rdfs:range xsd:string ;
                                   rdfs:comment "Enumeration defining the heat transfer medium if applicable."@en ;
                                   rdfs:label "heat transfer medium"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterNumberOfPanels
bldg:spaceHeaterNumberOfPanels rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:SpaceHeater ;
                               rdfs:range xsd:integer ;
                               rdfs:comment " Number of panels."@en ;
                               rdfs:label "number of panels"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterNumberOfSections
bldg:spaceHeaterNumberOfSections rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:SpaceHeater ;
                                 rdfs:range xsd:integer ;
                                 rdfs:comment " Number of vertical sections, measured in the direction of flow."@en ;
                                 rdfs:label "number of sections"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterOutputCapacity
bldg:spaceHeaterOutputCapacity rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:SpaceHeater ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Total nominal heat output as listed by the manufacturer. Usually measured in Watts (W, J/s)."@en ;
                               rdfs:label "output capacity"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterPlacementType
bldg:spaceHeaterPlacementType rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:SpaceHeater ;
                              rdfs:range xsd:string ;
                              rdfs:comment "Indicates how the space heater is designed to be placed. "@en ;
                              rdfs:label "placement type"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterTemperatureClassification
bldg:spaceHeaterTemperatureClassification rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:SpaceHeater ;
                                          rdfs:range xsd:string ;
                                          rdfs:comment "Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam."@en ;
                                          rdfs:label "temperature classification"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterThermalEfficiency
bldg:spaceHeaterThermalEfficiency rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:SpaceHeater ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input."@en ;
                                  rdfs:label "thermal efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterThermalMassHeatCapacity
bldg:spaceHeaterThermalMassHeatCapacity rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:SpaceHeater ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment " Product of component mass and specific heat."@en ;
                                        rdfs:label "thermal mass heat capacity"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceHasLock
bldg:switchingDeviceHasLock rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:SwitchingDevice ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE)."@en ;
                            rdfs:label "has lock"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceIsIlluminated
bldg:switchingDeviceIsIlluminated rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:SwitchingDevice ;
                                  rdfs:range xsd:boolean ;
                                  rdfs:comment " An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE)."@en ;
                                  rdfs:label "is illuminated"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceLegend
bldg:switchingDeviceLegend rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:SwitchingDevice ;
                           rdfs:range xsd:string ;
                           rdfs:comment " A text inscribed or applied to the switch as a legend to indicate purpose or function."@en ;
                           rdfs:label "legend"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceNumberOfGangs
bldg:switchingDeviceNumberOfGangs rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:SwitchingDevice ;
                                  rdfs:range xsd:integer ;
                                  rdfs:comment " Number of gangs/buttons on this switch."@en ;
                                  rdfs:label "number of gangs"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceSwitchFunction
bldg:switchingDeviceSwitchFunction rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:SwitchingDevice ;
                                   rdfs:range xsd:string ;
                                   rdfs:comment "Indicates types of switches which differs in functionality."@en ;
                                   rdfs:label "switch function"@en .