<http://saref.linkeddata.es/def/bldg> rdf:type owl:Ontology ;
                                       owl:versionIRI <http://saref.linkeddata.es/def/v1/bldg> ;
Raul Garcia-Castro's avatar
Raul Garcia-Castro committed
                                       owl:versionInfo "1.0" ;
                                       dcterms:creator <http://purl.org/net/mpoveda> ,
                                                       <http://www.garcia-castro.com/foaf.rdf#me> ;
                                       vann:preferredNamespacePrefix "saref4bldg" ;
                                       dcterms:license <http://purl.org/NET/rdflicense/cc-by4.0> ;
                                       dc:title "SAREF extension for building devices"@en ;
Raul Garcia-Castro's avatar
Raul Garcia-Castro committed
                                       vann:preferredNamespaceUri "http://saref.linkeddata.es/def/bldg#" ;
                                       rdfs:comment "This ontology extends the SAREF ontology for the building domain by defining building devices and how they are located in a building. This extension is based on the ISO 16739:2013 Industry Foundation Classes (IFC) standard for data sharing in the construction and facility management industries."@en ;
                                       dc:publisher <http://www.oeg-upm.net/> .

#################################################################
#    Annotation properties
#################################################################

###  http://purl.org/dc/terms/creator
dcterms:creator rdf:type owl:AnnotationProperty .


###  http://purl.org/dc/terms/dateCopyrighted
dcterms:dateCopyrighted rdf:type owl:AnnotationProperty .


###  http://purl.org/dc/terms/rightsHolder
dcterms:rightsHolder rdf:type owl:AnnotationProperty .


###  http://purl.org/vocab/vann/preferredNamespacePrefix
vann:preferredNamespacePrefix rdf:type owl:AnnotationProperty .


###  http://purl.org/vocab/vann/preferredNamespaceUri
vann:preferredNamespaceUri rdf:type owl:AnnotationProperty .


#################################################################
#    Datatypes
#################################################################

###  http://www.w3.org/2001/XMLSchema#duration
xsd:duration rdf:type rdfs:Datatype .


#################################################################
#    Object Properties
#################################################################

###  http://saref.linkeddata.es/def/bldg#isComponentOf
bldg:isComponentOf rdf:type owl:ObjectProperty ;
                   rdfs:label "isComponentOf"@en .


###  http://saref.linkeddata.es/def/bldg#isComposedBy
bldg:isComposedBy rdf:type owl:ObjectProperty ;
                  rdfs:label "isComposedBy"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceSetPoint
bldg:switchingDeviceSetPoint rdf:type owl:ObjectProperty ;
                             rdfs:domain bldg:SwitchingDevice ;
                             rdfs:range rdfs:Resource ;
                             rdfs:comment " Indicates the setpoint and label. For toggle switches, there are two positions, 0 for off and 1 for on. For dimmer switches, the values may indicate the fully-off and full-on positions, where missing integer values in between are interpolated. For selector switches, the range indicates the available positions. An IfcTable may be attached (using IfcMetric and IfcPropertyConstraintRelationship) containing columns of the specified header names and types: 'Position' (IfcInteger): The discrete setpoint level. 'Sink' (IfcLabel): The Name of the switched input port (IfcDistributionPort with FlowDirection=SINK). 'Source' (IfcLabel): The Name of the switched output port (IfcDistributionPort with FlowDirection=SOURCE). 'Ratio' (IfcNormalizedRatioMeasure): The ratio of power at the setpoint where 0.0 is off and 1.0 is fully on."@en ;
                             rdfs:label "set point"@en .
77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042


#################################################################
#    Data properties
#################################################################

###  http://saref.linkeddata.es/def/bldg#actuatorFailPosition
bldg:actuatorFailPosition rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Actuator ;
                          rdfs:range xsd:string ;
                          rdfs:comment " Specifies the required fail-safe position of the actuator."@en ;
                          rdfs:label "fail position"@en .


###  http://saref.linkeddata.es/def/bldg#actuatorManualOverride
bldg:actuatorManualOverride rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Actuator ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator."@en ;
                            rdfs:label "manual override"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryHasDefrost
bldg:airToAirHeatRecoveryHasDefrost rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:AirToAirHeatRecovery ;
                                    rdfs:range xsd:boolean ;
                                    rdfs:comment " has the heat exchanger has defrost function or not."@en ;
                                    rdfs:label "has defrost"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryHeatTransferTypeEnum
bldg:airToAirHeatRecoveryHeatTransferTypeEnum rdf:type owl:DatatypeProperty ;
                                              rdfs:domain bldg:AirToAirHeatRecovery ;
                                              rdfs:range xsd:string ;
                                              rdfs:comment "Type of heat transfer between the two air streams."@en ;
                                              rdfs:label "heat transfer type enum"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryOperationalTemperatureRangeMax
bldg:airToAirHeatRecoveryOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                                        rdfs:domain bldg:AirToAirHeatRecovery ;
                                                        rdfs:range xsd:float ;
                                                        rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                                        rdfs:label "operational temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryOperationalTemperatureRangeMin
bldg:airToAirHeatRecoveryOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                                        rdfs:domain bldg:AirToAirHeatRecovery ;
                                                        rdfs:range xsd:float ;
                                                        rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                                        rdfs:label "operational temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryPrimaryAirFlowRateRangeMax
bldg:airToAirHeatRecoveryPrimaryAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:AirToAirHeatRecovery ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment "possible range of primary airflow that can be delivered. Usually measured in m3/s."@en ;
                                                    rdfs:label "primary air flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryPrimaryAirFlowRateRangeMin
bldg:airToAirHeatRecoveryPrimaryAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:AirToAirHeatRecovery ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment "possible range of primary airflow that can be delivered. Usually measured in m3/s."@en ;
                                                    rdfs:label "primary air flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoverySecondaryAirFlowRateRangeMax
bldg:airToAirHeatRecoverySecondaryAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                                                      rdfs:domain bldg:AirToAirHeatRecovery ;
                                                      rdfs:range xsd:float ;
                                                      rdfs:comment "possible range of secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2)."@en ;
                                                      rdfs:label "secondary air flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#airToAirHeatRecoverySecondaryAirFlowRateRangeMin
bldg:airToAirHeatRecoverySecondaryAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                                                      rdfs:domain bldg:AirToAirHeatRecovery ;
                                                      rdfs:range xsd:float ;
                                                      rdfs:comment "possible range of secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2)."@en ;
                                                      rdfs:label "secondary air flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#audioVisualApplianceAudioVolume
bldg:audioVisualApplianceAudioVolume rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:AudioVisualAppliance ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Indicates discrete audio volume levels and corresponding sound power offsets, if applicable. Missing values may be interpolated. Measured in watts."@en ;
                                     rdfs:label "audio volume"@en .


###  http://saref.linkeddata.es/def/bldg#audioVisualApplianceMediaSource
bldg:audioVisualApplianceMediaSource rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:AudioVisualAppliance ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment " Indicates media sources and corresponding names of ports (IfcDistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (IfcAudioVisualAppliance)."@en ;
                                     rdfs:label "media source"@en .


###  http://saref.linkeddata.es/def/bldg#boilerEnergySource
bldg:boilerEnergySource rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Boiler ;
                        rdfs:range xsd:string ;
                        rdfs:comment "Enumeration defining the energy source or fuel cumbusted to generate heat."@en ;
                        rdfs:label "energy source"@en .


###  http://saref.linkeddata.es/def/bldg#boilerHeatTransferSurfaceArea
bldg:boilerHeatTransferSurfaceArea rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Boiler ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Total heat transfer area of the vessel. Usually measured in square metre (m2)."@en ;
                                   rdfs:label "heat transfer surface area"@en .


###  http://saref.linkeddata.es/def/bldg#boilerIsWaterStorageHeater
bldg:boilerIsWaterStorageHeater rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Boiler ;
                                rdfs:range xsd:boolean ;
                                rdfs:comment " This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater."@en ;
                                rdfs:label "is water storage heater"@en .


###  http://saref.linkeddata.es/def/bldg#boilerNominalEnergyConsumption
bldg:boilerNominalEnergyConsumption rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Boiler ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Nominal fuel consumption rate required to produce the total boiler heat output. Usually measured in Watts (W, J/s)."@en ;
                                    rdfs:label "nominal energy consumption"@en .


###  http://saref.linkeddata.es/def/bldg#boilerNominalPartLoadRatioMax
bldg:boilerNominalPartLoadRatioMax rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Boiler ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment "Allowable part load ratio range."@en ;
                                   rdfs:label "nominal part load ratio max"@en .


###  http://saref.linkeddata.es/def/bldg#boilerNominalPartLoadRatioMin
bldg:boilerNominalPartLoadRatioMin rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Boiler ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment "Allowable part load ratio range."@en ;
                                   rdfs:label "nominal part load ratio min"@en .


###  http://saref.linkeddata.es/def/bldg#boilerOperatingMode
bldg:boilerOperatingMode rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Boiler ;
                         rdfs:range xsd:string ;
                         rdfs:comment " Identifies the operating mode of the boiler."@en ;
                         rdfs:label "operating mode"@en .


###  http://saref.linkeddata.es/def/bldg#boilerOutletTemperatureRangeMax
bldg:boilerOutletTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Boiler ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "outlet temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#boilerOutletTemperatureRangeMin
bldg:boilerOutletTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Boiler ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "outlet temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#boilerPressureRating
bldg:boilerPressureRating rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Boiler ;
                          rdfs:range xsd:float ;
                          rdfs:comment " Nominal pressure rating of the boiler as rated by the agency having jurisdiction. Usually measured in Pascals (Pa, N/m2)."@en ;
                          rdfs:label "pressure rating"@en .


###  http://saref.linkeddata.es/def/bldg#boilerWaterInletTemperatureRangeMax
bldg:boilerWaterInletTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:Boiler ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                         rdfs:label "water inlet temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#boilerWaterInletTemperatureRangeMin
bldg:boilerWaterInletTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:Boiler ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                         rdfs:label "water inlet temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#boilerWaterStorageCapacity
bldg:boilerWaterStorageCapacity rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Boiler ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Water storage capacity. Usually measured in cubic metre (m3)."@en ;
                                rdfs:label "water storage capacity"@en .


###  http://saref.linkeddata.es/def/bldg#burnerEnergySource
bldg:burnerEnergySource rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Burner ;
                        rdfs:range xsd:string ;
                        rdfs:comment "Enumeration defining the energy source or fuel cumbusted to generate heat."@en ;
                        rdfs:label "energy source"@en .


###  http://saref.linkeddata.es/def/bldg#chillerNominalCapacity
bldg:chillerNominalCapacity rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Chiller ;
                            rdfs:range xsd:float ;
                            rdfs:comment " Nominal cooling capacity of chiller at standardized conditions as defined by the agency having jurisdiction. Usually measured in Watts (W, J/s)."@en ;
                            rdfs:label "nominal capacity"@en .


###  http://saref.linkeddata.es/def/bldg#chillerNominalCondensingTemperature
bldg:chillerNominalCondensingTemperature rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:Chiller ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " Chiller condensing temperature. Usually measured in degrees Kelvin (K)."@en ;
                                         rdfs:label "nominal condensing temperature"@en .


###  http://saref.linkeddata.es/def/bldg#chillerNominalEfficiency
bldg:chillerNominalEfficiency rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Chiller ;
                              rdfs:range xsd:float ;
                              rdfs:comment " Nominal chiller efficiency under nominal conditions. "@en ;
                              rdfs:label "nominal efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#chillerNominalEvaporatingTemmperature
bldg:chillerNominalEvaporatingTemmperature rdf:type owl:DatatypeProperty ;
                                           rdfs:domain bldg:Chiller ;
                                           rdfs:range xsd:float ;
                                           rdfs:comment " Chiller evaporating temperature.Usually measured in degrees Kelvin (K)."@en ;
                                           rdfs:label "nominal evaporating temmperature"@en .


###  http://saref.linkeddata.es/def/bldg#chillerNominalHeatRejectionRate
bldg:chillerNominalHeatRejectionRate rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Chiller ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Sum of the refrigeration effect and the heat equivalent of the power input to the compressor. Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "nominal heat rejection rate"@en .


###  http://saref.linkeddata.es/def/bldg#chillerNominalPowerConsumption
bldg:chillerNominalPowerConsumption rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Chiller ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Nominal total power consumption. Usually measured in Watts (W, J/s)."@en ;
                                    rdfs:label "nominal power consumption"@en .


###  http://saref.linkeddata.es/def/bldg#coilAirFlowRateRangeMax
bldg:coilAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Coil ;
                             rdfs:range xsd:float ;
                             rdfs:comment "Possible range of airflow that can be delivered. For cases where there is no airflow across the coil (e.g. electric coil in a floor slab), then the value is zero. Usually measured in m3/s."@en ;
                             rdfs:label "air flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#coilAirFlowRateRangeMin
bldg:coilAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Coil ;
                             rdfs:range xsd:float ;
                             rdfs:comment "Possible range of airflow that can be delivered. For cases where there is no airflow across the coil (e.g. electric coil in a floor slab), then the value is zero. Usually measured in m3/s."@en ;
                             rdfs:label "air flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#coilNominalLatentCapacity
bldg:coilNominalLatentCapacity rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Coil ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Nominal latent capacity. Usually measured in Watts (W, J/s)."@en ;
                               rdfs:label "nominal latent capacity"@en .


###  http://saref.linkeddata.es/def/bldg#coilNominalSensibleCapacity
bldg:coilNominalSensibleCapacity rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Coil ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Nominal sensible capacity. Usually measured in Watts (W, J/s)."@en ;
                                 rdfs:label "nominal sensible capacity"@en .


###  http://saref.linkeddata.es/def/bldg#coilNominalUa
bldg:coilNominalUa rdf:type owl:DatatypeProperty ;
                   rdfs:domain bldg:Coil ;
                   rdfs:range xsd:float ;
                   rdfs:comment " Nominal UA value."@en ;
                   rdfs:label "nominal ua"@en .


###  http://saref.linkeddata.es/def/bldg#coilOperationalTemperatureRangeMax
bldg:coilOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Coil ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment "Allowable operational air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                        rdfs:label "operational temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#coilOperationalTemperatureRangeMin
bldg:coilOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Coil ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment "Allowable operational air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                        rdfs:label "operational temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#coilPlacementType
bldg:coilPlacementType rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Coil ;
                       rdfs:range xsd:string ;
                       rdfs:comment " Indicates the placement of the coil. FLOOR indicates an under floor heater (if coil type is WATERHEATINGCOIL or ELECTRICHEATINGCOIL), CEILING indicates a cooling ceiling (if coil type is WATERCOOLINGCOIL), UNIT indicates that the coil is part of a cooling or heating unit, like cooled beam, etc."@en ;
                       rdfs:label "placement type"@en .


###  http://saref.linkeddata.es/def/bldg#compressorCompressorSpeed
bldg:compressorCompressorSpeed rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Compressor ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Compressor speed. Usually measured in cycles/s."@en ;
                               rdfs:label "compressor speed"@en .


###  http://saref.linkeddata.es/def/bldg#compressorHasHotGasBypass
bldg:compressorHasHotGasBypass rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Compressor ;
                               rdfs:range xsd:boolean ;
                               rdfs:comment " Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No."@en ;
                               rdfs:label "has hot gas bypass"@en .


###  http://saref.linkeddata.es/def/bldg#compressorIdealCapacity
bldg:compressorIdealCapacity rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Compressor ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Compressor capacity under ideal conditions. Usually measured in Watts (W, J/s)."@en ;
                             rdfs:label "ideal capacity"@en .


###  http://saref.linkeddata.es/def/bldg#compressorIdealShaftPower
bldg:compressorIdealShaftPower rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Compressor ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Compressor shaft power under ideal conditions. Usually measured in Watts (W, J/s)."@en ;
                               rdfs:label "ideal shaft power"@en .


###  http://saref.linkeddata.es/def/bldg#compressorImpellerDiameter
bldg:compressorImpellerDiameter rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Compressor ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Diameter of compressor impeller - used to scale performance of geometrically similar compressors. Usually measured in millimeters (mm)."@en ;
                                rdfs:label "impeller diameter"@en .


###  http://saref.linkeddata.es/def/bldg#compressorMaximumPartLoadRatio
bldg:compressorMaximumPartLoadRatio rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Compressor ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Maximum part load ratio as a fraction of nominal capacity."@en ;
                                    rdfs:label "maximum part load ratio"@en .


###  http://saref.linkeddata.es/def/bldg#compressorMinimunPartLoadRatio
bldg:compressorMinimunPartLoadRatio rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Compressor ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Minimum part load ratio as a fraction of nominal capacity."@en ;
                                    rdfs:label "minimun part load ratio"@en .


###  http://saref.linkeddata.es/def/bldg#compressorNominalCapacity
bldg:compressorNominalCapacity rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Compressor ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Compressor nameplate capacity. Usually measured in Watts (W, J/s)."@en ;
                               rdfs:label "nominal capacity"@en .


###  http://saref.linkeddata.es/def/bldg#compressorPowerSource
bldg:compressorPowerSource rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Compressor ;
                           rdfs:range xsd:string ;
                           rdfs:comment " Type of power driving the compressor."@en ;
                           rdfs:label "power source"@en .


###  http://saref.linkeddata.es/def/bldg#compressorRefrigerantClass
bldg:compressorRefrigerantClass rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Compressor ;
                                rdfs:range xsd:string ;
                                rdfs:comment "Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
                                rdfs:label "refrigerant class"@en .


###  http://saref.linkeddata.es/def/bldg#condenserExternalSurfaceArea
bldg:condenserExternalSurfaceArea rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Condenser ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " External surface area (both primary and secondary area). Usually measured in square metre (m2)."@en ;
                                  rdfs:label "external surface area"@en .


###  http://saref.linkeddata.es/def/bldg#condenserInternalRefrigerantVolume
bldg:condenserInternalRefrigerantVolume rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Condenser ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment " Internal volume of condenser (refrigerant side). Usually measured in cubic metre (m3)."@en ;
                                        rdfs:label "internal refrigerant volume"@en .


###  http://saref.linkeddata.es/def/bldg#condenserInternalSurfaceArea
bldg:condenserInternalSurfaceArea rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Condenser ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Internal surface area. Usually measured in square metre (m2)."@en ;
                                  rdfs:label "internal surface area"@en .


###  http://saref.linkeddata.es/def/bldg#condenserInternalWaterVolume
bldg:condenserInternalWaterVolume rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Condenser ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Internal volume of condenser (water side). Usually measured in cubic metre (m3)."@en ;
                                  rdfs:label "internal water volume"@en .


###  http://saref.linkeddata.es/def/bldg#condenserNominalHeatTransferArea
bldg:condenserNominalHeatTransferArea rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:Condenser ;
                                      rdfs:range xsd:float ;
                                      rdfs:comment " Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2)."@en ;
                                      rdfs:label "nominal heat transfer area"@en .


###  http://saref.linkeddata.es/def/bldg#condenserNominalHeatTransferCoefficient
bldg:condenserNominalHeatTransferCoefficient rdf:type owl:DatatypeProperty ;
                                             rdfs:domain bldg:Condenser ;
                                             rdfs:range xsd:float ;
                                             rdfs:comment " Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin."@en ;
                                             rdfs:label "nominal heat transfer coefficient"@en .


###  http://saref.linkeddata.es/def/bldg#condenserRefrigerantClass
bldg:condenserRefrigerantClass rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Condenser ;
                               rdfs:range xsd:string ;
                               rdfs:comment "Refrigerant class used by the condenser. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
                               rdfs:label "refrigerant class"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamCoilLength
bldg:cooledBeamCoilLength rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:CooledBeam ;
                          rdfs:range xsd:float ;
                          rdfs:comment " Length of coil. Usually measured in millimeters (mm)."@en ;
                          rdfs:label "coil length"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamCoilWidth
bldg:cooledBeamCoilWidth rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:CooledBeam ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Width of coil. Usually measured in millimeters (mm"@en ;
                         rdfs:label "coil width"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamFinishColor
bldg:cooledBeamFinishColor rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:CooledBeam ;
                           rdfs:range xsd:string ;
                           rdfs:comment " Finish color for cooled beam."@en ;
                           rdfs:label "finish color"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamIntegratedLightingType
bldg:cooledBeamIntegratedLightingType rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:CooledBeam ;
                                      rdfs:range xsd:string ;
                                      rdfs:comment "Integrated lighting in cooled beam."@en ;
                                      rdfs:label "integrated lighting type"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamIsFreeHanging
bldg:cooledBeamIsFreeHanging rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:CooledBeam ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " Is it free hanging type (not mounted in a false ceiling)?"@en ;
                             rdfs:label "is free hanging"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalCoolingCapacity
bldg:cooledBeamNominalCoolingCapacity rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:CooledBeam ;
                                      rdfs:range xsd:float ;
                                      rdfs:comment " Nominal cooling capacity. Usually measured in Watts (W, J/s)."@en ;
                                      rdfs:label "nominal cooling capacity"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalHeatingCapacity
bldg:cooledBeamNominalHeatingCapacity rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:CooledBeam ;
                                      rdfs:range xsd:float ;
                                      rdfs:comment " Nominal heating capacity. Usually measured in Watts (W, J/s)."@en ;
                                      rdfs:label "nominal heating capacity"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalReturnWaterTemperatureCooling
bldg:cooledBeamNominalReturnWaterTemperatureCooling rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:CooledBeam ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment " Nominal return water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                    rdfs:label "nominal return water temperature cooling"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalReturnWaterTemperatureHeating
bldg:cooledBeamNominalReturnWaterTemperatureHeating rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:CooledBeam ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment " Nominal return water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                    rdfs:label "nominal return water temperature heating"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalSorroundingHumidityCooling
bldg:cooledBeamNominalSorroundingHumidityCooling rdf:type owl:DatatypeProperty ;
                                                 rdfs:domain bldg:CooledBeam ;
                                                 rdfs:range xsd:float ;
                                                 rdfs:comment " Nominal surrounding humidity (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                 rdfs:label "nominal sorrounding humidity cooling"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalSorroundingTemperatureCooling
bldg:cooledBeamNominalSorroundingTemperatureCooling rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:CooledBeam ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment " Nominal surrounding temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                    rdfs:label "nominal sorrounding temperature cooling"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalSorroundingTemperatureHeating
bldg:cooledBeamNominalSorroundingTemperatureHeating rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:CooledBeam ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment " Nominal surrounding temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                    rdfs:label "nominal sorrounding temperature heating"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalSupplyWaterTemperatureCooling
bldg:cooledBeamNominalSupplyWaterTemperatureCooling rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:CooledBeam ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment " Nominal supply water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                    rdfs:label "nominal supply water temperature cooling"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalSupplyWaterTemperatureHeating
bldg:cooledBeamNominalSupplyWaterTemperatureHeating rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:CooledBeam ;
                                                    rdfs:range xsd:float ;
                                                    rdfs:comment " Nominal supply water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
                                                    rdfs:label "nominal supply water temperature heating"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalWaterFlowCooling
bldg:cooledBeamNominalWaterFlowCooling rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:CooledBeam ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Nominal water flow (refers to nominal cooling capacity). Usually measured in m3/s."@en ;
                                       rdfs:label "nominal water flow cooling"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamNominalWaterFlowHeating
bldg:cooledBeamNominalWaterFlowHeating rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:CooledBeam ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Nominal water flow (refers to nominal heating capacity). Usually measured in m3/s."@en ;
                                       rdfs:label "nominal water flow heating"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamPipeConnectionEnum
bldg:cooledBeamPipeConnectionEnum rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:CooledBeam ;
                                  rdfs:range xsd:string ;
                                  rdfs:comment "The manner in which the pipe connection is made to the cooled beam."@en ;
                                  rdfs:label "pipe connection enum"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamWaterFlowControlSystemType
bldg:cooledBeamWaterFlowControlSystemType rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:CooledBeam ;
                                          rdfs:range xsd:string ;
                                          rdfs:comment " Factory fitted waterflow control system."@en ;
                                          rdfs:label "water flow control system type"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamWaterPressureRangeMax
bldg:cooledBeamWaterPressureRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:CooledBeam ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
                                     rdfs:label "water pressure range max"@en .


###  http://saref.linkeddata.es/def/bldg#cooledBeamWaterPressureRangeMin
bldg:cooledBeamWaterPressureRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:CooledBeam ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
                                     rdfs:label "water pressure range min"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerAmbientDesignDryBulbTemperature
bldg:coolingTowerAmbientDesignDryBulbTemperature rdf:type owl:DatatypeProperty ;
                                                 rdfs:domain bldg:CoolingTower ;
                                                 rdfs:range xsd:float ;
                                                 rdfs:comment " Ambient design dry bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K)."@en ;
                                                 rdfs:label "ambient design dry bulb temperature"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerAmbientDesignWetBulbTemperature
bldg:coolingTowerAmbientDesignWetBulbTemperature rdf:type owl:DatatypeProperty ;
                                                 rdfs:domain bldg:CoolingTower ;
                                                 rdfs:range xsd:float ;
                                                 rdfs:comment " Ambient design wet bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K)."@en ;
                                                 rdfs:label "ambient design wet bulb temperature"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerBasinReserveVolume
bldg:coolingTowerBasinReserveVolume rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:CoolingTower ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Volume between operating and overflow levels in cooling tower basin. Usually measured in cubic metre (m3)."@en ;
                                    rdfs:label "basin reserve volume"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerCapacityControl
bldg:coolingTowerCapacityControl rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:CoolingTower ;
                                 rdfs:range xsd:string ;
                                 rdfs:comment "FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty."@en ;
                                 rdfs:label "capacity control"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerCircuitType
bldg:coolingTowerCircuitType rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:CoolingTower ;
                             rdfs:range xsd:string ;
                             rdfs:comment "OpenCircuit: Exposes water directly to the cooling atmosphere. CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger. Wet: The air stream or the heat exchange surface is evaporatively cooled. Dry: No evaporation into the air stream. DryWet: A combination of a dry tower and a wet tower."@en ;
                             rdfs:label "circuit type"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerControlStrategy
bldg:coolingTowerControlStrategy rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:CoolingTower ;
                                 rdfs:range xsd:string ;
                                 rdfs:comment "FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature. WetBulbTempReset: The set-point is reset based on the wet-bulb temperature."@en ;
                                 rdfs:label "control strategy"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerFlowArrangement
bldg:coolingTowerFlowArrangement rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:CoolingTower ;
                                 rdfs:range xsd:string ;
                                 rdfs:comment " CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: air and water flow enter in same directions."@en ;
                                 rdfs:label "flow arrangement"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerLiftElevationDifference
bldg:coolingTowerLiftElevationDifference rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:CoolingTower ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " Elevation difference between cooling tower sump and the top of the tower. Usually measured in millimeters (mm)."@en ;
                                         rdfs:label "lift elevation difference"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerNominalCapcity
bldg:coolingTowerNominalCapcity rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:CoolingTower ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Nominal cooling tower capacity in terms of heat transfer rate of the cooling tower between air stream and water stream at nominal conditions. Usually measured in Watts (W, J/s)."@en ;
                                rdfs:label "nominal capcity"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerNumberOfCells
bldg:coolingTowerNumberOfCells rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:CoolingTower ;
                               rdfs:range xsd:integer ;
                               rdfs:comment " Number of cells in one cooling tower unit."@en ;
                               rdfs:label "number of cells"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerOperationTemperatureRange
bldg:coolingTowerOperationTemperatureRange rdf:type owl:DatatypeProperty ;
                                           rdfs:domain bldg:CoolingTower ;
                                           rdfs:range xsd:float ;
                                           rdfs:comment " Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                           rdfs:label "operation temperature range"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerSprayType
bldg:coolingTowerSprayType rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:CoolingTower ;
                           rdfs:range xsd:string ;
                           rdfs:comment " SprayFilled: Water is sprayed into airflow. SplashTypeFill: water cascades over successive rows of splash bars. FilmTypeFill: water flows in a thin layer over closely spaced sheets."@en ;
                           rdfs:label "spray type"@en .


###  http://saref.linkeddata.es/def/bldg#coolingTowerWaterRequirement
bldg:coolingTowerWaterRequirement rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:CoolingTower ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Make-up water requirements. Usually measured in m3/s."@en ;
                                  rdfs:label "water requirement"@en .


###  http://saref.linkeddata.es/def/bldg#damperBladeAction
bldg:damperBladeAction rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Damper ;
                       rdfs:range xsd:string ;
                       rdfs:comment "Blade action."@en ;
                       rdfs:label "blade action"@en .


###  http://saref.linkeddata.es/def/bldg#damperBladeEdge
bldg:damperBladeEdge rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Damper ;
                     rdfs:range xsd:string ;
                     rdfs:comment "Blade edge."@en ;
                     rdfs:label "blade edge"@en .


###  http://saref.linkeddata.es/def/bldg#damperBladeShape
bldg:damperBladeShape rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Damper ;
                      rdfs:range xsd:string ;
                      rdfs:comment "Blade shape. Flat means triple V-groove."@en ;
                      rdfs:label "blade shape"@en .


###  http://saref.linkeddata.es/def/bldg#damperBladeThickness
bldg:damperBladeThickness rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Damper ;
                          rdfs:range xsd:float ;
                          rdfs:comment " The thickness of the damper blade. Usually measured in millimeters (mm)."@en ;
                          rdfs:label "blade thickness"@en .


###  http://saref.linkeddata.es/def/bldg#damperCloseOffRating
bldg:damperCloseOffRating rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Damper ;
                          rdfs:range xsd:float ;
                          rdfs:comment " Close off rating. Usually measured in Pascals (Pa, N/m2)."@en ;
                          rdfs:label "close off rating"@en .


###  http://saref.linkeddata.es/def/bldg#damperFaceArea
bldg:damperFaceArea rdf:type owl:DatatypeProperty ;
                    rdfs:domain bldg:Damper ;
                    rdfs:range xsd:float ;
                    rdfs:comment " Face area open to the airstream. Usually measured in square metre (m2)."@en ;
                    rdfs:label "face area"@en .


###  http://saref.linkeddata.es/def/bldg#damperFrameDepth
bldg:damperFrameDepth rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Damper ;
                      rdfs:range xsd:float ;
                      rdfs:comment " The length (or depth) of the damper frame. Usually measured in millimeters (mm)."@en ;
                      rdfs:label "frame depth"@en .


###  http://saref.linkeddata.es/def/bldg#damperFrameThickness
bldg:damperFrameThickness rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Damper ;
                          rdfs:range xsd:float ;
                          rdfs:comment " The thickness of the damper frame material. Usually measured in millimeters (mm)."@en ;
                          rdfs:label "frame thickness"@en .


###  http://saref.linkeddata.es/def/bldg#damperFrameType
bldg:damperFrameType rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Damper ;
                     rdfs:range xsd:string ;
                     rdfs:comment " The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.)."@en ;
                     rdfs:label "frame type"@en .


###  http://saref.linkeddata.es/def/bldg#damperLeakageFullyClosed
bldg:damperLeakageFullyClosed rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Damper ;
                              rdfs:range xsd:float ;
                              rdfs:comment " Leakage when fully closed. Usually measured in m3/s."@en ;
                              rdfs:label "leakage fully closed"@en .


###  http://saref.linkeddata.es/def/bldg#damperMaximumAirFlowRate
bldg:damperMaximumAirFlowRate rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Damper ;
                              rdfs:range xsd:float ;
                              rdfs:comment " Maximum allowable air flow rate. Usually measured in m3/s."@en ;
                              rdfs:label "maximum air flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#damperMaximumWorkingPressure
bldg:damperMaximumWorkingPressure rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Damper ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Maximum working pressure. Usually measured in Pascals (Pa, N/m2)."@en ;
                                  rdfs:label "maximum working pressure"@en .


###  http://saref.linkeddata.es/def/bldg#damperNominalAirFlowRate
bldg:damperNominalAirFlowRate rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Damper ;
                              rdfs:range xsd:float ;
                              rdfs:comment " Nominal air flow rate. Usually measured in m3/s."@en ;
                              rdfs:label "nominal air flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#damperNumberOfBlades
bldg:damperNumberOfBlades rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Damper ;
                          rdfs:range xsd:integer ;
                          rdfs:comment " Number of blades."@en ;
                          rdfs:label "number of blades"@en .


###  http://saref.linkeddata.es/def/bldg#damperOpenPressureDrop
bldg:damperOpenPressureDrop rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Damper ;
                            rdfs:range xsd:float ;
                            rdfs:comment " Total pressure drop across damper. Usually measured in Pascals (Pa, N/m2)."@en ;
                            rdfs:label "open pressure drop"@en .


###  http://saref.linkeddata.es/def/bldg#damperOperation
bldg:damperOperation rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Damper ;
                     rdfs:range xsd:string ;
                     rdfs:comment "The operational mechanism for the damper operation."@en ;
                     rdfs:label "operation"@en .


###  http://saref.linkeddata.es/def/bldg#damperOrientation
bldg:damperOrientation rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Damper ;
                       rdfs:range xsd:string ;
                       rdfs:comment "The intended orientation for the damper as specified by the manufacturer."@en ;
                       rdfs:label "orientation"@en .


###  http://saref.linkeddata.es/def/bldg#damperTemperatureRangeMax
bldg:damperTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Damper ;
                               rdfs:range xsd:float ;
                               rdfs:comment "Temperature range. Usually measured in degrees Kelvin (K)."@en ;
                               rdfs:label "temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#damperTemperatureRangeMin
bldg:damperTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Damper ;
                               rdfs:range xsd:float ;
                               rdfs:comment "Temperature range. Usually measured in degrees Kelvin (K)."@en ;
                               rdfs:label "temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#damperTemperatureRating
bldg:damperTemperatureRating rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Damper ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Temperature rating. Usually measured in degrees Kelvin (K)."@en ;
                             rdfs:label "temperature rating"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerAirFlowRateRangeMax
bldg:ductSilencerAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:DuctSilencer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Possible range of airflow that can be delivered. Usually measured in m3/s."@en ;
                                     rdfs:label "air flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerAirFlowRateRangeMin
bldg:ductSilencerAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:DuctSilencer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Possible range of airflow that can be delivered. Usually measured in m3/s."@en ;
                                     rdfs:label "air flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerHasExteriorInsulation
bldg:ductSilencerHasExteriorInsulation rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:DuctSilencer ;
                                       rdfs:range xsd:boolean ;
                                       rdfs:comment " TRUE if the silencer has exterior insulation. FALSE if it does not."@en ;
                                       rdfs:label "has exterior insulation"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerHydraulicDiameter
bldg:ductSilencerHydraulicDiameter rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:DuctSilencer ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Hydraulic diameter. Usually measured in millimeters (mm)."@en ;
                                   rdfs:label "hydraulic diameter"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerLength
bldg:ductSilencerLength rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:DuctSilencer ;
                        rdfs:range xsd:float ;
                        rdfs:comment " The finished length of the silencer. Usually measured in millimeters (mm)."@en ;
                        rdfs:label "length"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerTemperatureRangeMax
bldg:ductSilencerTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:DuctSilencer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable minimum and maximum temperature. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerTemperatureRangeMin
bldg:ductSilencerTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:DuctSilencer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable minimum and maximum temperature. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerWeight
bldg:ductSilencerWeight rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:DuctSilencer ;
                        rdfs:range xsd:float ;
                        rdfs:comment " The weight of the silencer. Usually measured in kilograms (kg) or grams (g)."@en ;
                        rdfs:label "weight"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerWorkingPressureRangeMax
bldg:ductSilencerWorkingPressureRangeMax rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:DuctSilencer ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment "Allowable minimum and maximum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
                                         rdfs:label "working pressure range max"@en .


###  http://saref.linkeddata.es/def/bldg#ductSilencerWorkingPressureRangeMin
bldg:ductSilencerWorkingPressureRangeMin rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:DuctSilencer ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment "Allowable minimum and maximum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
                                         rdfs:label "working pressure range min"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalFrequency
bldg:electricFlowStorageDeviceNominalFrequency rdf:type owl:DatatypeProperty ;
                                               rdfs:domain bldg:ElectricFlowStorageDevice ;
                                               rdfs:range xsd:float ;
                                               rdfs:comment " The nominal frequency of the supply. Usually measured in cycles/s or Hertz (Hz)."@en ;
                                               rdfs:label "nominal frequency"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltage
bldg:electricFlowStorageDeviceNominalSupplyVoltage rdf:type owl:DatatypeProperty ;
                                                   rdfs:domain bldg:ElectricFlowStorageDevice ;
                                                   rdfs:range xsd:float ;
                                                   rdfs:comment " The nominal voltage of the supply. Usually measured in Volts (V, W/A)."@en ;
                                                   rdfs:label "nominal supply voltage"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltageOffsetMax
bldg:electricFlowStorageDeviceNominalSupplyVoltageOffsetMax rdf:type owl:DatatypeProperty ;
                                                            rdfs:domain bldg:ElectricFlowStorageDevice ;
                                                            rdfs:range xsd:float ;
                                                            rdfs:comment " The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
                                                            rdfs:label "nominal supply voltage offset max"@en .


###  http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltageOffsetMin
bldg:electricFlowStorageDeviceNominalSupplyVoltageOffsetMin rdf:type owl:DatatypeProperty ;
                                                            rdfs:domain bldg:ElectricFlowStorageDevice ;
                                                            rdfs:range xsd:float ;
                                                            rdfs:comment " The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
                                                            rdfs:label "nominal supply voltage offset min"@en .


###  http://saref.linkeddata.es/def/bldg#electricGeneratorElectricGeneratorEfficiency
bldg:electricGeneratorElectricGeneratorEfficiency rdf:type owl:DatatypeProperty ;
                                                  rdfs:domain bldg:ElectricGenerator ;
                                                  rdfs:range xsd:float ;
                                                  rdfs:comment " the ratio of output capacity to intake capacity."@en ;
                                                  rdfs:label "electric generator efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#electricGeneratorMaximumPowerOutput
bldg:electricGeneratorMaximumPowerOutput rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:ElectricGenerator ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
                                         rdfs:label "maximum power output"@en .


###  http://saref.linkeddata.es/def/bldg#electricGeneratorStartCurrentFactor
bldg:electricGeneratorStartCurrentFactor rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:ElectricGenerator ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
                                         rdfs:label "start current factor"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorElectricMotorEfficiency
bldg:electricMotorElectricMotorEfficiency rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:ElectricMotor ;
                                          rdfs:range xsd:float ;
                                          rdfs:comment " The ratio of output capacity to intake capacity."@en ;
                                          rdfs:label "electric motor efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorFrameSize
bldg:electricMotorFrameSize rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:ElectricMotor ;
                            rdfs:range xsd:string ;
                            rdfs:comment " Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard."@en ;
                            rdfs:label "frame size"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorHasPartWinding
bldg:electricMotorHasPartWinding rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:ElectricMotor ;
                                 rdfs:range xsd:boolean ;
                                 rdfs:comment " Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) ."@en ;
                                 rdfs:label "has part winding"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorIsGuarded
bldg:electricMotorIsGuarded rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:ElectricMotor ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE)."@en ;
                            rdfs:label "is guarded"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorLockedRotorCurrent
bldg:electricMotorLockedRotorCurrent rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Input current when a motor armature is energized but not rotating. Usually measured in Ampere (A)."@en ;
                                     rdfs:label "locked rotor current"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorMaximumPowerOutput
bldg:electricMotorMaximumPowerOutput rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "maximum power output"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorMotorEnclosureType
bldg:electricMotorMotorEnclosureType rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment " A list of the available types of motor enclosure from which that required may be selected."@en ;
                                     rdfs:label "motor enclosure type"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorStartCurrentFactor
bldg:electricMotorStartCurrentFactor rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ElectricMotor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
                                     rdfs:label "start current factor"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorStartingTime
bldg:electricMotorStartingTime rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:ElectricMotor ;
                               rdfs:range xsd:float ;
                               rdfs:comment " The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals."@en ;
                               rdfs:label "starting time"@en .


###  http://saref.linkeddata.es/def/bldg#electricMotorTeTime
bldg:electricMotorTeTime rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:ElectricMotor ;
                         rdfs:range xsd:float ;
                         rdfs:comment " The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device."@en ;
                         rdfs:label "te time"@en .


###  http://saref.linkeddata.es/def/bldg#engineEnergySource
bldg:engineEnergySource rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Engine ;
                        rdfs:range xsd:string ;
                        rdfs:comment "The source of energy."@en ;
                        rdfs:label "energy source"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerFlowArrangement
bldg:evaporativeCoolerFlowArrangement rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:EvaporativeCooler ;
                                      rdfs:range xsd:string ;
                                      rdfs:comment "CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: Air and water flow enter in same directions."@en ;
                                      rdfs:label "flow arrangement"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerHeatExchangeArea
bldg:evaporativeCoolerHeatExchangeArea rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:EvaporativeCooler ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Heat exchange area. Usually measured in square metre (m2)."@en ;
                                       rdfs:label "heat exchange area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerOperationalTemperatureRangeMax
bldg:evaporativeCoolerOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                                     rdfs:domain bldg:EvaporativeCooler ;
                                                     rdfs:range xsd:float ;
                                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                                     rdfs:label "operational temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerOperationalTemperatureRangeMin
bldg:evaporativeCoolerOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                                     rdfs:domain bldg:EvaporativeCooler ;
                                                     rdfs:range xsd:float ;
                                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                                     rdfs:label "operational temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#evaporativeCoolerWaterRequirement
bldg:evaporativeCoolerWaterRequirement rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:EvaporativeCooler ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Make-up water requirement. Usually measured in m3/s."@en ;
                                       rdfs:label "water requirement"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorEvaporationCoolant
bldg:evaporatorEvaporationCoolant rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Evaporator ;
                                  rdfs:range xsd:string ;
                                  rdfs:comment "The fluid used for the coolant in the evaporator."@en ;
                                  rdfs:label "evaporation coolant"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorEvaporationMediumType
bldg:evaporatorEvaporationMediumType rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Evaporator ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment "ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant."@en ;
                                     rdfs:label "evaporation medium type"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorExternalSurfaceArea
bldg:evaporatorExternalSurfaceArea rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Evaporator ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " External surface area (both primary and secondary area). Usually measured in square metre (m2)."@en ;
                                   rdfs:label "external surface area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorInternalRefrigerantVolume
bldg:evaporatorInternalRefrigerantVolume rdf:type owl:DatatypeProperty ;
                                         rdfs:domain bldg:Evaporator ;
                                         rdfs:range xsd:float ;
                                         rdfs:comment " Internal volume of evaporator (refrigerant side). Usually measured in cubic metre (m3)."@en ;
                                         rdfs:label "internal refrigerant volume"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorInternalSurfaceArea
bldg:evaporatorInternalSurfaceArea rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Evaporator ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Internal surface area. Usually measured in square metre (m2)."@en ;
                                   rdfs:label "internal surface area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorInternalWaterVolume
bldg:evaporatorInternalWaterVolume rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Evaporator ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Internal volume of evaporator (water side). Usually measured in cubic metre (m3)."@en ;
                                   rdfs:label "internal water volume"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorNominalHeatTransferArea
bldg:evaporatorNominalHeatTransferArea rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Evaporator ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2)."@en ;
                                       rdfs:label "nominal heat transfer area"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorNominalHeatTransferCoefficient
bldg:evaporatorNominalHeatTransferCoefficient rdf:type owl:DatatypeProperty ;
                                              rdfs:domain bldg:Evaporator ;
                                              rdfs:range xsd:float ;
                                              rdfs:comment " Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin."@en ;
                                              rdfs:label "nominal heat transfer coefficient"@en .


###  http://saref.linkeddata.es/def/bldg#evaporatorRefrigerantClass
bldg:evaporatorRefrigerantClass rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Evaporator ;
                                rdfs:range xsd:string ;
                                rdfs:comment " Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
                                rdfs:label "refrigerant class"@en .


###  http://saref.linkeddata.es/def/bldg#fanCapacityControlType
bldg:fanCapacityControlType rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Fan ;
                            rdfs:range xsd:string ;
                            rdfs:comment "InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper."@en ;
                            rdfs:label "capacity control type"@en .


###  http://saref.linkeddata.es/def/bldg#fanMotorDriveType
bldg:fanMotorDriveType rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Fan ;
                       rdfs:range xsd:string ;
                       rdfs:comment "Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type. "@en ;
                       rdfs:label "motor drive type"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalAirFlowRate
bldg:fanNominalAirFlowRate rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Fan ;
                           rdfs:range xsd:float ;
                           rdfs:comment " Nominal air flow rate. Usually measured in m3/s."@en ;
                           rdfs:label "nominal air flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalPowerRate
bldg:fanNominalPowerRate rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Fan ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Nominal fan power rate.Usually measured in Watts (W, J/s)."@en ;
                         rdfs:label "nominal power rate"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalRotationSpeed
bldg:fanNominalRotationSpeed rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Fan ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Nominal fan wheel speed. Usually measured in cycles/s."@en ;
                             rdfs:label "nominal rotation speed"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalStaticPressure
bldg:fanNominalStaticPressure rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Fan ;
                              rdfs:range xsd:float ;
                              rdfs:comment " The static pressure within the air stream that the fan must overcome to insure designed circulation of air. Usually measured in Pascals (Pa, N/m2)."@en ;
                              rdfs:label "nominal static pressure"@en .


###  http://saref.linkeddata.es/def/bldg#fanNominalTotalPressure
bldg:fanNominalTotalPressure rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Fan ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Nominal total pressure rise across the fan. Usually measured in Pascals (Pa, N/m2)."@en ;
                             rdfs:label "nominal total pressure"@en .


###  http://saref.linkeddata.es/def/bldg#fanOperationTemperatureRangeMax
bldg:fanOperationTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Fan ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "operation temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#fanOperationTemperatureRangeMin
bldg:fanOperationTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Fan ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                     rdfs:label "operation temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#fanOperationalRiterial
bldg:fanOperationalRiterial rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Fan ;
                            rdfs:range xsd:float ;
                            rdfs:comment " Time of operation at maximum operational ambient air temperature. Measured in seconds (s) or days (d) or other units of time."@en ;
                            rdfs:label "operational riterial"@en .


###  http://saref.linkeddata.es/def/bldg#filterFinalResistance
bldg:filterFinalResistance rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Filter ;
                           rdfs:range xsd:float ;
                           rdfs:comment " Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
                           rdfs:label "final resistance"@en .


###  http://saref.linkeddata.es/def/bldg#filterFlowRateRangeMax
bldg:filterFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Filter ;
                            rdfs:range xsd:float ;
                            rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
                            rdfs:label "flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#filterFlowRateRangeMin
bldg:filterFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Filter ;
                            rdfs:range xsd:float ;
                            rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
                            rdfs:label "flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#filterInitialResistance
bldg:filterInitialResistance rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Filter ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
                             rdfs:label "initial resistance"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalFilterFaceVelocity
bldg:filterNominalFilterFaceVelocity rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Filter ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Filter face velocity. Usually measured in m/s."@en ;
                                     rdfs:label "nominal filter face velocity"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalFlowRate
bldg:filterNominalFlowRate rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Filter ;
                           rdfs:range xsd:float ;
                           rdfs:comment " Nominal fluid flow rate through the filter. Usually measured in m3/s."@en ;
                           rdfs:label "nominal flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalMediaSurfaceVelocity
bldg:filterNominalMediaSurfaceVelocity rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Filter ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " Average fluid velocity at the media surface. Usually measured in m/s."@en ;
                                       rdfs:label "nominal media surface velocity"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalParticleGeometricMeanDiameter
bldg:filterNominalParticleGeometricMeanDiameter rdf:type owl:DatatypeProperty ;
                                                rdfs:domain bldg:Filter ;
                                                rdfs:range xsd:float ;
                                                rdfs:comment " Particle geometric mean diameter associated with nominal efficiency. Usually measured in millimeters (mm)."@en ;
                                                rdfs:label "nominal particle geometric mean diameter"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalParticleGeometricStandardDeviation
bldg:filterNominalParticleGeometricStandardDeviation rdf:type owl:DatatypeProperty ;
                                                     rdfs:domain bldg:Filter ;
                                                     rdfs:range xsd:float ;
                                                     rdfs:comment " Particle geometric standard deviation associated with nominal efficiency. "@en ;
                                                     rdfs:label "nominal particle geometric standard deviation"@en .


###  http://saref.linkeddata.es/def/bldg#filterNominalPressureDrop
bldg:filterNominalPressureDrop rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Filter ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Total pressure drop across the filter. Usually measured in Pascals (Pa, N/m2)."@en ;
                               rdfs:label "nominal pressure drop"@en .


###  http://saref.linkeddata.es/def/bldg#filterOperationTemperatureRangeMax
bldg:filterOperationTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Filter ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment "Allowable operation ambient fluid temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                        rdfs:label "operation temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#filterOperationTemperatureRangeMin
bldg:filterOperationTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Filter ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment "Allowable operation ambient fluid temperature range. Usually measured in degrees Kelvin (K)."@en ;
                                        rdfs:label "operation temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#filterWeight
bldg:filterWeight rdf:type owl:DatatypeProperty ;
                  rdfs:domain bldg:Filter ;
                  rdfs:range xsd:float ;
                  rdfs:comment " Weight of filter. Usually measured in kilograms (kg) or grams (g)."@en ;
                  rdfs:label "weight"@en .


###  http://saref.linkeddata.es/def/bldg#flowMeterReadOutType
bldg:flowMeterReadOutType rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:FlowMeter ;
                          rdfs:range xsd:string ;
                          rdfs:comment "Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer."@en ;
                          rdfs:label "read out type"@en .


###  http://saref.linkeddata.es/def/bldg#flowMeterRemoteReading
bldg:flowMeterRemoteReading rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:FlowMeter ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE)."@en ;
                            rdfs:label "remote reading"@en .


###  http://saref.linkeddata.es/def/bldg#heatExchangerArrangement
bldg:heatExchangerArrangement rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:HeatExchanger ;
                              rdfs:range xsd:string ;
                              rdfs:comment "Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above."@en ;
                              rdfs:label "arrangement"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierApplication
bldg:humidifierApplication rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Humidifier ;
                           rdfs:range xsd:string ;
                           rdfs:comment "Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system."@en ;
                           rdfs:label "application"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierInternalControl
bldg:humidifierInternalControl rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Humidifier ;
                               rdfs:range xsd:string ;
                               rdfs:comment "Internal modulation control."@en ;
                               rdfs:label "internal control"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierNominalAirFlowRate
bldg:humidifierNominalAirFlowRate rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Humidifier ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Nominal rate of air flow into which water vapor is added. Usually measured in m3/s."@en ;
                                  rdfs:label "nominal air flow rate"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierNominalMoistureGain
bldg:humidifierNominalMoistureGain rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Humidifier ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Nominal rate of water vapor added into the airstream. Usually measured in kg/s."@en ;
                                   rdfs:label "nominal moisture gain"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierWaterRequirement
bldg:humidifierWaterRequirement rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Humidifier ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Make-up water requirement. Usually measured in m3/s."@en ;
                                rdfs:label "water requirement"@en .


###  http://saref.linkeddata.es/def/bldg#humidifierWeight
bldg:humidifierWeight rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Humidifier ;
                      rdfs:range xsd:float ;
                      rdfs:comment " The weight of the humidifier. Usually measured in kilograms (kg) or grams (g)."@en ;
                      rdfs:label "weight"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorCoverLength
bldg:interceptorCoverLength rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:Interceptor ;
                            rdfs:range xsd:float ;
                            rdfs:comment " The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
                            rdfs:label "cover length"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorCoverWidth
bldg:interceptorCoverWidth rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Interceptor ;
                           rdfs:range xsd:float ;
                           rdfs:comment " The length measured along the x-axis in the local coordinate system of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
                           rdfs:label "cover width"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorInletConnectionSize
bldg:interceptorInletConnectionSize rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Interceptor ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Size of the inlet connection. Usually measured in millimeters (mm)."@en ;
                                    rdfs:label "inlet connection size"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorNominalBodyDepth
bldg:interceptorNominalBodyDepth rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Interceptor ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Nominal or quoted =length, measured along the z-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "nominal body depth"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorNominalBodyLength
bldg:interceptorNominalBodyLength rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Interceptor ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Nominal or quoted length, measured along the x-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
                                  rdfs:label "nominal body length"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorNominalBodyWidth
bldg:interceptorNominalBodyWidth rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Interceptor ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Nominal or quoted length, measured along the y-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "nominal body width"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorOutletConnectionSize
bldg:interceptorOutletConnectionSize rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Interceptor ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Size of the outlet connection. Usually measured in millimeters (mm)."@en ;
                                     rdfs:label "outlet connection size"@en .


###  http://saref.linkeddata.es/def/bldg#interceptorVentilatingPipeSize
bldg:interceptorVentilatingPipeSize rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:Interceptor ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Size of the ventilating pipe(s). Usually measured in millimeters (mm)."@en ;
                                    rdfs:label "ventilating pipe size"@en .


###  http://saref.linkeddata.es/def/bldg#lampColorAppearance
bldg:lampColorAppearance rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Lamp ;
                         rdfs:range xsd:string ;
                         rdfs:comment " In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance."@en ;
                         rdfs:label "color appearance"@en .


###  http://saref.linkeddata.es/def/bldg#lampColorRenderingIndex
bldg:lampColorRenderingIndex rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Lamp ;
                             rdfs:range xsd:integer ;
                             rdfs:comment " The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties."@en ;
                             rdfs:label "color rendering index"@en .


###  http://saref.linkeddata.es/def/bldg#lampColorTempeature
bldg:lampColorTempeature rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Lamp ;
                         rdfs:range xsd:float ;
                         rdfs:comment " The color temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate color temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The color temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight). Usually measured in degrees Kelvin (K)."@en ;
                         rdfs:label "color tempeature"@en .


###  http://saref.linkeddata.es/def/bldg#lampContributedLuminousFlux
bldg:lampContributedLuminousFlux rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Lamp ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp. Usually measured in Lumen (lm, Candela Steradian)."@en ;
                                 rdfs:label "contributed luminous flux"@en .


###  http://saref.linkeddata.es/def/bldg#lampLampBallastType
bldg:lampLampBallastType rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Lamp ;
                         rdfs:range xsd:string ;
                         rdfs:comment " The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz)."@en ;
                         rdfs:label "lamp ballast type"@en .


###  http://saref.linkeddata.es/def/bldg#lampLampCompensationType
bldg:lampLampCompensationType rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Lamp ;
                              rdfs:range xsd:string ;
                              rdfs:comment " Identifies the form of compensation used for power factor correction and radio suppression."@en ;
                              rdfs:label "lamp compensation type"@en .


###  http://saref.linkeddata.es/def/bldg#lampLampMaintenanceFactor
bldg:lampLampMaintenanceFactor rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Lamp ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Non recoverable losses of luminous flux of a lamp due to lamp depreciation i.e. the decreasing of light output of a luminaire due to aging and dirt."@en ;
                               rdfs:label "lamp maintenance factor"@en .


###  http://saref.linkeddata.es/def/bldg#lampLightEmitterNominalPower
bldg:lampLightEmitterNominalPower rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:Lamp ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Light emitter nominal power. Usually measured in Watts (W, J/s)."@en ;
                                  rdfs:label "light emitter nominal power"@en .


###  http://saref.linkeddata.es/def/bldg#lampSpectrumMax
bldg:lampSpectrumMax rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Lamp ;
                     rdfs:range xsd:float ;
                     rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
                     rdfs:label "spectrum max"@en .


###  http://saref.linkeddata.es/def/bldg#lampSpectrumMin
bldg:lampSpectrumMin rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Lamp ;
                     rdfs:range xsd:float ;
                     rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
                     rdfs:label "spectrum min"@en .


###  http://saref.linkeddata.es/def/bldg#outletIsPluggableOutlet
bldg:outletIsPluggableOutlet rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Outlet ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN)."@en ;
                             rdfs:label "is pluggable outlet"@en .


###  http://saref.linkeddata.es/def/bldg#outletNumberOsSockets
bldg:outletNumberOsSockets rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Outlet ;
                           rdfs:range xsd:integer ;
                           rdfs:comment " The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence."@en ;
                           rdfs:label "number os sockets"@en .


###  http://saref.linkeddata.es/def/bldg#protectiveDeviceTrippingUnitLimitingTerminalSize
bldg:protectiveDeviceTrippingUnitLimitingTerminalSize rdf:type owl:DatatypeProperty ;
                                                      rdfs:domain bldg:ProtectiveDeviceTrippingUnit ;
                                                      rdfs:range xsd:float ;
                                                      rdfs:comment " The maximum terminal size capacity of the device. Usually measured in square metre (m2)."@en ;
                                                      rdfs:label "limiting terminal size"@en .


###  http://saref.linkeddata.es/def/bldg#protectiveDeviceTrippingUnitStandard
bldg:protectiveDeviceTrippingUnitStandard rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:ProtectiveDeviceTrippingUnit ;
                                          rdfs:range xsd:string ;
                                          rdfs:comment " the designation of the Standard applicable for the definition of the characteristics of the tripping_unit."@en ;
                                          rdfs:label "standard"@en .


###  http://saref.linkeddata.es/def/bldg#pumpConnectionSize
bldg:pumpConnectionSize rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Pump ;
                        rdfs:range xsd:float ;
                        rdfs:comment " The connection size of the to and from the pump. Usually measured in millimeters (mm)."@en ;
                        rdfs:label "connection size"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowRateRangeMax
bldg:pumpFlowRateRangeMax rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Pump ;
                          rdfs:range xsd:float ;
                          rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
                          rdfs:label "flow rate range max"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowRateRangeMin
bldg:pumpFlowRateRangeMin rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Pump ;
                          rdfs:range xsd:float ;
                          rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
                          rdfs:label "flow rate range min"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowResistanceRangeMax
bldg:pumpFlowResistanceRangeMax rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Pump ;
                                rdfs:range xsd:float ;
                                rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
                                rdfs:label "flow resistance range max"@en .


###  http://saref.linkeddata.es/def/bldg#pumpFlowResistanceRangeMin
bldg:pumpFlowResistanceRangeMin rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Pump ;
                                rdfs:range xsd:float ;
                                rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
                                rdfs:label "flow resistance range min"@en .


###  http://saref.linkeddata.es/def/bldg#pumpNetPositiveSuctionHead
bldg:pumpNetPositiveSuctionHead rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Pump ;
                                rdfs:range xsd:float ;
                                rdfs:comment " Minimum liquid pressure at the pump inlet to prevent cavitation. Usually measured in Pascals (Pa, N/m2)."@en ;
                                rdfs:label "net positive suction head"@en .


###  http://saref.linkeddata.es/def/bldg#pumpNomminalRotationSpeed
bldg:pumpNomminalRotationSpeed rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Pump ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Pump rotational speed under nominal conditions. Usually measured in cycles/s."@en ;
                               rdfs:label "nomminal rotation speed"@en .


###  http://saref.linkeddata.es/def/bldg#pumpTemperatureRangeMax
bldg:pumpTemperatureRangeMax rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Pump ;
                             rdfs:range xsd:float ;
                             rdfs:comment "Allowable operational range of the fluid temperature. Usually measured in degrees Kelvin (K)."@en ;
                             rdfs:label "temperature range max"@en .


###  http://saref.linkeddata.es/def/bldg#pumpTemperatureRangeMin
bldg:pumpTemperatureRangeMin rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:Pump ;
                             rdfs:range xsd:float ;
                             rdfs:comment "Allowable operational range of the fluid temperature. Usually measured in degrees Kelvin (K)."@en ;
                             rdfs:label "temperature range min"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceIsExternal
bldg:shadingDeviceIsExternal rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:ShadingDevice ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building."@en ;
                             rdfs:label "is external"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceMechanicalOperated
bldg:shadingDeviceMechanicalOperated rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ShadingDevice ;
                                     rdfs:range xsd:boolean ;
                                     rdfs:comment " Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE)."@en ;
                                     rdfs:label "mechanical operated"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceRoughness
bldg:shadingDeviceRoughness rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:ShadingDevice ;
                            rdfs:range xsd:string ;
                            rdfs:comment " A measure of the vertical deviations of the surface."@en ;
                            rdfs:label "roughness"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceShadingDeviceType
bldg:shadingDeviceShadingDeviceType rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:ShadingDevice ;
                                    rdfs:range xsd:string ;
                                    rdfs:comment " Specifies the type of shading device."@en ;
                                    rdfs:label "shading device type"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceSolarReflectance
bldg:shadingDeviceSolarReflectance rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:ShadingDevice ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " (Rsol): The ratio of incident solar radiation that is reflected by a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
                                   rdfs:label "solar reflectance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceSolarTransmittance
bldg:shadingDeviceSolarTransmittance rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:ShadingDevice ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " (Tsol) The ratio of incident solar radiation that directly passes through a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
                                     rdfs:label "solar transmittance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceThermalTransmittance
bldg:shadingDeviceThermalTransmittance rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:ShadingDevice ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " IfcThermalTransmittanceMeasure is a measure of the rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin."@en ;
                                       rdfs:label "thermal transmittance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceVisibleLightReflectance
bldg:shadingDeviceVisibleLightReflectance rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:ShadingDevice ;
                                          rdfs:range xsd:float ;
                                          rdfs:comment " Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit."@en ;
                                          rdfs:label "visible light reflectance"@en .


###  http://saref.linkeddata.es/def/bldg#shadingDeviceVisibleLightTransmittance
bldg:shadingDeviceVisibleLightTransmittance rdf:type owl:DatatypeProperty ;
                                            rdfs:domain bldg:ShadingDevice ;
                                            rdfs:range xsd:float ;
                                            rdfs:comment " Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit."@en ;
                                            rdfs:label "visible light transmittance"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterBodyMass
bldg:spaceHeaterBodyMass rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:SpaceHeater ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Overall body mass of the heater. Usually measured in kilograms (kg) or grams (g)."@en ;
                         rdfs:label "body mass"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterEnergySource
bldg:spaceHeaterEnergySource rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:SpaceHeater ;
                             rdfs:range xsd:string ;
                             rdfs:comment "Enumeration defining the energy source or fuel combusted to generate heat if applicable. Note: hydronic heaters shall use UNSET, dual-use hydronic/electric heaters shall use ELECTRICITY."@en ;
                             rdfs:label "energy source"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterHeatTransferDimension
bldg:spaceHeaterHeatTransferDimension rdf:type owl:DatatypeProperty ;
                                      rdfs:domain bldg:SpaceHeater ;
                                      rdfs:range xsd:string ;
                                      rdfs:comment "Indicates how heat is transmitted according to the shape of the space heater."@en ;
                                      rdfs:label "heat transfer dimension"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterHeatTransferMedium
bldg:spaceHeaterHeatTransferMedium rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:SpaceHeater ;
                                   rdfs:range xsd:string ;
                                   rdfs:comment "Enumeration defining the heat transfer medium if applicable."@en ;
                                   rdfs:label "heat transfer medium"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterNumberOfPanels
bldg:spaceHeaterNumberOfPanels rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:SpaceHeater ;
                               rdfs:range xsd:integer ;
                               rdfs:comment " Number of panels."@en ;
                               rdfs:label "number of panels"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterNumberOfSections
bldg:spaceHeaterNumberOfSections rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:SpaceHeater ;
                                 rdfs:range xsd:integer ;
                                 rdfs:comment " Number of vertical sections, measured in the direction of flow."@en ;
                                 rdfs:label "number of sections"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterOutputCapacity
bldg:spaceHeaterOutputCapacity rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:SpaceHeater ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Total nominal heat output as listed by the manufacturer. Usually measured in Watts (W, J/s)."@en ;
                               rdfs:label "output capacity"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterPlacementType
bldg:spaceHeaterPlacementType rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:SpaceHeater ;
                              rdfs:range xsd:string ;
                              rdfs:comment "Indicates how the space heater is designed to be placed. "@en ;
                              rdfs:label "placement type"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterTemperatureClassification
bldg:spaceHeaterTemperatureClassification rdf:type owl:DatatypeProperty ;
                                          rdfs:domain bldg:SpaceHeater ;
                                          rdfs:range xsd:string ;
                                          rdfs:comment "Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam."@en ;
                                          rdfs:label "temperature classification"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterThermalEfficiency
bldg:spaceHeaterThermalEfficiency rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:SpaceHeater ;
                                  rdfs:range xsd:float ;
                                  rdfs:comment " Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input."@en ;
                                  rdfs:label "thermal efficiency"@en .


###  http://saref.linkeddata.es/def/bldg#spaceHeaterThermalMassHeatCapacity
bldg:spaceHeaterThermalMassHeatCapacity rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:SpaceHeater ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment " Product of component mass and specific heat."@en ;
                                        rdfs:label "thermal mass heat capacity"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceHasLock
bldg:switchingDeviceHasLock rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:SwitchingDevice ;
                            rdfs:range xsd:boolean ;
                            rdfs:comment " Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE)."@en ;
                            rdfs:label "has lock"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceIsIlluminated
bldg:switchingDeviceIsIlluminated rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:SwitchingDevice ;
                                  rdfs:range xsd:boolean ;
                                  rdfs:comment " An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE)."@en ;
                                  rdfs:label "is illuminated"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceLegend
bldg:switchingDeviceLegend rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:SwitchingDevice ;
                           rdfs:range xsd:string ;
                           rdfs:comment " A text inscribed or applied to the switch as a legend to indicate purpose or function."@en ;
                           rdfs:label "legend"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceNumberOfGangs
bldg:switchingDeviceNumberOfGangs rdf:type owl:DatatypeProperty ;
                                  rdfs:domain bldg:SwitchingDevice ;
                                  rdfs:range xsd:integer ;
                                  rdfs:comment " Number of gangs/buttons on this switch."@en ;
                                  rdfs:label "number of gangs"@en .


###  http://saref.linkeddata.es/def/bldg#switchingDeviceSwitchFunction
bldg:switchingDeviceSwitchFunction rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:SwitchingDevice ;
                                   rdfs:range xsd:string ;
                                   rdfs:comment "Indicates types of switches which differs in functionality."@en ;
                                   rdfs:label "switch function"@en .


###  http://saref.linkeddata.es/def/bldg#tankAccessType
bldg:tankAccessType rdf:type owl:DatatypeProperty ;
                    rdfs:domain bldg:Tank ;
                    rdfs:range xsd:string ;
                    rdfs:comment "Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole."@en ;
                    rdfs:label "access type"@en .


###  http://saref.linkeddata.es/def/bldg#tankEffectiveCapacity
bldg:tankEffectiveCapacity rdf:type owl:DatatypeProperty ;
                           rdfs:domain bldg:Tank ;
                           rdfs:range xsd:float ;
                           rdfs:comment " The total effective or actual volumetric capacity of the tank. Usually measured in cubic metre (m3).B3"@en ;
                           rdfs:label "effective capacity"@en .


###  http://saref.linkeddata.es/def/bldg#tankEndShapeType
bldg:tankEndShapeType rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Tank ;
                      rdfs:range xsd:string ;
                      rdfs:comment "Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5"@en ;
                      rdfs:label "end shape type"@en .


###  http://saref.linkeddata.es/def/bldg#tankFirstCurvatureRadius
bldg:tankFirstCurvatureRadius rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:Tank ;
                              rdfs:range xsd:float ;
                              rdfs:comment " FirstCurvatureRadius should be defined as the base or left side radius of curvature value. Usually measured in millimeters (mm)."@en ;
                              rdfs:label "first curvature radius"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalCapacity
bldg:tankNominalCapacity rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Tank ;
                         rdfs:range xsd:float ;
                         rdfs:comment " The total nominal or design volumetric capacity of the tank. Usually measured in cubic metre (m3)."@en ;
                         rdfs:label "nominal capacity"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalDepth
bldg:tankNominalDepth rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:Tank ;
                      rdfs:range xsd:float ;
                      rdfs:comment " The nominal depth of the tank. Note: Not required for a horizontal cylindrical tank. Usually measured in millimeters (mm)."@en ;
                      rdfs:label "nominal depth"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalLengthOrDiameter
bldg:tankNominalLengthOrDiameter rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Tank ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "nominal length or diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tankNominalWidthOrDiameter
bldg:tankNominalWidthOrDiameter rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:Tank ;
                                rdfs:range xsd:float ;
                                rdfs:comment " The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank. Note: Not required for a vertical cylindrical tank. Usually measured in millimeters (mm)."@en ;
                                rdfs:label "nominal width or diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tankNumberOfSections
bldg:tankNumberOfSections rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Tank ;
                          rdfs:range xsd:integer ;
                          rdfs:comment " Number of sections used in the construction of the tank. Default is 1. Note: All sections assumed to be the same size."@en ;
                          rdfs:label "number of sections"@en .


###  http://saref.linkeddata.es/def/bldg#tankOperatingWight
bldg:tankOperatingWight rdf:type owl:DatatypeProperty ;
                        rdfs:domain bldg:Tank ;
                        rdfs:range xsd:float ;
                        rdfs:comment " Operating weight of the tank including all of its contents. Usually measured in kilograms (kg) or grams (g)."@en ;
                        rdfs:label "operating wight"@en .


###  http://saref.linkeddata.es/def/bldg#tankPatternType
bldg:tankPatternType rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Tank ;
                     rdfs:range xsd:string ;
                     rdfs:comment "Defines the types of pattern (or shape of a tank that may be specified."@en ;
                     rdfs:label "pattern type"@en .


###  http://saref.linkeddata.es/def/bldg#tankSecondCurvatureRadius
bldg:tankSecondCurvatureRadius rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Tank ;
                               rdfs:range xsd:float ;
                               rdfs:comment " SecondCurvatureRadius should be defined as the top or right side radius of curvature value. Usually measured in millimeters (mm)."@en ;
                               rdfs:label "second curvature radius"@en .


###  http://saref.linkeddata.es/def/bldg#tankStorageType
bldg:tankStorageType rdf:type owl:DatatypeProperty ;
                     rdfs:domain bldg:Tank ;
                     rdfs:range xsd:string ;
                     rdfs:comment "Defines the general material category intended to be stored."@en ;
                     rdfs:label "storage type"@en .


###  http://saref.linkeddata.es/def/bldg#transformerImaginaryImpedanceRatio
bldg:transformerImaginaryImpedanceRatio rdf:type owl:DatatypeProperty ;
                                        rdfs:domain bldg:Transformer ;
                                        rdfs:range xsd:float ;
                                        rdfs:comment " The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
                                        rdfs:label "imaginary impedance ratio"@en .


###  http://saref.linkeddata.es/def/bldg#transformerIsNeutralPrimaryTerminalAvailable
bldg:transformerIsNeutralPrimaryTerminalAvailable rdf:type owl:DatatypeProperty ;
                                                  rdfs:domain bldg:Transformer ;
                                                  rdfs:range xsd:boolean ;
                                                  rdfs:comment " An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
                                                  rdfs:label "is neutral primary terminal available"@en .


###  http://saref.linkeddata.es/def/bldg#transformerIsNeutralSecondaryTerminalAvailable
bldg:transformerIsNeutralSecondaryTerminalAvailable rdf:type owl:DatatypeProperty ;
                                                    rdfs:domain bldg:Transformer ;
                                                    rdfs:range xsd:boolean ;
                                                    rdfs:comment " An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
                                                    rdfs:label "is neutral secondary terminal available"@en .


###  http://saref.linkeddata.es/def/bldg#transformerMaximumApparentPower
bldg:transformerMaximumApparentPower rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Transformer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " Maximum apparent power/capacity in VA (volt ampere). Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "maximum apparent power"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryApparentPower
bldg:transformerPrimaryApparentPower rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Transformer ;
                                     rdfs:range xsd:float ;
                                     rdfs:comment " The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side. Usually measured in Watts (W, J/s)."@en ;
                                     rdfs:label "primary apparent power"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryCurrent
bldg:transformerPrimaryCurrent rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Transformer ;
                               rdfs:range xsd:float ;
                               rdfs:comment " The current that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Ampere (A)."@en ;
                               rdfs:label "primary current"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryFrequency
bldg:transformerPrimaryFrequency rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Transformer ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The frequency that is going to be transformed and that runs into the transformer on the primary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
                                 rdfs:label "primary frequency"@en .


###  http://saref.linkeddata.es/def/bldg#transformerPrimaryVoltage
bldg:transformerPrimaryVoltage rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:Transformer ;
                               rdfs:range xsd:float ;
                               rdfs:comment " The voltage that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Volts (V, W/A)."@en ;
                               rdfs:label "primary voltage"@en .


###  http://saref.linkeddata.es/def/bldg#transformerRealImpedanceRatio
bldg:transformerRealImpedanceRatio rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Transformer ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
                                   rdfs:label "real impedance ratio"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryApparentPower
bldg:transformerSecondaryApparentPower rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Transformer ;
                                       rdfs:range xsd:float ;
                                       rdfs:comment " The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side. Usually measured in Watts (W, J/s)."@en ;
                                       rdfs:label "secondary apparent power"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryCurrent
bldg:transformerSecondaryCurrent rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Transformer ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The current that has been transformed and is running out of the transformer on the secondary side. Usually measured in Ampere (A)."@en ;
                                 rdfs:label "secondary current"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryCurrentType
bldg:transformerSecondaryCurrentType rdf:type owl:DatatypeProperty ;
                                     rdfs:domain bldg:Transformer ;
                                     rdfs:range xsd:string ;
                                     rdfs:comment " A list of the secondary current types that can result from transformer output."@en ;
                                     rdfs:label "secondary current type"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryFrequency
bldg:transformerSecondaryFrequency rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:Transformer ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " The frequency that has been transformed and is running out of the transformer on the secondary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
                                   rdfs:label "secondary frequency"@en .


###  http://saref.linkeddata.es/def/bldg#transformerSecondaryVoltage
bldg:transformerSecondaryVoltage rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:Transformer ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " The voltage that has been transformed and is running out of the transformer on the secondary side. Usually measured in Volts (V, W/A)."@en ;
                                 rdfs:label "secondary voltage"@en .


###  http://saref.linkeddata.es/def/bldg#transformerShortCircuitVoltageImaginaryPart
bldg:transformerShortCircuitVoltageImaginaryPart rdf:type owl:DatatypeProperty ;
                                                 rdfs:domain bldg:Transformer ;
                                                 rdfs:range xsd:float ;
                                                 rdfs:comment " A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
                                                 rdfs:label "short circuit voltage imaginary part"@en .


###  http://saref.linkeddata.es/def/bldg#transformerShortCircuitVoltageRealPart
bldg:transformerShortCircuitVoltageRealPart rdf:type owl:DatatypeProperty ;
                                            rdfs:domain bldg:Transformer ;
                                            rdfs:range xsd:float ;
                                            rdfs:comment " A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
                                            rdfs:label "short circuit voltage real part"@en .


###  http://saref.linkeddata.es/def/bldg#transformerTransformerVectorGroup
bldg:transformerTransformerVectorGroup rdf:type owl:DatatypeProperty ;
                                       rdfs:domain bldg:Transformer ;
                                       rdfs:range xsd:string ;
                                       rdfs:comment "List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers."@en ;
                                       rdfs:label "transformer vector group"@en .


###  http://saref.linkeddata.es/def/bldg#transportElementCapacityPeople
bldg:transportElementCapacityPeople rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:TransportElement ;
                                    rdfs:range xsd:positiveInteger ;
                                    rdfs:comment " capacity of the transportation element measured in numbers of person."@en ;
                                    rdfs:label "capacity people"@en .


###  http://saref.linkeddata.es/def/bldg#transportElementCapacityWeight
bldg:transportElementCapacityWeight rdf:type owl:DatatypeProperty ;
                                    rdfs:domain bldg:TransportElement ;
                                    rdfs:range xsd:float ;
                                    rdfs:comment " Capacity of the transport element measured by weight. Usually measured in kilograms (kg) or grams (g)."@en ;
                                    rdfs:label "capacity weight"@en .


###  http://saref.linkeddata.es/def/bldg#transportElementFireExit
bldg:transportElementFireExit rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:TransportElement ;
                              rdfs:range xsd:boolean ;
                              rdfs:comment " Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes."@en ;
                              rdfs:label "fire exit"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleFoulingFactor
bldg:tubeBundleFoulingFactor rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:TubeBundle ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
                             rdfs:label "fouling factor"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleHasTurbulator
bldg:tubeBundleHasTurbulator rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:TubeBundle ;
                             rdfs:range xsd:boolean ;
                             rdfs:comment " TRUE if the tube has a turbulator, FALSE if it does not."@en ;
                             rdfs:label "has turbulator"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleHorizontalSpacing
bldg:tubeBundleHorizontalSpacing rdf:type owl:DatatypeProperty ;
                                 rdfs:domain bldg:TubeBundle ;
                                 rdfs:range xsd:float ;
                                 rdfs:comment " Horizontal spacing between tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
                                 rdfs:label "horizontal spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleInLineRowSpacing
bldg:tubeBundleInLineRowSpacing rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:TubeBundle ;
                                rdfs:range xsd:float ;
                                rdfs:comment " In-line tube row spacing. Usually measured in millimeters (mm)."@en ;
                                rdfs:label "in line row spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleInsideDiameter
bldg:tubeBundleInsideDiameter rdf:type owl:DatatypeProperty ;
                              rdfs:domain bldg:TubeBundle ;
                              rdfs:range xsd:float ;
                              rdfs:comment " Actual inner diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
                              rdfs:label "inside diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleLength
bldg:tubeBundleLength rdf:type owl:DatatypeProperty ;
                      rdfs:domain bldg:TubeBundle ;
                      rdfs:range xsd:float ;
                      rdfs:comment " Length of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
                      rdfs:label "length"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleNominalDiameter
bldg:tubeBundleNominalDiameter rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:TubeBundle ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Nominal diameter or width of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
                               rdfs:label "nominal diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleNumberOfCircuits
bldg:tubeBundleNumberOfCircuits rdf:type owl:DatatypeProperty ;
                                rdfs:domain bldg:TubeBundle ;
                                rdfs:range xsd:integer ;
                                rdfs:comment " Number of parallel fluid tube circuits."@en ;
                                rdfs:label "number of circuits"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleNumberOfRows
bldg:tubeBundleNumberOfRows rdf:type owl:DatatypeProperty ;
                            rdfs:domain bldg:TubeBundle ;
                            rdfs:range xsd:integer ;
                            rdfs:comment " Number of tube rows in the tube bundle assembly."@en ;
                            rdfs:label "number of rows"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleOutsideDiameter
bldg:tubeBundleOutsideDiameter rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:TubeBundle ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Actual outside diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
                               rdfs:label "outside diameter"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleStaggeredRowSpacing
bldg:tubeBundleStaggeredRowSpacing rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:TubeBundle ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Staggered tube row spacing. Usually measured in millimeters (mm)."@en ;
                                   rdfs:label "staggered row spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleThermalConductivity
bldg:tubeBundleThermalConductivity rdf:type owl:DatatypeProperty ;
                                   rdfs:domain bldg:TubeBundle ;
                                   rdfs:range xsd:float ;
                                   rdfs:comment " Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
                                   rdfs:label "thermal conductivity"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleVerticalSpacing
bldg:tubeBundleVerticalSpacing rdf:type owl:DatatypeProperty ;
                               rdfs:domain bldg:TubeBundle ;
                               rdfs:range xsd:float ;
                               rdfs:comment " Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm)."@en ;
                               rdfs:label "vertical spacing"@en .


###  http://saref.linkeddata.es/def/bldg#tubeBundleVolumen
bldg:tubeBundleVolumen rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:TubeBundle ;
                       rdfs:range xsd:float ;
                       rdfs:comment " Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3)."@en ;
                       rdfs:label "volumen"@en .


###  http://saref.linkeddata.es/def/bldg#valveCloseOffRating
bldg:valveCloseOffRating rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Valve ;
                         rdfs:range xsd:float ;
                         rdfs:comment " Close off rating. Usually measured in Pascals (Pa, N/m2)."@en ;
                         rdfs:label "close off rating"@en .


###  http://saref.linkeddata.es/def/bldg#valveFlowCoefficient
bldg:valveFlowCoefficient rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Valve ;
                          rdfs:range xsd:float ;
                          rdfs:comment " Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve."@en ;
                          rdfs:label "flow coefficient"@en .


###  http://saref.linkeddata.es/def/bldg#valveSize
bldg:valveSize rdf:type owl:DatatypeProperty ;
               rdfs:domain bldg:Valve ;
               rdfs:range xsd:float ;
               rdfs:comment " The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.). Usually measured in millimeters (mm)."@en ;
               rdfs:label "size"@en .


###  http://saref.linkeddata.es/def/bldg#valveTestPressure
bldg:valveTestPressure rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Valve ;
                       rdfs:range xsd:float ;
                       rdfs:comment " The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2)."@en ;
                       rdfs:label "test pressure"@en .


###  http://saref.linkeddata.es/def/bldg#valveValveMechanism
bldg:valveValveMechanism rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Valve ;
                         rdfs:range xsd:string ;
                         rdfs:comment "The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal."@en ;
                         rdfs:label "valve mechanism"@en .


###  http://saref.linkeddata.es/def/bldg#valveValveOperation
bldg:valveValveOperation rdf:type owl:DatatypeProperty ;
                         rdfs:domain bldg:Valve ;
                         rdfs:range xsd:string ;
                         rdfs:comment "The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve."@en ;
                         rdfs:label "valve operation"@en .


###  http://saref.linkeddata.es/def/bldg#valveValvePattern
bldg:valveValvePattern rdf:type owl:DatatypeProperty ;
                       rdfs:domain bldg:Valve ;
                       rdfs:range xsd:string ;
                       rdfs:comment "The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports."@en ;
                       rdfs:label "valve pattern"@en .


###  http://saref.linkeddata.es/def/bldg#valveWorkingPressure
bldg:valveWorkingPressure rdf:type owl:DatatypeProperty ;
                          rdfs:domain bldg:Valve ;
                          rdfs:range xsd:float ;
                          rdfs:comment " The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2)."@en ;
                          rdfs:label "working pressure"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorHeight
bldg:vibrationIsolatorHeight rdf:type owl:DatatypeProperty ;
                             rdfs:domain bldg:VibrationIsolator ;
                             rdfs:range xsd:float ;
                             rdfs:comment " Height of the vibration isolator before tha application of load. Usually measured in millimeters (mm)."@en ;
                             rdfs:label "height"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorIsolatorCompressibility
bldg:vibrationIsolatorIsolatorCompressibility rdf:type owl:DatatypeProperty ;
                                              rdfs:domain bldg:VibrationIsolator ;
                                              rdfs:range xsd:float ;
                                              rdfs:comment " The compressibility of the vibration isolator."@en ;
                                              rdfs:label "isolator compressibility"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorIsolatorStaticDeflection
bldg:vibrationIsolatorIsolatorStaticDeflection rdf:type owl:DatatypeProperty ;
                                               rdfs:domain bldg:VibrationIsolator ;
                                               rdfs:range xsd:float ;
                                               rdfs:comment " Static deflection of the vibration isolator. Usually measured in millimeters (mm)."@en ;
                                               rdfs:label "isolator static deflection"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorMaximumSupportedWeight
bldg:vibrationIsolatorMaximumSupportedWeight rdf:type owl:DatatypeProperty ;
                                             rdfs:domain bldg:VibrationIsolator ;
                                             rdfs:range xsd:float ;
                                             rdfs:comment " The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g)."@en ;
                                             rdfs:label "maximum supported weight"@en .


###  http://saref.linkeddata.es/def/bldg#vibrationIsolatorVibrationTransmissibility
bldg:vibrationIsolatorVibrationTransmissibility rdf:type owl:DatatypeProperty ;
                                                rdfs:domain bldg:VibrationIsolator ;
                                                rdfs:range xsd:float ;
                                                rdfs:comment " the vibration transmissibility percentage."@en ;
                                                rdfs:label "vibration transmissibility"@en .


#################################################################
#    Classes
#################################################################

###  http://saref.linkeddata.es/def/bldg#Actuator
bldg:Actuator rdf:type owl:Class ;
              rdfs:subClassOf bldg:DistributionControlDevice ;
              rdfs:comment "An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion."@en ;
              rdfs:label "Actuator"@en ;
              rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcActuator" .


###  http://saref.linkeddata.es/def/bldg#AirToAirHeatRecovery
bldg:AirToAirHeatRecovery rdf:type owl:Class ;
                          rdfs:subClassOf bldg:EnergyConversionDevice ;
                          rdfs:comment "An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements."@en ;
                          rdfs:label "Air to air heat recovery"@en ;
                          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAirToAirHeatRecovery" .


###  http://saref.linkeddata.es/def/bldg#Alarm
bldg:Alarm rdf:type owl:Class ;
           rdfs:subClassOf bldg:DistributionControlDevice ;
           rdfs:comment """An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device.

Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms."""@en ;
           rdfs:label "Alarm"@en ;
           rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAlarm" .


###  http://saref.linkeddata.es/def/bldg#AudioVisualAppliance
bldg:AudioVisualAppliance rdf:type owl:Class ;
                          rdfs:subClassOf bldg:FlowTerminal ;
                          rdfs:comment """An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video.

Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only."""@en ;
                          rdfs:label "audio visual appliance"@en ;
                          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAudioVisualApplicance" .


###  http://saref.linkeddata.es/def/bldg#Boiler
bldg:Boiler rdf:type owl:Class ;
            rdfs:subClassOf bldg:EnergyConversionDevice ;
            rdfs:comment """\"A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications.

IfcBoiler is a vessel solely used for heating of water or other fluids. Storage vessels, such as for drinking water storage are considered as tanks and use the IfcTank entity.\""""@en ;
            rdfs:label "Boiler"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" .


###  http://saref.linkeddata.es/def/bldg#Building
bldg:Building rdf:type owl:Class ;
              rdfs:subClassOf [ rdf:type owl:Restriction ;
                                owl:onProperty bldg:isComposedBy ;
                                owl:allValuesFrom bldg:BuildingSpace
                              ] ;
              rdfs:label "Building"@en .


###  http://saref.linkeddata.es/def/bldg#BuildingDevice
bldg:BuildingDevice rdf:type owl:Class ;
                    rdfs:subClassOf bldg:BuildingObject ,
                                    bldg:Device ;
                    rdfs:label "Building device"@en .


###  http://saref.linkeddata.es/def/bldg#BuildingObject
bldg:BuildingObject rdf:type owl:Class ;
                    rdfs:label "BuildingObject"@en .


###  http://saref.linkeddata.es/def/bldg#BuildingSpace
bldg:BuildingSpace rdf:type owl:Class ;
                   rdfs:subClassOf [ rdf:type owl:Restriction ;
                                     owl:onProperty bldg:isComponentOf ;
                                     owl:allValuesFrom bldg:Building
                                   ] ;
                   rdfs:label "BuildingSpace"@en .


###  http://saref.linkeddata.es/def/bldg#Burner
bldg:Burner rdf:type owl:Class ;
            rdfs:subClassOf bldg:EnergyConversionDevice ;
            rdfs:comment "A burner is a device that converts fuel into heat through combustion. It includes gas, oil, and wood burners."@en ;
            rdfs:label "Burner"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBurner" .


###  http://saref.linkeddata.es/def/bldg#Chiller
bldg:Chiller rdf:type owl:Class ;
             rdfs:subClassOf bldg:EnergyConversionDevice ;
             rdfs:comment "A chiller is a device used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle to cool a fluid, typically water or a mixture of water and glycol. The chilled fluid is then used to cool and dehumidify air in a building."@en ;
             rdfs:label "Chiller"@en ;
             rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcChiller" .


###  http://saref.linkeddata.es/def/bldg#Coil
bldg:Coil rdf:type owl:Class ;
          rdfs:subClassOf bldg:EnergyConversionDevice ;
          rdfs:comment """A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface.

Coils may also be used for non-airflow cases such as embedded in a floor slab."""@en ;
          rdfs:label "Coil"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoil" .


###  http://saref.linkeddata.es/def/bldg#CommunicationAppliance
bldg:CommunicationAppliance rdf:type owl:Class ;
                            rdfs:subClassOf bldg:FlowTerminal ;
                            rdfs:comment """A communications appliance transmits and receives electronic or digital information as data or sound.

Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
                            rdfs:label "communication appliance"@en ;
                            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCommunicationAppliance" .


###  http://saref.linkeddata.es/def/bldg#Compressor
bldg:Compressor rdf:type owl:Class ;
                rdfs:subClassOf bldg:FlowMovingDevice ;
                rdfs:comment "A compressor is a device that compresses a fluid typically used in a refrigeration circuit."@en ;
                rdfs:label "Compressor"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCompressor" .


###  http://saref.linkeddata.es/def/bldg#Condenser
bldg:Condenser rdf:type owl:Class ;
               rdfs:subClassOf bldg:EnergyConversionDevice ;
               rdfs:comment "A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state."@en ;
               rdfs:label "Condenser"@en ;
               rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCondenser" .


###  http://saref.linkeddata.es/def/bldg#Controller
bldg:Controller rdf:type owl:Class ;
                rdfs:subClassOf bldg:DistributionControlDevice ;
                rdfs:comment """A controller is a device that monitors inputs and controls outputs within a building automation system.

A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller)."""@en ;
                rdfs:label "controller"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcController" .


###  http://saref.linkeddata.es/def/bldg#CooledBeam
bldg:CooledBeam rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again."@en ;
                rdfs:label "Cooled beam"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCooledBeam" .


###  http://saref.linkeddata.es/def/bldg#CoolingTower
bldg:CoolingTower rdf:type owl:Class ;
                  rdfs:subClassOf bldg:EnergyConversionDevice ;
                  rdfs:comment "A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation."@en ;
                  rdfs:label "Cooling tower"@en ;
                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoolingTower" .


###  http://saref.linkeddata.es/def/bldg#Damper
bldg:Damper rdf:type owl:Class ;
            rdfs:subClassOf bldg:FlowController ;
            rdfs:comment "A damper typically participates in an HVAC duct distribution system and is used to control or modulate the flow of air."@en ;
            rdfs:label "Damper"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDamper" .


###  http://saref.linkeddata.es/def/bldg#Device
bldg:Device rdf:type owl:Class ;
            rdfs:subClassOf <https://w3id.org/saref#Device> ;
            rdfs:label "Device"@en .


###  http://saref.linkeddata.es/def/bldg#DistributionControlDevice
bldg:DistributionControlDevice rdf:type owl:Class ;
                               rdfs:subClassOf bldg:DistributionDevice ;
                               rdfs:label "Distribution control device"@en .


###  http://saref.linkeddata.es/def/bldg#DistributionDevice
bldg:DistributionDevice rdf:type owl:Class ;
                        rdfs:subClassOf bldg:BuildingDevice ;
                        rdfs:label "DistributionDevice"@en .


###  http://saref.linkeddata.es/def/bldg#DistributionFlowDevice
bldg:DistributionFlowDevice rdf:type owl:Class ;
                            rdfs:subClassOf bldg:DistributionDevice ;
                            rdfs:label "DistributionFlowDevice"@en .


###  http://saref.linkeddata.es/def/bldg#DuctSilencer
bldg:DuctSilencer rdf:type owl:Class ;
                  rdfs:subClassOf bldg:FlowTreatmentDevice ;
                  rdfs:comment "A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device."@en ;
                  rdfs:label "Duct silencer"@en ;
                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDuctSilencer" .


###  http://saref.linkeddata.es/def/bldg#ElectricAppliance
bldg:ElectricAppliance rdf:type owl:Class ;
                       rdfs:subClassOf bldg:FlowTerminal ;
                       rdfs:comment """An electric appliance is a device intended for consumer usage that is powered by electricity.

Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
                       rdfs:label "electric appliance"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricAppliance" .


###  http://saref.linkeddata.es/def/bldg#ElectricFlowStorageDevice
bldg:ElectricFlowStorageDevice rdf:type owl:Class ;
                               rdfs:subClassOf bldg:FlowStorageDevice ;
                               rdfs:comment "An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released."@en ;
                               rdfs:label "Electric flow storage device"@en ;
                               rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricFlowStorageDevice" .


###  http://saref.linkeddata.es/def/bldg#ElectricGenerator
bldg:ElectricGenerator rdf:type owl:Class ;
                       rdfs:subClassOf bldg:EnergyConversionDevice ;
                       rdfs:comment "An electric generator is an engine that is a machine for converting mechanical energy into electrical energy."@en ;
                       rdfs:label "Electric generator"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricGenerator" .


###  http://saref.linkeddata.es/def/bldg#ElectricMotor
bldg:ElectricMotor rdf:type owl:Class ;
                   rdfs:subClassOf bldg:EnergyConversionDevice ;
                   rdfs:comment "An electric motor is an engine that is a machine for converting electrical energy into mechanical energy."@en ;
                   rdfs:label "Electric motor"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricMotor" .


###  http://saref.linkeddata.es/def/bldg#ElectricTimeControl
bldg:ElectricTimeControl rdf:type owl:Class ;
                         rdfs:subClassOf bldg:FlowController ;
                         rdfs:comment "An electric time control is a device that applies control to the provision or flow of electrical energy over time."@en ;
                         rdfs:label "Electric time control"@en ;
                         rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricTimeControl" .


###  http://saref.linkeddata.es/def/bldg#EnergyConversionDevice
bldg:EnergyConversionDevice rdf:type owl:Class ;
                            rdfs:subClassOf bldg:DistributionFlowDevice ;
                            rdfs:comment "The distribution flow element IfcEnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system. Its type is defined by IfcEnergyConversionDeviceType or its subtypes."@en ;
                            rdfs:label "Energy conversion device"@en ;
                            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEnergyConversionDevice" .


###  http://saref.linkeddata.es/def/bldg#Engine
bldg:Engine rdf:type owl:Class ;
            rdfs:subClassOf bldg:EnergyConversionDevice ;
            rdfs:comment "An engine is a device that converts fuel into mechanical energy through combustion."@en ;
            rdfs:label "Engine"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEngine" .


###  http://saref.linkeddata.es/def/bldg#EvaporativeCooler
bldg:EvaporativeCooler rdf:type owl:Class ;
                       rdfs:subClassOf bldg:EnergyConversionDevice ;
                       rdfs:comment "An evaporative cooler is a device that cools air by saturating it with water vapor."@en ;
                       rdfs:label "Evaporative cooler"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporativeCooler" .


###  http://saref.linkeddata.es/def/bldg#Evaporator
bldg:Evaporator rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid."@en ;
                rdfs:label "Evaporator"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporator" .


###  http://saref.linkeddata.es/def/bldg#Fan
bldg:Fan rdf:type owl:Class ;
         rdfs:subClassOf bldg:FlowMovingDevice ;
         rdfs:comment "A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system."@en ;
         rdfs:label "Fan"@en ;
         rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFan" .


###  http://saref.linkeddata.es/def/bldg#Filter
bldg:Filter rdf:type owl:Class ;
            rdfs:subClassOf bldg:FlowTreatmentDevice ;
            rdfs:comment "A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases."@en ;
            rdfs:label "Filter"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFilter" .


###  http://saref.linkeddata.es/def/bldg#FireSuppressionTerminal
bldg:FireSuppressionTerminal rdf:type owl:Class ;
                             rdfs:subClassOf bldg:FlowTerminal ;
                             rdfs:comment """A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire.

A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire."""@en ;
                             rdfs:label "Fire suppression terminal"@en ;
                             rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFireSuppressionTerminal" .


###  http://saref.linkeddata.es/def/bldg#FlowController
bldg:FlowController rdf:type owl:Class ;
                    rdfs:subClassOf bldg:DistributionFlowDevice ;
                    rdfs:comment "The distribution flow element IfcFlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays. Its type is defined by IfcFlowControllerType or subtypes."@en ;
                    rdfs:label "Flow controller"@en ;
                    rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowController" .


###  http://saref.linkeddata.es/def/bldg#FlowInstrument
bldg:FlowInstrument rdf:type owl:Class ;
                    rdfs:subClassOf bldg:DistributionControlDevice ;
                    rdfs:comment """A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points.

Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.)"""@en ;
                    rdfs:label "flow instrument"@en ;
                    rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowInstrument" .


###  http://saref.linkeddata.es/def/bldg#FlowMeter
bldg:FlowMeter rdf:type owl:Class ;
               rdfs:subClassOf bldg:FlowController ;
               rdfs:comment "A flow meter is a device that is used to measure the flow rate in a system."@en ;
               rdfs:label "Flow meter"@en ;
               rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMeter" .


###  http://saref.linkeddata.es/def/bldg#FlowMovingDevice
bldg:FlowMovingDevice rdf:type owl:Class ;
                      rdfs:subClassOf bldg:DistributionFlowDevice ;
                      rdfs:comment "The distribution flow element IfcFlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system. Its type is defined by IfcFlowMovingDeviceType or its subtypes."@en ;
                      rdfs:label "Flow moving device"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMovingDevice" .


###  http://saref.linkeddata.es/def/bldg#FlowStorageDevice
bldg:FlowStorageDevice rdf:type owl:Class ;
                       rdfs:subClassOf bldg:DistributionFlowDevice ;
                       rdfs:comment "The distribution flow element IfcFlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank). Its type is defined by IfcFlowStorageDeviceType or its subtypes."@en ;
                       rdfs:label "Flow storage device"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowStorageDevice" .


###  http://saref.linkeddata.es/def/bldg#FlowTerminal
bldg:FlowTerminal rdf:type owl:Class ;
                  rdfs:subClassOf bldg:DistributionFlowDevice ;
                  rdfs:comment "The distribution flow element IfcFlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment. Its type is defined by IfcFlowTerminalType or its subtypes."@en ;
                  rdfs:label "Flow terminal"@en ;
                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTerminal" .


###  http://saref.linkeddata.es/def/bldg#FlowTreatmentDevice
bldg:FlowTreatmentDevice rdf:type owl:Class ;
                         rdfs:subClassOf bldg:DistributionFlowDevice ;
                         rdfs:comment "The distribution flow element IfcFlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system. Its type is defined by IfcFlowTreatmentDeviceType or its subtypes."@en ;
                         rdfs:label "Flow treatment device"@en ;
                         rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTreatmentDevice" .


###  http://saref.linkeddata.es/def/bldg#HeatExchanger
bldg:HeatExchanger rdf:type owl:Class ;
                   rdfs:subClassOf bldg:EnergyConversionDevice ;
                   rdfs:comment """A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers.

IfcHeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas IfcAirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air)."""@en ;
                   rdfs:label "Heat exchanger"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHeatExchanger" .


###  http://saref.linkeddata.es/def/bldg#Humidifier
bldg:Humidifier rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "A humidifier is a device that adds moisture into the air."@en ;
                rdfs:label "Humidifier"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHumidifier" .


###  http://saref.linkeddata.es/def/bldg#Interceptor
bldg:Interceptor rdf:type owl:Class ;
                 rdfs:subClassOf bldg:FlowTreatmentDevice ;
                 rdfs:comment "An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity."@en ;
                 rdfs:label "Interceptor"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcInterceptor" .


###  http://saref.linkeddata.es/def/bldg#Lamp
bldg:Lamp rdf:type owl:Class ;
          rdfs:subClassOf bldg:FlowTerminal ;
          rdfs:comment "A lamp is an artificial light source such as a light bulb or tube."@en ;
          rdfs:label "Lamp"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcLamp" .


###  http://saref.linkeddata.es/def/bldg#MedicalDevice
bldg:MedicalDevice rdf:type owl:Class ;
                   rdfs:subClassOf bldg:FlowTerminal ;
                   rdfs:comment "A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide."@en ;
                   rdfs:label "Medical device"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcMedicalDevice" .


###  http://saref.linkeddata.es/def/bldg#Outlet
bldg:Outlet rdf:type owl:Class ;
            rdfs:subClassOf bldg:FlowTerminal ;
            rdfs:comment """An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications.

Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture."""@en ;
            rdfs:label "Outlet"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcOutlet" .


###  http://saref.linkeddata.es/def/bldg#ProtectiveDevice
bldg:ProtectiveDevice rdf:type owl:Class ;
                      rdfs:subClassOf bldg:FlowController ;
                      rdfs:comment """A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded.

A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection."""@en ;
                      rdfs:label "Protective device"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDevice" .


###  http://saref.linkeddata.es/def/bldg#ProtectiveDeviceTrippingUnit
bldg:ProtectiveDeviceTrippingUnit rdf:type owl:Class ;
                                  rdfs:subClassOf bldg:DistributionControlDevice ;
                                  rdfs:comment "A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded."@en ;
                                  rdfs:label "Protective device tripping unit"@en ;
                                  rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDeviceTrippingUnit" .


###  http://saref.linkeddata.es/def/bldg#Pump
bldg:Pump rdf:type owl:Class ;
          rdfs:subClassOf bldg:FlowMovingDevice ;
          rdfs:comment "A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system."@en ;
          rdfs:label "Pump"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcPump" .


###  http://saref.linkeddata.es/def/bldg#SanitaryTerminal
bldg:SanitaryTerminal rdf:type owl:Class ;
                      rdfs:subClassOf bldg:FlowTerminal ;
                      rdfs:comment "A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal."@en ;
                      rdfs:label "Sanitary terminal"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSanitaryTerminal" .


###  http://saref.linkeddata.es/def/bldg#Sensor
bldg:Sensor rdf:type owl:Class ;
            rdfs:subClassOf bldg:DistributionControlDevice ,
                            <https://w3id.org/saref#Sensor> ;
            rdfs:comment "A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument."@en ;
            rdfs:label "sensor"@en ;
            rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSensor" .


###  http://saref.linkeddata.es/def/bldg#ShadingDevice
bldg:ShadingDevice rdf:type owl:Class ;
                   rdfs:subClassOf bldg:BuildingDevice ;
                   rdfs:comment "Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable."@en ;
                   rdfs:label "Shading device"@en ;
                   rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcShadingDevice" .


###  http://saref.linkeddata.es/def/bldg#SolarDevice
bldg:SolarDevice rdf:type owl:Class ;
                 rdfs:subClassOf bldg:EnergyConversionDevice ;
                 rdfs:comment "A solar device converts solar radiation into other energy such as electric current or thermal energy."@en ;
                 rdfs:label "solar device"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSolarDevice" .


###  http://saref.linkeddata.es/def/bldg#SpaceHeater
bldg:SpaceHeater rdf:type owl:Class ;
                 rdfs:subClassOf bldg:FlowTerminal ;
                 rdfs:comment """Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters.

IfcUnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; IfcCoil should be used for coil-based floor heating."""@en ;
                 rdfs:label "Space heater"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSpaceHeater" .


###  http://saref.linkeddata.es/def/bldg#SwitchingDevice
bldg:SwitchingDevice rdf:type owl:Class ;
                     rdfs:subClassOf bldg:FlowController ;
                     rdfs:comment """A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity.

Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports."""@en ;
                     rdfs:label "Switching device"@en ;
                     rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSwitchingDevice" .


###  http://saref.linkeddata.es/def/bldg#Tank
bldg:Tank rdf:type owl:Class ;
          rdfs:subClassOf bldg:FlowStorageDevice ;
          rdfs:comment "A tank is a vessel or container in which a fluid or gas is stored for later use."@en ;
          rdfs:label "Tank"@en ;
          rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTank" .


###  http://saref.linkeddata.es/def/bldg#Transformer
bldg:Transformer rdf:type owl:Class ;
                 rdfs:subClassOf bldg:EnergyConversionDevice ;
                 rdfs:comment """A transformer is an inductive stationary device that transfers electrical energy from one circuit to another.

IfcTransformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: IfcController converts arbitrary signals, IfcAudioVisualAppliance converts signals for audio or video streams, and IfcCommunicationsAppliance converts signals for data or other communications usage."""@en ;
                 rdfs:label "Transformer"@en ;
                 rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransformer" .


###  http://saref.linkeddata.es/def/bldg#TransportElement
bldg:TransportElement rdf:type owl:Class ;
                      rdfs:subClassOf bldg:Device ;
                      rdfs:comment "A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The IfcTransportElement defines the occurrence of a transport element, that (if given), is expressed by the IfcTransportElementType. "@en ;
                      rdfs:label "Transport element"@en ;
                      rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransportElement" .


###  http://saref.linkeddata.es/def/bldg#TubeBundle
bldg:TubeBundle rdf:type owl:Class ;
                rdfs:subClassOf bldg:EnergyConversionDevice ;
                rdfs:comment "A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil."@en ;
                rdfs:label "Tube bundle"@en ;
                rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTubeBundle" .


###  http://saref.linkeddata.es/def/bldg#UnitaryControlElement
bldg:UnitaryControlElement rdf:type owl:Class ;
                           rdfs:subClassOf bldg:DistributionControlDevice ;
                           rdfs:comment """A unitary control element combines a number of control components into a single product, such as a thermostat or humidistat.

A unitary control element provides a housing for an aggregation of control or electrical distribution elements that, in combination, perform a singular (unitary) purpose. Each item in the aggregation may have its own geometric representation and location."""@en ;
                           rdfs:label "Unitary control element"@en ;
                           rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcUnitaryControlElement" .


###  http://saref.linkeddata.es/def/bldg#Valve
bldg:Valve rdf:type owl:Class ;
           rdfs:subClassOf bldg:FlowController ;
           rdfs:comment "A valve is used in a building services piping distribution system to control or modulate the flow of the fluid."@en ;
           rdfs:label "Valve"@en ;
           rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcValve" .


###  http://saref.linkeddata.es/def/bldg#VibrationIsolator
bldg:VibrationIsolator rdf:type owl:Class ;
                       rdfs:subClassOf bldg:Device ;
                       rdfs:comment "A vibration isolator is a device used to minimize the effects of vibration transmissibility in a building."@en ;
                       rdfs:label "Vibration isolator"@en ;
                       rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcVibrationIsolator" .


###  http://www.w3.org/2000/01/rdf-schema#Resource
rdfs:Resource rdf:type owl:Class .


###  https://w3id.org/saref#Device
<https://w3id.org/saref#Device> rdf:type owl:Class .


###  https://w3id.org/saref#Sensor
<https://w3id.org/saref#Sensor> rdf:type owl:Class .


###  Generated by the OWL API (version 4.2.6.20160910-2108) https://github.com/owlcs/owlapi