Newer
Older
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
owl:allValuesFrom bldg:Property
] ,
[ rdf:type owl:Restriction ;
owl:onProperty saref:isMeasuredIn ;
owl:allValuesFrom saref:UnitOfMeasure
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:relatesToProperty ;
owl:qualifiedCardinality "1"^^xsd:nonNegativeInteger ;
owl:onClass bldg:Property
] ,
[ rdf:type owl:Restriction ;
owl:onProperty saref:isMeasuredIn ;
owl:qualifiedCardinality "1"^^xsd:nonNegativeInteger ;
owl:onClass saref:UnitOfMeasure
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hasTimestamp ;
owl:allValuesFrom xsd:dateTime
] ,
[ rdf:type owl:Restriction ;
owl:onProperty saref:hasValue ;
owl:qualifiedCardinality "1"^^xsd:nonNegativeInteger ;
owl:onDataRange xsd:float
] ;
rdfs:label "Measurement"@en .
### http://saref.linkeddata.es/def/bldg#MedicalDevice
bldg:MedicalDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment "A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide."@en ;
rdfs:label "Medical device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcMedicalDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcmedicaldevice.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_medicaldevicetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Outlet
bldg:Outlet rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isPluggableOutlet ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOsSockets ;
owl:allValuesFrom xsd:integer
] ;
rdfs:comment """An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications.
Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture."""@en ;
rdfs:label "Outlet"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcOutlet" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcoutlet.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_outlettypecommon.htm> .
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
### http://saref.linkeddata.es/def/bldg#PhysicalObject
bldg:PhysicalObject rdf:type owl:Class ;
rdfs:subClassOf <http://www.w3.org/2003/01/geo/wgs84_pos#SpatialThing> ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:contains ;
owl:allValuesFrom bldg:PhysicalObject
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isContainedIn ;
owl:allValuesFrom [ rdf:type owl:Class ;
owl:unionOf ( bldg:BuildingSpace
bldg:PhysicalObject
)
]
] ,
[ rdf:type owl:Restriction ;
owl:onProperty <http://www.w3.org/2003/01/geo/wgs84_pos#location> ;
owl:allValuesFrom <http://www.w3.org/2003/01/geo/wgs84_pos#SpatialThing>
] ;
rdfs:label "Physical object"@en .
### http://saref.linkeddata.es/def/bldg#Property
bldg:Property rdf:type owl:Class ;
rdfs:label "Property"@en .
### http://saref.linkeddata.es/def/bldg#ProtectiveDevice
bldg:ProtectiveDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment """A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded.
A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection."""@en ;
rdfs:label "Protective device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcprotectivedevice.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_protectivedevicetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ProtectiveDeviceTrippingUnit
bldg:ProtectiveDeviceTrippingUnit rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:limitingTerminalSize ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:standard ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded."@en ;
rdfs:label "Protective device tripping unit"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDeviceTrippingUnit" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcprotectivedevicetrippingunit.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_protectivedevicetrippingunittypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Pump
bldg:Pump rdf:type owl:Class ;
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
rdfs:subClassOf bldg:FlowMovingDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:connectionSize ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:flowResistanceMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:flowResistanceMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:netPositiveSuctionHead ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nomminalRotationSpeed ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:pumpFlowRateMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:pumpFlowRateMin ;
owl:allValuesFrom bldg:Measurement
] ;
rdfs:comment "A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system."@en ;
rdfs:label "Pump"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcPump" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcpump.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_pumptypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#SanitaryTerminal
bldg:SanitaryTerminal rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment "A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal."@en ;
rdfs:label "Sanitary terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSanitaryTerminal" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/lexical/ifcsanitaryterminal.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/pset/pset_sanitaryterminaltypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Sensor
bldg:Sensor rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ,
rdfs:comment "A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument."@en ;
rdfs:label "sensor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSensor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcsensor.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_sensortypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ShadingDevice
bldg:ShadingDevice rdf:type owl:Class ;
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
rdfs:subClassOf bldg:BuildingDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:solarReflectance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:solarTransmittance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:thermalTransmittance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:visibleLightReflectance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:visibleLightTransmittance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isExternal ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:mechanicalOperated ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:roughness ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:shadingDeviceType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable."@en ;
rdfs:label "Shading device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcShadingDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgelements/lexical/ifcshadingdevice.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgelements/pset/pset_shadingdevicecommon.htm> .
### http://saref.linkeddata.es/def/bldg#SolarDevice
bldg:SolarDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A solar device converts solar radiation into other energy such as electric current or thermal energy."@en ;
rdfs:label "solar device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSolarDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcsolardevicetypeenum.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_solardevicetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#SpaceHeater
bldg:SpaceHeater rdf:type owl:Class ;
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
rdfs:subClassOf bldg:FlowTerminal ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:bodyMass ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:outputCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:thermalEfficiency ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:thermalMassHeatCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:energySource ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:heatTransferDimension ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:heatTransferMedium ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfPanels ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfSections ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:placementType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:temperatureClassification ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment """Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters.
UnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; Coil should be used for coil-based floor heating."""@en ;
rdfs:label "Space heater"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSpaceHeater" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcspaceheater.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_spaceheatertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#SwitchingDevice
bldg:SwitchingDevice rdf:type owl:Class ;
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
rdfs:subClassOf bldg:FlowController ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hasLock ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isIlluminated ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:legend ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfGangs ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:switchFunction ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment """A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity.
Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports."""@en ;
rdfs:label "Switching device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSwitchingDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcswitchingdevice.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_switchingdevicetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Tank
bldg:Tank rdf:type owl:Class ;
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
rdfs:subClassOf bldg:FlowStorageDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:effectiveCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:firstCurvatureRadius ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalDepth ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalLengthOrDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalVolumetricCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalWidthOrDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operatingWight ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:secondCurvatureRadius ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:accessType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:endShapeType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfSections ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:patternType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:storageType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A tank is a vessel or container in which a fluid or gas is stored for later use."@en ;
rdfs:label "Tank"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTank" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifctank.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_tanktypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Transformer
bldg:Transformer rdf:type owl:Class ;
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:apparentPowerMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:imaginaryImpedanceRatio ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:primaryApparentPower ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:primaryCurrent ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:primaryFrequency ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:primaryVoltage ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:realImpedanceRatio ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:secondaryApparentPower ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:secondaryCurrent ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:secondaryFrequency ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:secondaryVoltage ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isNeutralPrimaryTerminalAvailable ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isNeutralSecondaryTerminalAvailable ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:secondaryCurrentType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:transformerVectorGroup ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment """A transformer is an inductive stationary device that transfers electrical energy from one circuit to another.
Transformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: Controller converts arbitrary signals, AudioVisualAppliance converts signals for audio or video streams, and CommunicationsAppliance converts signals for data or other communications usage."""@en ;
rdfs:label "Transformer"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransformer" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifctransformer.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_transformertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#TransportElement
bldg:TransportElement rdf:type owl:Class ;
rdfs:subClassOf saref:Device ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:capacityWeight ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:capacityPeople ;
owl:allValuesFrom xsd:positiveInteger
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:fireExit ;
owl:allValuesFrom xsd:boolean
] ;
rdfs:comment "A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The TransportElement defines the occurrence of a transport element. "@en ;
rdfs:label "Transport element"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransportElement" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifctransportelement.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/pset/pset_transportelementcommon.htm> .
### http://saref.linkeddata.es/def/bldg#TubeBundle
bldg:TubeBundle rdf:type owl:Class ;
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:foulingFactor ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:horizontalSpacing ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:inLineRowSpacing ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:insideDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:length ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:outsideDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:staggeredRowSpacing ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:thermalConductivity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:verticalSpacing ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:volumen ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hasTurbulator ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfCircuits ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfRows ;
owl:allValuesFrom xsd:integer
] ;
rdfs:comment "A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil."@en ;
rdfs:label "Tube bundle"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTubeBundle" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifctubebundle.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_tubebundletypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#UnitaryControlElement
bldg:UnitaryControlElement rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """A unitary control element combines a number of control components into a single product, such as a thermostat or humidistat.
A unitary control element provides a housing for an aggregation of control or electrical distribution elements that, in combination, perform a singular (unitary) purpose. Each item in the aggregation may have its own geometric representation and location."""@en ;
rdfs:label "Unitary control element"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcUnitaryControlElement" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcunitarycontrolelement.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_unitarycontrolelementtypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Valve
bldg:Valve rdf:type owl:Class ;
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
rdfs:subClassOf bldg:FlowController ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:closeOffRating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:flowCoefficient ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:size ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:testPressure ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:workingPressure ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:valveMechanism ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:valveOperation ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:valvePattern ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A valve is used in a building services piping distribution system to control or modulate the flow of the fluid."@en ;
rdfs:label "Valve"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcValve" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcvalve.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_valvetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#VibrationIsolator
bldg:VibrationIsolator rdf:type owl:Class ;
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
rdfs:subClassOf saref:Device ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:height ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isolatorCompressibility ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isolatorStaticDeflection ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:supportedWeightMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:vibrationTransmissibility ;
owl:allValuesFrom bldg:Measurement
] ;
rdfs:comment "A vibration isolator is a device used to minimize the effects of vibration transmissibility in a building."@en ;
rdfs:label "Vibration isolator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcVibrationIsolator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcvibrationisolator.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_vibrationisolatortypecommon.htm> .
### http://www.w3.org/2003/01/geo/wgs84_pos#SpatialThing
<http://www.w3.org/2003/01/geo/wgs84_pos#SpatialThing> rdf:type owl:Class .
### https://w3id.org/saref#Actuator
saref:Actuator rdf:type owl:Class .
### https://w3id.org/saref#Device
saref:Device rdf:type owl:Class ;
rdfs:subClassOf bldg:PhysicalObject .
### https://w3id.org/saref#Sensor
### https://w3id.org/saref#UnitOfMeasure
saref:UnitOfMeasure rdf:type owl:Class .
### Generated by the OWL API (version 4.2.6.20160910-2108) https://github.com/owlcs/owlapi