@prefix : <http://saref.linkeddata.es/def/bldg#> .
@prefix dc: <http://purl.org/dc/elements/1.1/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix xml: <http://www.w3.org/XML/1998/namespace> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
@prefix bldg: <http://saref.linkeddata.es/def/bldg#> .
@prefix prov: <http://www.w3.org/ns/prov#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix vann: <http://purl.org/vocab/vann/> .
@prefix dcterms: <http://purl.org/dc/terms/> .
@base <http://saref.linkeddata.es/def/bldg> .
<http://saref.linkeddata.es/def/bldg> rdf:type owl:Ontology ;
owl:versionIRI <http://saref.linkeddata.es/def/v1/bldg> ;
dcterms:creator <http://purl.org/net/mpoveda> ;
rdfs:comment "This ontology extends the SAREF ontology for the building domain by defining building devices and how they are located in a building. This extension is based on the ISO 16739:2013 Industry Foundation Classes (IFC) standard for data sharing in the construction and facility management industries."@en ;
vann:preferredNamespaceUri "http://saref.linkeddata.es/def/bldg#" ;
dcterms:creator <http://www.garcia-castro.com/foaf.rdf#me> ;
vann:preferredNamespacePrefix "saref4bldg" ;
dcterms:license <http://purl.org/NET/rdflicense/cc-by4.0> ;
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
dc:title "SAREF extension for building devices"@en ;
dc:publisher <http://www.oeg-upm.net/> .
#################################################################
# Annotation properties
#################################################################
### http://purl.org/dc/terms/creator
dcterms:creator rdf:type owl:AnnotationProperty .
### http://purl.org/dc/terms/dateCopyrighted
dcterms:dateCopyrighted rdf:type owl:AnnotationProperty .
### http://purl.org/dc/terms/rightsHolder
dcterms:rightsHolder rdf:type owl:AnnotationProperty .
### http://purl.org/vocab/vann/preferredNamespacePrefix
vann:preferredNamespacePrefix rdf:type owl:AnnotationProperty .
### http://purl.org/vocab/vann/preferredNamespaceUri
vann:preferredNamespaceUri rdf:type owl:AnnotationProperty .
#################################################################
# Datatypes
#################################################################
### http://www.w3.org/2001/XMLSchema#duration
xsd:duration rdf:type rdfs:Datatype .
#################################################################
# Object Properties
#################################################################
### http://saref.linkeddata.es/def/bldg#isComponentOf
bldg:isComponentOf rdf:type owl:ObjectProperty ;
rdfs:label "isComponentOf"@en .
### http://saref.linkeddata.es/def/bldg#isComposedBy
bldg:isComposedBy rdf:type owl:ObjectProperty ;
rdfs:label "isComposedBy"@en .
#################################################################
# Data properties
#################################################################
### http://saref.linkeddata.es/def/bldg#actuatorFailPosition
bldg:actuatorFailPosition rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Actuator ;
rdfs:range xsd:string ;
rdfs:comment " Specifies the required fail-safe position of the actuator."@en ;
rdfs:label "fail position"@en .
### http://saref.linkeddata.es/def/bldg#actuatorManualOverride
bldg:actuatorManualOverride rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Actuator ;
rdfs:range xsd:boolean ;
rdfs:comment " Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator."@en ;
rdfs:label "manual override"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryHasDefrost
bldg:airToAirHeatRecoveryHasDefrost rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:boolean ;
rdfs:comment " has the heat exchanger has defrost function or not."@en ;
rdfs:label "has defrost"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryHeatTransferTypeEnum
bldg:airToAirHeatRecoveryHeatTransferTypeEnum rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:string ;
rdfs:comment "Type of heat transfer between the two air streams."@en ;
rdfs:label "heat transfer type enum"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryOperationalTemperatureRangeMax
bldg:airToAirHeatRecoveryOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operational temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryOperationalTemperatureRangeMin
bldg:airToAirHeatRecoveryOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operational temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryPrimaryAirFlowRateRangeMax
bldg:airToAirHeatRecoveryPrimaryAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:float ;
rdfs:comment "possible range of primary airflow that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "primary air flow rate range max"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoveryPrimaryAirFlowRateRangeMin
bldg:airToAirHeatRecoveryPrimaryAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:float ;
rdfs:comment "possible range of primary airflow that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "primary air flow rate range min"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoverySecondaryAirFlowRateRangeMax
bldg:airToAirHeatRecoverySecondaryAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:float ;
rdfs:comment "possible range of secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "secondary air flow rate range max"@en .
### http://saref.linkeddata.es/def/bldg#airToAirHeatRecoverySecondaryAirFlowRateRangeMin
bldg:airToAirHeatRecoverySecondaryAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AirToAirHeatRecovery ;
rdfs:range xsd:float ;
rdfs:comment "possible range of secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "secondary air flow rate range min"@en .
### http://saref.linkeddata.es/def/bldg#audioVisualApplianceAudioVolume
bldg:audioVisualApplianceAudioVolume rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AudioVisualAppliance ;
rdfs:range xsd:float ;
rdfs:comment " Indicates discrete audio volume levels and corresponding sound power offsets, if applicable. Missing values may be interpolated. Measured in watts."@en ;
rdfs:label "audio volume"@en .
### http://saref.linkeddata.es/def/bldg#audioVisualApplianceMediaSource
bldg:audioVisualApplianceMediaSource rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:AudioVisualAppliance ;
rdfs:range xsd:string ;
rdfs:comment " Indicates media sources and corresponding names of ports (IfcDistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (IfcAudioVisualAppliance)."@en ;
rdfs:label "media source"@en .
### http://saref.linkeddata.es/def/bldg#boilerEnergySource
bldg:boilerEnergySource rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the energy source or fuel cumbusted to generate heat."@en ;
rdfs:label "energy source"@en .
### http://saref.linkeddata.es/def/bldg#boilerHeatTransferSurfaceArea
bldg:boilerHeatTransferSurfaceArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment " Total heat transfer area of the vessel. Usually measured in square metre (m2)."@en ;
rdfs:label "heat transfer surface area"@en .
### http://saref.linkeddata.es/def/bldg#boilerIsWaterStorageHeater
bldg:boilerIsWaterStorageHeater rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:boolean ;
rdfs:comment " This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater."@en ;
rdfs:label "is water storage heater"@en .
### http://saref.linkeddata.es/def/bldg#boilerNominalEnergyConsumption
bldg:boilerNominalEnergyConsumption rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment " Nominal fuel consumption rate required to produce the total boiler heat output. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal energy consumption"@en .
### http://saref.linkeddata.es/def/bldg#boilerNominalPartLoadRatioMax
bldg:boilerNominalPartLoadRatioMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable part load ratio range."@en ;
rdfs:label "nominal part load ratio max"@en .
### http://saref.linkeddata.es/def/bldg#boilerNominalPartLoadRatioMin
bldg:boilerNominalPartLoadRatioMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable part load ratio range."@en ;
rdfs:label "nominal part load ratio min"@en .
### http://saref.linkeddata.es/def/bldg#boilerOperatingMode
bldg:boilerOperatingMode rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:string ;
rdfs:comment " Identifies the operating mode of the boiler."@en ;
rdfs:label "operating mode"@en .
### http://saref.linkeddata.es/def/bldg#boilerOutletTemperatureRangeMax
bldg:boilerOutletTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "outlet temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#boilerOutletTemperatureRangeMin
bldg:boilerOutletTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "outlet temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#boilerPressureRating
bldg:boilerPressureRating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment " Nominal pressure rating of the boiler as rated by the agency having jurisdiction. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "pressure rating"@en .
### http://saref.linkeddata.es/def/bldg#boilerWaterInletTemperatureRangeMax
bldg:boilerWaterInletTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "water inlet temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#boilerWaterInletTemperatureRangeMin
bldg:boilerWaterInletTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "water inlet temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#boilerWaterStorageCapacity
bldg:boilerWaterStorageCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Boiler ;
rdfs:range xsd:float ;
rdfs:comment " Water storage capacity. Usually measured in cubic metre (m3)."@en ;
rdfs:label "water storage capacity"@en .
### http://saref.linkeddata.es/def/bldg#burnerEnergySource
bldg:burnerEnergySource rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Burner ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the energy source or fuel cumbusted to generate heat."@en ;
rdfs:label "energy source"@en .
### http://saref.linkeddata.es/def/bldg#chillerNominalCapacity
bldg:chillerNominalCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Chiller ;
rdfs:range xsd:float ;
rdfs:comment " Nominal cooling capacity of chiller at standardized conditions as defined by the agency having jurisdiction. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal capacity"@en .
### http://saref.linkeddata.es/def/bldg#chillerNominalCondensingTemperature
bldg:chillerNominalCondensingTemperature rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Chiller ;
rdfs:range xsd:float ;
rdfs:comment " Chiller condensing temperature. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal condensing temperature"@en .
### http://saref.linkeddata.es/def/bldg#chillerNominalEfficiency
bldg:chillerNominalEfficiency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Chiller ;
rdfs:range xsd:float ;
rdfs:comment " Nominal chiller efficiency under nominal conditions. "@en ;
rdfs:label "nominal efficiency"@en .
### http://saref.linkeddata.es/def/bldg#chillerNominalEvaporatingTemmperature
bldg:chillerNominalEvaporatingTemmperature rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Chiller ;
rdfs:range xsd:float ;
rdfs:comment " Chiller evaporating temperature.Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal evaporating temmperature"@en .
### http://saref.linkeddata.es/def/bldg#chillerNominalHeatRejectionRate
bldg:chillerNominalHeatRejectionRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Chiller ;
rdfs:range xsd:float ;
rdfs:comment " Sum of the refrigeration effect and the heat equivalent of the power input to the compressor. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal heat rejection rate"@en .
### http://saref.linkeddata.es/def/bldg#chillerNominalPowerConsumption
bldg:chillerNominalPowerConsumption rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Chiller ;
rdfs:range xsd:float ;
rdfs:comment " Nominal total power consumption. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal power consumption"@en .
### http://saref.linkeddata.es/def/bldg#coilAirFlowRateRangeMax
bldg:coilAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment "Possible range of airflow that can be delivered. For cases where there is no airflow across the coil (e.g. electric coil in a floor slab), then the value is zero. Usually measured in m3/s."@en ;
rdfs:label "air flow rate range max"@en .
### http://saref.linkeddata.es/def/bldg#coilAirFlowRateRangeMin
bldg:coilAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment "Possible range of airflow that can be delivered. For cases where there is no airflow across the coil (e.g. electric coil in a floor slab), then the value is zero. Usually measured in m3/s."@en ;
rdfs:label "air flow rate range min"@en .
### http://saref.linkeddata.es/def/bldg#coilNominalLatentCapacity
bldg:coilNominalLatentCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment " Nominal latent capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal latent capacity"@en .
### http://saref.linkeddata.es/def/bldg#coilNominalSensibleCapacity
bldg:coilNominalSensibleCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment " Nominal sensible capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal sensible capacity"@en .
### http://saref.linkeddata.es/def/bldg#coilNominalUa
bldg:coilNominalUa rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment " Nominal UA value."@en ;
rdfs:label "nominal ua"@en .
### http://saref.linkeddata.es/def/bldg#coilOperationalTemperatureRangeMax
bldg:coilOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operational air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operational temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#coilOperationalTemperatureRangeMin
bldg:coilOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operational air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operational temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#coilPlacementType
bldg:coilPlacementType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Coil ;
rdfs:range xsd:string ;
rdfs:comment " Indicates the placement of the coil. FLOOR indicates an under floor heater (if coil type is WATERHEATINGCOIL or ELECTRICHEATINGCOIL), CEILING indicates a cooling ceiling (if coil type is WATERCOOLINGCOIL), UNIT indicates that the coil is part of a cooling or heating unit, like cooled beam, etc."@en ;
rdfs:label "placement type"@en .
### http://saref.linkeddata.es/def/bldg#compressorCompressorSpeed
bldg:compressorCompressorSpeed rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Compressor speed. Usually measured in cycles/s."@en ;
rdfs:label "compressor speed"@en .
### http://saref.linkeddata.es/def/bldg#compressorHasHotGasBypass
bldg:compressorHasHotGasBypass rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:boolean ;
rdfs:comment " Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No."@en ;
rdfs:label "has hot gas bypass"@en .
### http://saref.linkeddata.es/def/bldg#compressorIdealCapacity
bldg:compressorIdealCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Compressor capacity under ideal conditions. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "ideal capacity"@en .
### http://saref.linkeddata.es/def/bldg#compressorIdealShaftPower
bldg:compressorIdealShaftPower rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Compressor shaft power under ideal conditions. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "ideal shaft power"@en .
### http://saref.linkeddata.es/def/bldg#compressorImpellerDiameter
bldg:compressorImpellerDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Diameter of compressor impeller - used to scale performance of geometrically similar compressors. Usually measured in millimeters (mm)."@en ;
rdfs:label "impeller diameter"@en .
### http://saref.linkeddata.es/def/bldg#compressorMaximumPartLoadRatio
bldg:compressorMaximumPartLoadRatio rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Maximum part load ratio as a fraction of nominal capacity."@en ;
rdfs:label "maximum part load ratio"@en .
### http://saref.linkeddata.es/def/bldg#compressorMinimunPartLoadRatio
bldg:compressorMinimunPartLoadRatio rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Minimum part load ratio as a fraction of nominal capacity."@en ;
rdfs:label "minimun part load ratio"@en .
### http://saref.linkeddata.es/def/bldg#compressorNominalCapacity
bldg:compressorNominalCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:float ;
rdfs:comment " Compressor nameplate capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal capacity"@en .
### http://saref.linkeddata.es/def/bldg#compressorPowerSource
bldg:compressorPowerSource rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:string ;
rdfs:comment " Type of power driving the compressor."@en ;
rdfs:label "power source"@en .
### http://saref.linkeddata.es/def/bldg#compressorRefrigerantClass
bldg:compressorRefrigerantClass rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Compressor ;
rdfs:range xsd:string ;
rdfs:comment "Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
rdfs:label "refrigerant class"@en .
### http://saref.linkeddata.es/def/bldg#condenserExternalSurfaceArea
bldg:condenserExternalSurfaceArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:float ;
rdfs:comment " External surface area (both primary and secondary area). Usually measured in square metre (m2)."@en ;
rdfs:label "external surface area"@en .
### http://saref.linkeddata.es/def/bldg#condenserInternalRefrigerantVolume
bldg:condenserInternalRefrigerantVolume rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:float ;
rdfs:comment " Internal volume of condenser (refrigerant side). Usually measured in cubic metre (m3)."@en ;
rdfs:label "internal refrigerant volume"@en .
### http://saref.linkeddata.es/def/bldg#condenserInternalSurfaceArea
bldg:condenserInternalSurfaceArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:float ;
rdfs:comment " Internal surface area. Usually measured in square metre (m2)."@en ;
rdfs:label "internal surface area"@en .
### http://saref.linkeddata.es/def/bldg#condenserInternalWaterVolume
bldg:condenserInternalWaterVolume rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:float ;
rdfs:comment " Internal volume of condenser (water side). Usually measured in cubic metre (m3)."@en ;
rdfs:label "internal water volume"@en .
### http://saref.linkeddata.es/def/bldg#condenserNominalHeatTransferArea
bldg:condenserNominalHeatTransferArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:float ;
rdfs:comment " Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2)."@en ;
rdfs:label "nominal heat transfer area"@en .
### http://saref.linkeddata.es/def/bldg#condenserNominalHeatTransferCoefficient
bldg:condenserNominalHeatTransferCoefficient rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:float ;
rdfs:comment " Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin."@en ;
rdfs:label "nominal heat transfer coefficient"@en .
### http://saref.linkeddata.es/def/bldg#condenserRefrigerantClass
bldg:condenserRefrigerantClass rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Condenser ;
rdfs:range xsd:string ;
rdfs:comment "Refrigerant class used by the condenser. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
rdfs:label "refrigerant class"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamCoilLength
bldg:cooledBeamCoilLength rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Length of coil. Usually measured in millimeters (mm)."@en ;
rdfs:label "coil length"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamCoilWidth
bldg:cooledBeamCoilWidth rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Width of coil. Usually measured in millimeters (mm"@en ;
rdfs:label "coil width"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamFinishColor
bldg:cooledBeamFinishColor rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:string ;
rdfs:comment " Finish color for cooled beam."@en ;
rdfs:label "finish color"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamIntegratedLightingType
bldg:cooledBeamIntegratedLightingType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:string ;
rdfs:comment "Integrated lighting in cooled beam."@en ;
rdfs:label "integrated lighting type"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamIsFreeHanging
bldg:cooledBeamIsFreeHanging rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:boolean ;
rdfs:comment " Is it free hanging type (not mounted in a false ceiling)?"@en ;
rdfs:label "is free hanging"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalCoolingCapacity
bldg:cooledBeamNominalCoolingCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal cooling capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal cooling capacity"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalHeatingCapacity
bldg:cooledBeamNominalHeatingCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal heating capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal heating capacity"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalReturnWaterTemperatureCooling
bldg:cooledBeamNominalReturnWaterTemperatureCooling rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal return water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal return water temperature cooling"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalReturnWaterTemperatureHeating
bldg:cooledBeamNominalReturnWaterTemperatureHeating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal return water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal return water temperature heating"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalSorroundingHumidityCooling
bldg:cooledBeamNominalSorroundingHumidityCooling rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal surrounding humidity (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal sorrounding humidity cooling"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalSorroundingTemperatureCooling
bldg:cooledBeamNominalSorroundingTemperatureCooling rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal surrounding temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal sorrounding temperature cooling"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalSorroundingTemperatureHeating
bldg:cooledBeamNominalSorroundingTemperatureHeating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal surrounding temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal sorrounding temperature heating"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalSupplyWaterTemperatureCooling
bldg:cooledBeamNominalSupplyWaterTemperatureCooling rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal supply water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal supply water temperature cooling"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalSupplyWaterTemperatureHeating
bldg:cooledBeamNominalSupplyWaterTemperatureHeating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal supply water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal supply water temperature heating"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalWaterFlowCooling
bldg:cooledBeamNominalWaterFlowCooling rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal water flow (refers to nominal cooling capacity). Usually measured in m3/s."@en ;
rdfs:label "nominal water flow cooling"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamNominalWaterFlowHeating
bldg:cooledBeamNominalWaterFlowHeating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment " Nominal water flow (refers to nominal heating capacity). Usually measured in m3/s."@en ;
rdfs:label "nominal water flow heating"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamPipeConnectionEnum
bldg:cooledBeamPipeConnectionEnum rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:string ;
rdfs:comment "The manner in which the pipe connection is made to the cooled beam."@en ;
rdfs:label "pipe connection enum"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamWaterFlowControlSystemType
bldg:cooledBeamWaterFlowControlSystemType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:string ;
rdfs:comment " Factory fitted waterflow control system."@en ;
rdfs:label "water flow control system type"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamWaterPressureRangeMax
bldg:cooledBeamWaterPressureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "water pressure range max"@en .
### http://saref.linkeddata.es/def/bldg#cooledBeamWaterPressureRangeMin
bldg:cooledBeamWaterPressureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CooledBeam ;
rdfs:range xsd:float ;
rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "water pressure range min"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerAmbientDesignDryBulbTemperature
bldg:coolingTowerAmbientDesignDryBulbTemperature rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Ambient design dry bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "ambient design dry bulb temperature"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerAmbientDesignWetBulbTemperature
bldg:coolingTowerAmbientDesignWetBulbTemperature rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Ambient design wet bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "ambient design wet bulb temperature"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerBasinReserveVolume
bldg:coolingTowerBasinReserveVolume rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Volume between operating and overflow levels in cooling tower basin. Usually measured in cubic metre (m3)."@en ;
rdfs:label "basin reserve volume"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerCapacityControl
bldg:coolingTowerCapacityControl rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:string ;
rdfs:comment "FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty."@en ;
rdfs:label "capacity control"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerCircuitType
bldg:coolingTowerCircuitType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:string ;
rdfs:comment "OpenCircuit: Exposes water directly to the cooling atmosphere. CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger. Wet: The air stream or the heat exchange surface is evaporatively cooled. Dry: No evaporation into the air stream. DryWet: A combination of a dry tower and a wet tower."@en ;
rdfs:label "circuit type"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerControlStrategy
bldg:coolingTowerControlStrategy rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:string ;
rdfs:comment "FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature. WetBulbTempReset: The set-point is reset based on the wet-bulb temperature."@en ;
rdfs:label "control strategy"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerFlowArrangement
bldg:coolingTowerFlowArrangement rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:string ;
rdfs:comment " CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: air and water flow enter in same directions."@en ;
rdfs:label "flow arrangement"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerLiftElevationDifference
bldg:coolingTowerLiftElevationDifference rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Elevation difference between cooling tower sump and the top of the tower. Usually measured in millimeters (mm)."@en ;
rdfs:label "lift elevation difference"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerNominalCapcity
bldg:coolingTowerNominalCapcity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Nominal cooling tower capacity in terms of heat transfer rate of the cooling tower between air stream and water stream at nominal conditions. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal capcity"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerNumberOfCells
bldg:coolingTowerNumberOfCells rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:integer ;
rdfs:comment " Number of cells in one cooling tower unit."@en ;
rdfs:label "number of cells"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerOperationTemperatureRange
bldg:coolingTowerOperationTemperatureRange rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerSprayType
bldg:coolingTowerSprayType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:string ;
rdfs:comment " SprayFilled: Water is sprayed into airflow. SplashTypeFill: water cascades over successive rows of splash bars. FilmTypeFill: water flows in a thin layer over closely spaced sheets."@en ;
rdfs:label "spray type"@en .
### http://saref.linkeddata.es/def/bldg#coolingTowerWaterRequirement
bldg:coolingTowerWaterRequirement rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:CoolingTower ;
rdfs:range xsd:float ;
rdfs:comment " Make-up water requirements. Usually measured in m3/s."@en ;
rdfs:label "water requirement"@en .
### http://saref.linkeddata.es/def/bldg#damperBladeAction
bldg:damperBladeAction rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:string ;
rdfs:comment "Blade action."@en ;
rdfs:label "blade action"@en .
### http://saref.linkeddata.es/def/bldg#damperBladeEdge
bldg:damperBladeEdge rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:string ;
rdfs:comment "Blade edge."@en ;
rdfs:label "blade edge"@en .
### http://saref.linkeddata.es/def/bldg#damperBladeShape
bldg:damperBladeShape rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:string ;
rdfs:comment "Blade shape. Flat means triple V-groove."@en ;
rdfs:label "blade shape"@en .
### http://saref.linkeddata.es/def/bldg#damperBladeThickness
bldg:damperBladeThickness rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " The thickness of the damper blade. Usually measured in millimeters (mm)."@en ;
rdfs:label "blade thickness"@en .
### http://saref.linkeddata.es/def/bldg#damperCloseOffRating
bldg:damperCloseOffRating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Close off rating. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "close off rating"@en .
### http://saref.linkeddata.es/def/bldg#damperFaceArea
bldg:damperFaceArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Face area open to the airstream. Usually measured in square metre (m2)."@en ;
rdfs:label "face area"@en .
### http://saref.linkeddata.es/def/bldg#damperFrameDepth
bldg:damperFrameDepth rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " The length (or depth) of the damper frame. Usually measured in millimeters (mm)."@en ;
rdfs:label "frame depth"@en .
### http://saref.linkeddata.es/def/bldg#damperFrameThickness
bldg:damperFrameThickness rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " The thickness of the damper frame material. Usually measured in millimeters (mm)."@en ;
rdfs:label "frame thickness"@en .
### http://saref.linkeddata.es/def/bldg#damperFrameType
bldg:damperFrameType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:string ;
rdfs:comment " The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.)."@en ;
rdfs:label "frame type"@en .
### http://saref.linkeddata.es/def/bldg#damperLeakageFullyClosed
bldg:damperLeakageFullyClosed rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Leakage when fully closed. Usually measured in m3/s."@en ;
rdfs:label "leakage fully closed"@en .
### http://saref.linkeddata.es/def/bldg#damperMaximumAirFlowRate
bldg:damperMaximumAirFlowRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Maximum allowable air flow rate. Usually measured in m3/s."@en ;
rdfs:label "maximum air flow rate"@en .
### http://saref.linkeddata.es/def/bldg#damperMaximumWorkingPressure
bldg:damperMaximumWorkingPressure rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Maximum working pressure. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "maximum working pressure"@en .
### http://saref.linkeddata.es/def/bldg#damperNominalAirFlowRate
bldg:damperNominalAirFlowRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Nominal air flow rate. Usually measured in m3/s."@en ;
rdfs:label "nominal air flow rate"@en .
### http://saref.linkeddata.es/def/bldg#damperNumberOfBlades
bldg:damperNumberOfBlades rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:integer ;
rdfs:comment " Number of blades."@en ;
rdfs:label "number of blades"@en .
### http://saref.linkeddata.es/def/bldg#damperOpenPressureDrop
bldg:damperOpenPressureDrop rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Total pressure drop across damper. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "open pressure drop"@en .
### http://saref.linkeddata.es/def/bldg#damperOperation
bldg:damperOperation rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:string ;
rdfs:comment "The operational mechanism for the damper operation."@en ;
rdfs:label "operation"@en .
### http://saref.linkeddata.es/def/bldg#damperOrientation
bldg:damperOrientation rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:string ;
rdfs:comment "The intended orientation for the damper as specified by the manufacturer."@en ;
rdfs:label "orientation"@en .
### http://saref.linkeddata.es/def/bldg#damperTemperatureRangeMax
bldg:damperTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment "Temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#damperTemperatureRangeMin
bldg:damperTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment "Temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#damperTemperatureRating
bldg:damperTemperatureRating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Damper ;
rdfs:range xsd:float ;
rdfs:comment " Temperature rating. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature rating"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerAirFlowRateRangeMax
bldg:ductSilencerAirFlowRateRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment "Possible range of airflow that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "air flow rate range max"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerAirFlowRateRangeMin
bldg:ductSilencerAirFlowRateRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment "Possible range of airflow that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "air flow rate range min"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerHasExteriorInsulation
bldg:ductSilencerHasExteriorInsulation rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:boolean ;
rdfs:comment " TRUE if the silencer has exterior insulation. FALSE if it does not."@en ;
rdfs:label "has exterior insulation"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerHydraulicDiameter
bldg:ductSilencerHydraulicDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment " Hydraulic diameter. Usually measured in millimeters (mm)."@en ;
rdfs:label "hydraulic diameter"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerLength
bldg:ductSilencerLength rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment " The finished length of the silencer. Usually measured in millimeters (mm)."@en ;
rdfs:label "length"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerTemperatureRangeMax
bldg:ductSilencerTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment "Allowable minimum and maximum temperature. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerTemperatureRangeMin
bldg:ductSilencerTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment "Allowable minimum and maximum temperature. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerWeight
bldg:ductSilencerWeight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment " The weight of the silencer. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "weight"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerWorkingPressureRangeMax
bldg:ductSilencerWorkingPressureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment "Allowable minimum and maximum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "working pressure range max"@en .
### http://saref.linkeddata.es/def/bldg#ductSilencerWorkingPressureRangeMin
bldg:ductSilencerWorkingPressureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:DuctSilencer ;
rdfs:range xsd:float ;
rdfs:comment "Allowable minimum and maximum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "working pressure range min"@en .
### http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalFrequency
bldg:electricFlowStorageDeviceNominalFrequency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricFlowStorageDevice ;
rdfs:range xsd:float ;
rdfs:comment " The nominal frequency of the supply. Usually measured in cycles/s or Hertz (Hz)."@en ;
rdfs:label "nominal frequency"@en .
### http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltage
bldg:electricFlowStorageDeviceNominalSupplyVoltage rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricFlowStorageDevice ;
rdfs:range xsd:float ;
rdfs:comment " The nominal voltage of the supply. Usually measured in Volts (V, W/A)."@en ;
rdfs:label "nominal supply voltage"@en .
### http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltageOffsetMax
bldg:electricFlowStorageDeviceNominalSupplyVoltageOffsetMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricFlowStorageDevice ;
rdfs:range xsd:float ;
rdfs:comment " The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
rdfs:label "nominal supply voltage offset max"@en .
### http://saref.linkeddata.es/def/bldg#electricFlowStorageDeviceNominalSupplyVoltageOffsetMin
bldg:electricFlowStorageDeviceNominalSupplyVoltageOffsetMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricFlowStorageDevice ;
rdfs:range xsd:float ;
rdfs:comment " The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
rdfs:label "nominal supply voltage offset min"@en .
### http://saref.linkeddata.es/def/bldg#electricGeneratorElectricGeneratorEfficiency
bldg:electricGeneratorElectricGeneratorEfficiency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricGenerator ;
rdfs:range xsd:float ;
rdfs:comment " the ratio of output capacity to intake capacity."@en ;
rdfs:label "electric generator efficiency"@en .
### http://saref.linkeddata.es/def/bldg#electricGeneratorMaximumPowerOutput
bldg:electricGeneratorMaximumPowerOutput rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricGenerator ;
rdfs:range xsd:float ;
rdfs:comment " The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "maximum power output"@en .
### http://saref.linkeddata.es/def/bldg#electricGeneratorStartCurrentFactor
bldg:electricGeneratorStartCurrentFactor rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricGenerator ;
rdfs:range xsd:float ;
rdfs:comment " IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
rdfs:label "start current factor"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorElectricMotorEfficiency
bldg:electricMotorElectricMotorEfficiency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:float ;
rdfs:comment " The ratio of output capacity to intake capacity."@en ;
rdfs:label "electric motor efficiency"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorFrameSize
bldg:electricMotorFrameSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:string ;
rdfs:comment " Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard."@en ;
rdfs:label "frame size"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorHasPartWinding
bldg:electricMotorHasPartWinding rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) ."@en ;
rdfs:label "has part winding"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorIsGuarded
bldg:electricMotorIsGuarded rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE)."@en ;
rdfs:label "is guarded"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorLockedRotorCurrent
bldg:electricMotorLockedRotorCurrent rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:float ;
rdfs:comment " Input current when a motor armature is energized but not rotating. Usually measured in Ampere (A)."@en ;
rdfs:label "locked rotor current"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorMaximumPowerOutput
bldg:electricMotorMaximumPowerOutput rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:float ;
rdfs:comment " The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "maximum power output"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorMotorEnclosureType
bldg:electricMotorMotorEnclosureType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:string ;
rdfs:comment " A list of the available types of motor enclosure from which that required may be selected."@en ;
rdfs:label "motor enclosure type"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorStartCurrentFactor
bldg:electricMotorStartCurrentFactor rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:float ;
rdfs:comment " IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
rdfs:label "start current factor"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorStartingTime
bldg:electricMotorStartingTime rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:float ;
rdfs:comment " The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals."@en ;
rdfs:label "starting time"@en .
### http://saref.linkeddata.es/def/bldg#electricMotorTeTime
bldg:electricMotorTeTime rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ElectricMotor ;
rdfs:range xsd:float ;
rdfs:comment " The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device."@en ;
rdfs:label "te time"@en .
### http://saref.linkeddata.es/def/bldg#engineEnergySource
bldg:engineEnergySource rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Engine ;
rdfs:range xsd:string ;
rdfs:comment "The source of energy."@en ;
rdfs:label "energy source"@en .
### http://saref.linkeddata.es/def/bldg#evaporativeCoolerFlowArrangement
bldg:evaporativeCoolerFlowArrangement rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:EvaporativeCooler ;
rdfs:range xsd:string ;
rdfs:comment "CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: Air and water flow enter in same directions."@en ;
rdfs:label "flow arrangement"@en .
### http://saref.linkeddata.es/def/bldg#evaporativeCoolerHeatExchangeArea
bldg:evaporativeCoolerHeatExchangeArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:EvaporativeCooler ;
rdfs:range xsd:float ;
rdfs:comment " Heat exchange area. Usually measured in square metre (m2)."@en ;
rdfs:label "heat exchange area"@en .
### http://saref.linkeddata.es/def/bldg#evaporativeCoolerOperationalTemperatureRangeMax
bldg:evaporativeCoolerOperationalTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:EvaporativeCooler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operational temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#evaporativeCoolerOperationalTemperatureRangeMin
bldg:evaporativeCoolerOperationalTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:EvaporativeCooler ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operational temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#evaporativeCoolerWaterRequirement
bldg:evaporativeCoolerWaterRequirement rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:EvaporativeCooler ;
rdfs:range xsd:float ;
rdfs:comment " Make-up water requirement. Usually measured in m3/s."@en ;
rdfs:label "water requirement"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorEvaporationCoolant
bldg:evaporatorEvaporationCoolant rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:string ;
rdfs:comment "The fluid used for the coolant in the evaporator."@en ;
rdfs:label "evaporation coolant"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorEvaporationMediumType
bldg:evaporatorEvaporationMediumType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:string ;
rdfs:comment "ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant."@en ;
rdfs:label "evaporation medium type"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorExternalSurfaceArea
bldg:evaporatorExternalSurfaceArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:float ;
rdfs:comment " External surface area (both primary and secondary area). Usually measured in square metre (m2)."@en ;
rdfs:label "external surface area"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorInternalRefrigerantVolume
bldg:evaporatorInternalRefrigerantVolume rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:float ;
rdfs:comment " Internal volume of evaporator (refrigerant side). Usually measured in cubic metre (m3)."@en ;
rdfs:label "internal refrigerant volume"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorInternalSurfaceArea
bldg:evaporatorInternalSurfaceArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:float ;
rdfs:comment " Internal surface area. Usually measured in square metre (m2)."@en ;
rdfs:label "internal surface area"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorInternalWaterVolume
bldg:evaporatorInternalWaterVolume rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:float ;
rdfs:comment " Internal volume of evaporator (water side). Usually measured in cubic metre (m3)."@en ;
rdfs:label "internal water volume"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorNominalHeatTransferArea
bldg:evaporatorNominalHeatTransferArea rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:float ;
rdfs:comment " Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2)."@en ;
rdfs:label "nominal heat transfer area"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorNominalHeatTransferCoefficient
bldg:evaporatorNominalHeatTransferCoefficient rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:float ;
rdfs:comment " Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin."@en ;
rdfs:label "nominal heat transfer coefficient"@en .
### http://saref.linkeddata.es/def/bldg#evaporatorRefrigerantClass
bldg:evaporatorRefrigerantClass rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Evaporator ;
rdfs:range xsd:string ;
rdfs:comment " Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
rdfs:label "refrigerant class"@en .
### http://saref.linkeddata.es/def/bldg#fanCapacityControlType
bldg:fanCapacityControlType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:string ;
rdfs:comment "InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper."@en ;
rdfs:label "capacity control type"@en .
### http://saref.linkeddata.es/def/bldg#fanMotorDriveType
bldg:fanMotorDriveType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:string ;
rdfs:comment "Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type. "@en ;
rdfs:label "motor drive type"@en .
### http://saref.linkeddata.es/def/bldg#fanNominalAirFlowRate
bldg:fanNominalAirFlowRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment " Nominal air flow rate. Usually measured in m3/s."@en ;
rdfs:label "nominal air flow rate"@en .
### http://saref.linkeddata.es/def/bldg#fanNominalPowerRate
bldg:fanNominalPowerRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment " Nominal fan power rate.Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal power rate"@en .
### http://saref.linkeddata.es/def/bldg#fanNominalRotationSpeed
bldg:fanNominalRotationSpeed rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment " Nominal fan wheel speed. Usually measured in cycles/s."@en ;
rdfs:label "nominal rotation speed"@en .
### http://saref.linkeddata.es/def/bldg#fanNominalStaticPressure
bldg:fanNominalStaticPressure rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment " The static pressure within the air stream that the fan must overcome to insure designed circulation of air. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "nominal static pressure"@en .
### http://saref.linkeddata.es/def/bldg#fanNominalTotalPressure
bldg:fanNominalTotalPressure rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment " Nominal total pressure rise across the fan. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "nominal total pressure"@en .
### http://saref.linkeddata.es/def/bldg#fanOperationTemperatureRangeMax
bldg:fanOperationTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#fanOperationTemperatureRangeMin
bldg:fanOperationTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient air temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#fanOperationalRiterial
bldg:fanOperationalRiterial rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Fan ;
rdfs:range xsd:float ;
rdfs:comment " Time of operation at maximum operational ambient air temperature. Measured in seconds (s) or days (d) or other units of time."@en ;
rdfs:label "operational riterial"@en .
### http://saref.linkeddata.es/def/bldg#filterFinalResistance
bldg:filterFinalResistance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "final resistance"@en .
### http://saref.linkeddata.es/def/bldg#filterFlowRateRangeMax
bldg:filterFlowRateRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "flow rate range max"@en .
### http://saref.linkeddata.es/def/bldg#filterFlowRateRangeMin
bldg:filterFlowRateRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "flow rate range min"@en .
### http://saref.linkeddata.es/def/bldg#filterInitialResistance
bldg:filterInitialResistance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "initial resistance"@en .
### http://saref.linkeddata.es/def/bldg#filterNominalFilterFaceVelocity
bldg:filterNominalFilterFaceVelocity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Filter face velocity. Usually measured in m/s."@en ;
rdfs:label "nominal filter face velocity"@en .
### http://saref.linkeddata.es/def/bldg#filterNominalFlowRate
bldg:filterNominalFlowRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Nominal fluid flow rate through the filter. Usually measured in m3/s."@en ;
rdfs:label "nominal flow rate"@en .
### http://saref.linkeddata.es/def/bldg#filterNominalMediaSurfaceVelocity
bldg:filterNominalMediaSurfaceVelocity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Average fluid velocity at the media surface. Usually measured in m/s."@en ;
rdfs:label "nominal media surface velocity"@en .
### http://saref.linkeddata.es/def/bldg#filterNominalParticleGeometricMeanDiameter
bldg:filterNominalParticleGeometricMeanDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Particle geometric mean diameter associated with nominal efficiency. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal particle geometric mean diameter"@en .
### http://saref.linkeddata.es/def/bldg#filterNominalParticleGeometricStandardDeviation
bldg:filterNominalParticleGeometricStandardDeviation rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Particle geometric standard deviation associated with nominal efficiency. "@en ;
rdfs:label "nominal particle geometric standard deviation"@en .
### http://saref.linkeddata.es/def/bldg#filterNominalPressureDrop
bldg:filterNominalPressureDrop rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Total pressure drop across the filter. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "nominal pressure drop"@en .
### http://saref.linkeddata.es/def/bldg#filterOperationTemperatureRangeMax
bldg:filterOperationTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient fluid temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#filterOperationTemperatureRangeMin
bldg:filterOperationTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operation ambient fluid temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#filterWeight
bldg:filterWeight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Filter ;
rdfs:range xsd:float ;
rdfs:comment " Weight of filter. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "weight"@en .
### http://saref.linkeddata.es/def/bldg#flowMeterReadOutType
bldg:flowMeterReadOutType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:FlowMeter ;
rdfs:range xsd:string ;
rdfs:comment "Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer."@en ;
rdfs:label "read out type"@en .
### http://saref.linkeddata.es/def/bldg#flowMeterRemoteReading
bldg:flowMeterRemoteReading rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:FlowMeter ;
rdfs:range xsd:boolean ;
rdfs:comment " Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE)."@en ;
rdfs:label "remote reading"@en .
### http://saref.linkeddata.es/def/bldg#heatExchangerArrangement
bldg:heatExchangerArrangement rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:HeatExchanger ;
rdfs:range xsd:string ;
rdfs:comment "Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above."@en ;
rdfs:label "arrangement"@en .
### http://saref.linkeddata.es/def/bldg#humidifierApplication
bldg:humidifierApplication rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Humidifier ;
rdfs:range xsd:string ;
rdfs:comment "Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system."@en ;
rdfs:label "application"@en .
### http://saref.linkeddata.es/def/bldg#humidifierInternalControl
bldg:humidifierInternalControl rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Humidifier ;
rdfs:range xsd:string ;
rdfs:comment "Internal modulation control."@en ;
rdfs:label "internal control"@en .
### http://saref.linkeddata.es/def/bldg#humidifierNominalAirFlowRate
bldg:humidifierNominalAirFlowRate rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Humidifier ;
rdfs:range xsd:float ;
rdfs:comment " Nominal rate of air flow into which water vapor is added. Usually measured in m3/s."@en ;
rdfs:label "nominal air flow rate"@en .
### http://saref.linkeddata.es/def/bldg#humidifierNominalMoistureGain
bldg:humidifierNominalMoistureGain rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Humidifier ;
rdfs:range xsd:float ;
rdfs:comment " Nominal rate of water vapor added into the airstream. Usually measured in kg/s."@en ;
rdfs:label "nominal moisture gain"@en .
### http://saref.linkeddata.es/def/bldg#humidifierWaterRequirement
bldg:humidifierWaterRequirement rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Humidifier ;
rdfs:range xsd:float ;
rdfs:comment " Make-up water requirement. Usually measured in m3/s."@en ;
rdfs:label "water requirement"@en .
### http://saref.linkeddata.es/def/bldg#humidifierWeight
bldg:humidifierWeight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Humidifier ;
rdfs:range xsd:float ;
rdfs:comment " The weight of the humidifier. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "weight"@en .
### http://saref.linkeddata.es/def/bldg#interceptorCoverLength
bldg:interceptorCoverLength rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
rdfs:label "cover length"@en .
### http://saref.linkeddata.es/def/bldg#interceptorCoverWidth
bldg:interceptorCoverWidth rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " The length measured along the x-axis in the local coordinate system of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
rdfs:label "cover width"@en .
### http://saref.linkeddata.es/def/bldg#interceptorInletConnectionSize
bldg:interceptorInletConnectionSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " Size of the inlet connection. Usually measured in millimeters (mm)."@en ;
rdfs:label "inlet connection size"@en .
### http://saref.linkeddata.es/def/bldg#interceptorNominalBodyDepth
bldg:interceptorNominalBodyDepth rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " Nominal or quoted =length, measured along the z-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal body depth"@en .
### http://saref.linkeddata.es/def/bldg#interceptorNominalBodyLength
bldg:interceptorNominalBodyLength rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " Nominal or quoted length, measured along the x-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal body length"@en .
### http://saref.linkeddata.es/def/bldg#interceptorNominalBodyWidth
bldg:interceptorNominalBodyWidth rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " Nominal or quoted length, measured along the y-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal body width"@en .
### http://saref.linkeddata.es/def/bldg#interceptorOutletConnectionSize
bldg:interceptorOutletConnectionSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " Size of the outlet connection. Usually measured in millimeters (mm)."@en ;
rdfs:label "outlet connection size"@en .
### http://saref.linkeddata.es/def/bldg#interceptorVentilatingPipeSize
bldg:interceptorVentilatingPipeSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Interceptor ;
rdfs:range xsd:float ;
rdfs:comment " Size of the ventilating pipe(s). Usually measured in millimeters (mm)."@en ;
rdfs:label "ventilating pipe size"@en .
### http://saref.linkeddata.es/def/bldg#lampColorAppearance
bldg:lampColorAppearance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:string ;
rdfs:comment " In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance."@en ;
rdfs:label "color appearance"@en .
### http://saref.linkeddata.es/def/bldg#lampColorRenderingIndex
bldg:lampColorRenderingIndex rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:integer ;
rdfs:comment " The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties."@en ;
rdfs:label "color rendering index"@en .
### http://saref.linkeddata.es/def/bldg#lampColorTempeature
bldg:lampColorTempeature rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:float ;
rdfs:comment " The color temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate color temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The color temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "color tempeature"@en .
### http://saref.linkeddata.es/def/bldg#lampContributedLuminousFlux
bldg:lampContributedLuminousFlux rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:float ;
rdfs:comment " Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp. Usually measured in Lumen (lm, Candela Steradian)."@en ;
rdfs:label "contributed luminous flux"@en .
### http://saref.linkeddata.es/def/bldg#lampLampBallastType
bldg:lampLampBallastType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:string ;
rdfs:comment " The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz)."@en ;
rdfs:label "lamp ballast type"@en .
### http://saref.linkeddata.es/def/bldg#lampLampCompensationType
bldg:lampLampCompensationType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:string ;
rdfs:comment " Identifies the form of compensation used for power factor correction and radio suppression."@en ;
rdfs:label "lamp compensation type"@en .
### http://saref.linkeddata.es/def/bldg#lampLampMaintenanceFactor
bldg:lampLampMaintenanceFactor rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:float ;
rdfs:comment " Non recoverable losses of luminous flux of a lamp due to lamp depreciation i.e. the decreasing of light output of a luminaire due to aging and dirt."@en ;
rdfs:label "lamp maintenance factor"@en .
### http://saref.linkeddata.es/def/bldg#lampLightEmitterNominalPower
bldg:lampLightEmitterNominalPower rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:float ;
rdfs:comment " Light emitter nominal power. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "light emitter nominal power"@en .
### http://saref.linkeddata.es/def/bldg#lampSpectrumMax
bldg:lampSpectrumMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:float ;
rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
rdfs:label "spectrum max"@en .
### http://saref.linkeddata.es/def/bldg#lampSpectrumMin
bldg:lampSpectrumMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Lamp ;
rdfs:range xsd:float ;
rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
rdfs:label "spectrum min"@en .
### http://saref.linkeddata.es/def/bldg#outletIsPluggableOutlet
bldg:outletIsPluggableOutlet rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Outlet ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN)."@en ;
rdfs:label "is pluggable outlet"@en .
### http://saref.linkeddata.es/def/bldg#outletNumberOsSockets
bldg:outletNumberOsSockets rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Outlet ;
rdfs:range xsd:integer ;
rdfs:comment " The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence."@en ;
rdfs:label "number os sockets"@en .
### http://saref.linkeddata.es/def/bldg#protectiveDeviceTrippingUnitLimitingTerminalSize
bldg:protectiveDeviceTrippingUnitLimitingTerminalSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ProtectiveDeviceTrippingUnit ;
rdfs:range xsd:float ;
rdfs:comment " The maximum terminal size capacity of the device. Usually measured in square metre (m2)."@en ;
rdfs:label "limiting terminal size"@en .
### http://saref.linkeddata.es/def/bldg#protectiveDeviceTrippingUnitStandard
bldg:protectiveDeviceTrippingUnitStandard rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ProtectiveDeviceTrippingUnit ;
rdfs:range xsd:string ;
rdfs:comment " the designation of the Standard applicable for the definition of the characteristics of the tripping_unit."@en ;
rdfs:label "standard"@en .
### http://saref.linkeddata.es/def/bldg#pumpConnectionSize
bldg:pumpConnectionSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment " The connection size of the to and from the pump. Usually measured in millimeters (mm)."@en ;
rdfs:label "connection size"@en .
### http://saref.linkeddata.es/def/bldg#pumpFlowRateRangeMax
bldg:pumpFlowRateRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
rdfs:label "flow rate range max"@en .
### http://saref.linkeddata.es/def/bldg#pumpFlowRateRangeMin
bldg:pumpFlowRateRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
rdfs:label "flow rate range min"@en .
### http://saref.linkeddata.es/def/bldg#pumpFlowResistanceRangeMax
bldg:pumpFlowResistanceRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "flow resistance range max"@en .
### http://saref.linkeddata.es/def/bldg#pumpFlowResistanceRangeMin
bldg:pumpFlowResistanceRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "flow resistance range min"@en .
### http://saref.linkeddata.es/def/bldg#pumpNetPositiveSuctionHead
bldg:pumpNetPositiveSuctionHead rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment " Minimum liquid pressure at the pump inlet to prevent cavitation. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "net positive suction head"@en .
### http://saref.linkeddata.es/def/bldg#pumpNomminalRotationSpeed
bldg:pumpNomminalRotationSpeed rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment " Pump rotational speed under nominal conditions. Usually measured in cycles/s."@en ;
rdfs:label "nomminal rotation speed"@en .
### http://saref.linkeddata.es/def/bldg#pumpTemperatureRangeMax
bldg:pumpTemperatureRangeMax rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operational range of the fluid temperature. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature range max"@en .
### http://saref.linkeddata.es/def/bldg#pumpTemperatureRangeMin
bldg:pumpTemperatureRangeMin rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Pump ;
rdfs:range xsd:float ;
rdfs:comment "Allowable operational range of the fluid temperature. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature range min"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceIsExternal
bldg:shadingDeviceIsExternal rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building."@en ;
rdfs:label "is external"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceMechanicalOperated
bldg:shadingDeviceMechanicalOperated rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE)."@en ;
rdfs:label "mechanical operated"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceRoughness
bldg:shadingDeviceRoughness rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:string ;
rdfs:comment " A measure of the vertical deviations of the surface."@en ;
rdfs:label "roughness"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceShadingDeviceType
bldg:shadingDeviceShadingDeviceType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:string ;
rdfs:comment " Specifies the type of shading device."@en ;
rdfs:label "shading device type"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceSolarReflectance
bldg:shadingDeviceSolarReflectance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:float ;
rdfs:comment " (Rsol): The ratio of incident solar radiation that is reflected by a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
rdfs:label "solar reflectance"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceSolarTransmittance
bldg:shadingDeviceSolarTransmittance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:float ;
rdfs:comment " (Tsol) The ratio of incident solar radiation that directly passes through a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
rdfs:label "solar transmittance"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceThermalTransmittance
bldg:shadingDeviceThermalTransmittance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:float ;
rdfs:comment " IfcThermalTransmittanceMeasure is a measure of the rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin."@en ;
rdfs:label "thermal transmittance"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceVisibleLightReflectance
bldg:shadingDeviceVisibleLightReflectance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:float ;
rdfs:comment " Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit."@en ;
rdfs:label "visible light reflectance"@en .
### http://saref.linkeddata.es/def/bldg#shadingDeviceVisibleLightTransmittance
bldg:shadingDeviceVisibleLightTransmittance rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:ShadingDevice ;
rdfs:range xsd:float ;
rdfs:comment " Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit."@en ;
rdfs:label "visible light transmittance"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterBodyMass
bldg:spaceHeaterBodyMass rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:float ;
rdfs:comment " Overall body mass of the heater. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "body mass"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterEnergySource
bldg:spaceHeaterEnergySource rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the energy source or fuel combusted to generate heat if applicable. Note: hydronic heaters shall use UNSET, dual-use hydronic/electric heaters shall use ELECTRICITY."@en ;
rdfs:label "energy source"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterHeatTransferDimension
bldg:spaceHeaterHeatTransferDimension rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:string ;
rdfs:comment "Indicates how heat is transmitted according to the shape of the space heater."@en ;
rdfs:label "heat transfer dimension"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterHeatTransferMedium
bldg:spaceHeaterHeatTransferMedium rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the heat transfer medium if applicable."@en ;
rdfs:label "heat transfer medium"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterNumberOfPanels
bldg:spaceHeaterNumberOfPanels rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:integer ;
rdfs:comment " Number of panels."@en ;
rdfs:label "number of panels"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterNumberOfSections
bldg:spaceHeaterNumberOfSections rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:integer ;
rdfs:comment " Number of vertical sections, measured in the direction of flow."@en ;
rdfs:label "number of sections"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterOutputCapacity
bldg:spaceHeaterOutputCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:float ;
rdfs:comment " Total nominal heat output as listed by the manufacturer. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "output capacity"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterPlacementType
bldg:spaceHeaterPlacementType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:string ;
rdfs:comment "Indicates how the space heater is designed to be placed. "@en ;
rdfs:label "placement type"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterTemperatureClassification
bldg:spaceHeaterTemperatureClassification rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam."@en ;
rdfs:label "temperature classification"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterThermalEfficiency
bldg:spaceHeaterThermalEfficiency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:float ;
rdfs:comment " Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input."@en ;
rdfs:label "thermal efficiency"@en .
### http://saref.linkeddata.es/def/bldg#spaceHeaterThermalMassHeatCapacity
bldg:spaceHeaterThermalMassHeatCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SpaceHeater ;
rdfs:range xsd:float ;
rdfs:comment " Product of component mass and specific heat."@en ;
rdfs:label "thermal mass heat capacity"@en .
### http://saref.linkeddata.es/def/bldg#switchingDeviceHasLock
bldg:switchingDeviceHasLock rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SwitchingDevice ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE)."@en ;
rdfs:label "has lock"@en .
### http://saref.linkeddata.es/def/bldg#switchingDeviceIsIlluminated
bldg:switchingDeviceIsIlluminated rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SwitchingDevice ;
rdfs:range xsd:boolean ;
rdfs:comment " An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is illuminated"@en .
### http://saref.linkeddata.es/def/bldg#switchingDeviceLegend
bldg:switchingDeviceLegend rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SwitchingDevice ;
rdfs:range xsd:string ;
rdfs:comment " A text inscribed or applied to the switch as a legend to indicate purpose or function."@en ;
rdfs:label "legend"@en .
### http://saref.linkeddata.es/def/bldg#switchingDeviceNumberOfGangs
bldg:switchingDeviceNumberOfGangs rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SwitchingDevice ;
rdfs:range xsd:integer ;
rdfs:comment " Number of gangs/buttons on this switch."@en ;
rdfs:label "number of gangs"@en .
### http://saref.linkeddata.es/def/bldg#switchingDeviceSwitchFunction
bldg:switchingDeviceSwitchFunction rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:SwitchingDevice ;
rdfs:range xsd:string ;
rdfs:comment "Indicates types of switches which differs in functionality."@en ;
rdfs:label "switch function"@en .
### http://saref.linkeddata.es/def/bldg#tankAccessType
bldg:tankAccessType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole."@en ;
rdfs:label "access type"@en .
### http://saref.linkeddata.es/def/bldg#tankEffectiveCapacity
bldg:tankEffectiveCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " The total effective or actual volumetric capacity of the tank. Usually measured in cubic metre (m3).B3"@en ;
rdfs:label "effective capacity"@en .
### http://saref.linkeddata.es/def/bldg#tankEndShapeType
bldg:tankEndShapeType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5"@en ;
rdfs:label "end shape type"@en .
### http://saref.linkeddata.es/def/bldg#tankFirstCurvatureRadius
bldg:tankFirstCurvatureRadius rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " FirstCurvatureRadius should be defined as the base or left side radius of curvature value. Usually measured in millimeters (mm)."@en ;
rdfs:label "first curvature radius"@en .
### http://saref.linkeddata.es/def/bldg#tankNominalCapacity
bldg:tankNominalCapacity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " The total nominal or design volumetric capacity of the tank. Usually measured in cubic metre (m3)."@en ;
rdfs:label "nominal capacity"@en .
### http://saref.linkeddata.es/def/bldg#tankNominalDepth
bldg:tankNominalDepth rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " The nominal depth of the tank. Note: Not required for a horizontal cylindrical tank. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal depth"@en .
### http://saref.linkeddata.es/def/bldg#tankNominalLengthOrDiameter
bldg:tankNominalLengthOrDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal length or diameter"@en .
### http://saref.linkeddata.es/def/bldg#tankNominalWidthOrDiameter
bldg:tankNominalWidthOrDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank. Note: Not required for a vertical cylindrical tank. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal width or diameter"@en .
### http://saref.linkeddata.es/def/bldg#tankNumberOfSections
bldg:tankNumberOfSections rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:integer ;
rdfs:comment " Number of sections used in the construction of the tank. Default is 1. Note: All sections assumed to be the same size."@en ;
rdfs:label "number of sections"@en .
### http://saref.linkeddata.es/def/bldg#tankOperatingWight
bldg:tankOperatingWight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " Operating weight of the tank including all of its contents. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "operating wight"@en .
### http://saref.linkeddata.es/def/bldg#tankPatternType
bldg:tankPatternType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of pattern (or shape of a tank that may be specified."@en ;
rdfs:label "pattern type"@en .
### http://saref.linkeddata.es/def/bldg#tankSecondCurvatureRadius
bldg:tankSecondCurvatureRadius rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:float ;
rdfs:comment " SecondCurvatureRadius should be defined as the top or right side radius of curvature value. Usually measured in millimeters (mm)."@en ;
rdfs:label "second curvature radius"@en .
### http://saref.linkeddata.es/def/bldg#tankStorageType
bldg:tankStorageType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Tank ;
rdfs:range xsd:string ;
rdfs:comment "Defines the general material category intended to be stored."@en ;
rdfs:label "storage type"@en .
### http://saref.linkeddata.es/def/bldg#transformerImaginaryImpedanceRatio
bldg:transformerImaginaryImpedanceRatio rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
rdfs:label "imaginary impedance ratio"@en .
### http://saref.linkeddata.es/def/bldg#transformerIsNeutralPrimaryTerminalAvailable
bldg:transformerIsNeutralPrimaryTerminalAvailable rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:boolean ;
rdfs:comment " An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is neutral primary terminal available"@en .
### http://saref.linkeddata.es/def/bldg#transformerIsNeutralSecondaryTerminalAvailable
bldg:transformerIsNeutralSecondaryTerminalAvailable rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:boolean ;
rdfs:comment " An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is neutral secondary terminal available"@en .
### http://saref.linkeddata.es/def/bldg#transformerMaximumApparentPower
bldg:transformerMaximumApparentPower rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " Maximum apparent power/capacity in VA (volt ampere). Usually measured in Watts (W, J/s)."@en ;
rdfs:label "maximum apparent power"@en .
### http://saref.linkeddata.es/def/bldg#transformerPrimaryApparentPower
bldg:transformerPrimaryApparentPower rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "primary apparent power"@en .
### http://saref.linkeddata.es/def/bldg#transformerPrimaryCurrent
bldg:transformerPrimaryCurrent rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The current that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Ampere (A)."@en ;
rdfs:label "primary current"@en .
### http://saref.linkeddata.es/def/bldg#transformerPrimaryFrequency
bldg:transformerPrimaryFrequency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The frequency that is going to be transformed and that runs into the transformer on the primary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
rdfs:label "primary frequency"@en .
### http://saref.linkeddata.es/def/bldg#transformerPrimaryVoltage
bldg:transformerPrimaryVoltage rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The voltage that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Volts (V, W/A)."@en ;
rdfs:label "primary voltage"@en .
### http://saref.linkeddata.es/def/bldg#transformerRealImpedanceRatio
bldg:transformerRealImpedanceRatio rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
rdfs:label "real impedance ratio"@en .
### http://saref.linkeddata.es/def/bldg#transformerSecondaryApparentPower
bldg:transformerSecondaryApparentPower rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "secondary apparent power"@en .
### http://saref.linkeddata.es/def/bldg#transformerSecondaryCurrent
bldg:transformerSecondaryCurrent rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The current that has been transformed and is running out of the transformer on the secondary side. Usually measured in Ampere (A)."@en ;
rdfs:label "secondary current"@en .
### http://saref.linkeddata.es/def/bldg#transformerSecondaryCurrentType
bldg:transformerSecondaryCurrentType rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:string ;
rdfs:comment " A list of the secondary current types that can result from transformer output."@en ;
rdfs:label "secondary current type"@en .
### http://saref.linkeddata.es/def/bldg#transformerSecondaryFrequency
bldg:transformerSecondaryFrequency rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The frequency that has been transformed and is running out of the transformer on the secondary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
rdfs:label "secondary frequency"@en .
### http://saref.linkeddata.es/def/bldg#transformerSecondaryVoltage
bldg:transformerSecondaryVoltage rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " The voltage that has been transformed and is running out of the transformer on the secondary side. Usually measured in Volts (V, W/A)."@en ;
rdfs:label "secondary voltage"@en .
### http://saref.linkeddata.es/def/bldg#transformerShortCircuitVoltageImaginaryPart
bldg:transformerShortCircuitVoltageImaginaryPart rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
rdfs:label "short circuit voltage imaginary part"@en .
### http://saref.linkeddata.es/def/bldg#transformerShortCircuitVoltageRealPart
bldg:transformerShortCircuitVoltageRealPart rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:float ;
rdfs:comment " A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
rdfs:label "short circuit voltage real part"@en .
### http://saref.linkeddata.es/def/bldg#transformerTransformerVectorGroup
bldg:transformerTransformerVectorGroup rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Transformer ;
rdfs:range xsd:string ;
rdfs:comment "List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers."@en ;
rdfs:label "transformer vector group"@en .
### http://saref.linkeddata.es/def/bldg#transportElementCapacityPeople
bldg:transportElementCapacityPeople rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TransportElement ;
rdfs:range xsd:positiveInteger ;
rdfs:comment " capacity of the transportation element measured in numbers of person."@en ;
rdfs:label "capacity people"@en .
### http://saref.linkeddata.es/def/bldg#transportElementCapacityWeight
bldg:transportElementCapacityWeight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TransportElement ;
rdfs:range xsd:float ;
rdfs:comment " Capacity of the transport element measured by weight. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "capacity weight"@en .
### http://saref.linkeddata.es/def/bldg#transportElementFireExit
bldg:transportElementFireExit rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TransportElement ;
rdfs:range xsd:boolean ;
rdfs:comment " Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes."@en ;
rdfs:label "fire exit"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleFoulingFactor
bldg:tubeBundleFoulingFactor rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
rdfs:label "fouling factor"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleHasTurbulator
bldg:tubeBundleHasTurbulator rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:boolean ;
rdfs:comment " TRUE if the tube has a turbulator, FALSE if it does not."@en ;
rdfs:label "has turbulator"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleHorizontalSpacing
bldg:tubeBundleHorizontalSpacing rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Horizontal spacing between tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "horizontal spacing"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleInLineRowSpacing
bldg:tubeBundleInLineRowSpacing rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " In-line tube row spacing. Usually measured in millimeters (mm)."@en ;
rdfs:label "in line row spacing"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleInsideDiameter
bldg:tubeBundleInsideDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Actual inner diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "inside diameter"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleLength
bldg:tubeBundleLength rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Length of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "length"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleNominalDiameter
bldg:tubeBundleNominalDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Nominal diameter or width of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal diameter"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleNumberOfCircuits
bldg:tubeBundleNumberOfCircuits rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:integer ;
rdfs:comment " Number of parallel fluid tube circuits."@en ;
rdfs:label "number of circuits"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleNumberOfRows
bldg:tubeBundleNumberOfRows rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:integer ;
rdfs:comment " Number of tube rows in the tube bundle assembly."@en ;
rdfs:label "number of rows"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleOutsideDiameter
bldg:tubeBundleOutsideDiameter rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Actual outside diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "outside diameter"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleStaggeredRowSpacing
bldg:tubeBundleStaggeredRowSpacing rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Staggered tube row spacing. Usually measured in millimeters (mm)."@en ;
rdfs:label "staggered row spacing"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleThermalConductivity
bldg:tubeBundleThermalConductivity rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
rdfs:label "thermal conductivity"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleVerticalSpacing
bldg:tubeBundleVerticalSpacing rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm)."@en ;
rdfs:label "vertical spacing"@en .
### http://saref.linkeddata.es/def/bldg#tubeBundleVolumen
bldg:tubeBundleVolumen rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:TubeBundle ;
rdfs:range xsd:float ;
rdfs:comment " Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3)."@en ;
rdfs:label "volumen"@en .
### http://saref.linkeddata.es/def/bldg#valveCloseOffRating
bldg:valveCloseOffRating rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:float ;
rdfs:comment " Close off rating. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "close off rating"@en .
### http://saref.linkeddata.es/def/bldg#valveFlowCoefficient
bldg:valveFlowCoefficient rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:float ;
rdfs:comment " Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve."@en ;
rdfs:label "flow coefficient"@en .
### http://saref.linkeddata.es/def/bldg#valveSize
bldg:valveSize rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:float ;
rdfs:comment " The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.). Usually measured in millimeters (mm)."@en ;
rdfs:label "size"@en .
### http://saref.linkeddata.es/def/bldg#valveTestPressure
bldg:valveTestPressure rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:float ;
rdfs:comment " The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "test pressure"@en .
### http://saref.linkeddata.es/def/bldg#valveValveMechanism
bldg:valveValveMechanism rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:string ;
rdfs:comment "The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal."@en ;
rdfs:label "valve mechanism"@en .
### http://saref.linkeddata.es/def/bldg#valveValveOperation
bldg:valveValveOperation rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:string ;
rdfs:comment "The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve."@en ;
rdfs:label "valve operation"@en .
### http://saref.linkeddata.es/def/bldg#valveValvePattern
bldg:valveValvePattern rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:string ;
rdfs:comment "The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports."@en ;
rdfs:label "valve pattern"@en .
### http://saref.linkeddata.es/def/bldg#valveWorkingPressure
bldg:valveWorkingPressure rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:Valve ;
rdfs:range xsd:float ;
rdfs:comment " The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "working pressure"@en .
### http://saref.linkeddata.es/def/bldg#vibrationIsolatorHeight
bldg:vibrationIsolatorHeight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:VibrationIsolator ;
rdfs:range xsd:float ;
rdfs:comment " Height of the vibration isolator before tha application of load. Usually measured in millimeters (mm)."@en ;
rdfs:label "height"@en .
### http://saref.linkeddata.es/def/bldg#vibrationIsolatorIsolatorCompressibility
bldg:vibrationIsolatorIsolatorCompressibility rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:VibrationIsolator ;
rdfs:range xsd:float ;
rdfs:comment " The compressibility of the vibration isolator."@en ;
rdfs:label "isolator compressibility"@en .
### http://saref.linkeddata.es/def/bldg#vibrationIsolatorIsolatorStaticDeflection
bldg:vibrationIsolatorIsolatorStaticDeflection rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:VibrationIsolator ;
rdfs:range xsd:float ;
rdfs:comment " Static deflection of the vibration isolator. Usually measured in millimeters (mm)."@en ;
rdfs:label "isolator static deflection"@en .
### http://saref.linkeddata.es/def/bldg#vibrationIsolatorMaximumSupportedWeight
bldg:vibrationIsolatorMaximumSupportedWeight rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:VibrationIsolator ;
rdfs:range xsd:float ;
rdfs:comment " The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "maximum supported weight"@en .
### http://saref.linkeddata.es/def/bldg#vibrationIsolatorVibrationTransmissibility
bldg:vibrationIsolatorVibrationTransmissibility rdf:type owl:DatatypeProperty ;
rdfs:domain bldg:VibrationIsolator ;
rdfs:range xsd:float ;
rdfs:comment " the vibration transmissibility percentage."@en ;
rdfs:label "vibration transmissibility"@en .
#################################################################
# Classes
#################################################################
### http://saref.linkeddata.es/def/bldg#Actuator
bldg:Actuator rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment "An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion."@en ;
rdfs:label "Actuator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcActuator" .
### http://saref.linkeddata.es/def/bldg#AirToAirHeatRecovery
bldg:AirToAirHeatRecovery rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements."@en ;
rdfs:label "Air to air heat recovery"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAirToAirHeatRecovery" .
### http://saref.linkeddata.es/def/bldg#Alarm
bldg:Alarm rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device.
Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms."""@en ;
rdfs:label "Alarm"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAlarm" .
### http://saref.linkeddata.es/def/bldg#AudioVisualAppliance
bldg:AudioVisualAppliance rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video.
Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only."""@en ;
rdfs:label "audio visual appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAudioVisualApplicance" .
### http://saref.linkeddata.es/def/bldg#Boiler
bldg:Boiler rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment """\"A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications.
IfcBoiler is a vessel solely used for heating of water or other fluids. Storage vessels, such as for drinking water storage are considered as tanks and use the IfcTank entity.\""""@en ;
rdfs:label "Boiler"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" .
### http://saref.linkeddata.es/def/bldg#Building
bldg:Building rdf:type owl:Class ;
rdfs:subClassOf [ rdf:type owl:Restriction ;
owl:onProperty bldg:isComposedBy ;
owl:allValuesFrom bldg:BuildingSpace
] ;
rdfs:label "Building"@en .
### http://saref.linkeddata.es/def/bldg#BuildingDevice
bldg:BuildingDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:BuildingObject ,
bldg:Device ;
rdfs:label "Building device"@en .
### http://saref.linkeddata.es/def/bldg#BuildingObject
bldg:BuildingObject rdf:type owl:Class ;
rdfs:label "BuildingObject"@en .
### http://saref.linkeddata.es/def/bldg#BuildingSpace
bldg:BuildingSpace rdf:type owl:Class ;
rdfs:subClassOf [ rdf:type owl:Restriction ;
owl:onProperty bldg:isComponentOf ;
owl:allValuesFrom bldg:Building
] ;
rdfs:label "BuildingSpace"@en .
### http://saref.linkeddata.es/def/bldg#Burner
bldg:Burner rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A burner is a device that converts fuel into heat through combustion. It includes gas, oil, and wood burners."@en ;
rdfs:label "Burner"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBurner" .
### http://saref.linkeddata.es/def/bldg#Chiller
bldg:Chiller rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A chiller is a device used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle to cool a fluid, typically water or a mixture of water and glycol. The chilled fluid is then used to cool and dehumidify air in a building."@en ;
rdfs:label "Chiller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcChiller" .
### http://saref.linkeddata.es/def/bldg#Coil
bldg:Coil rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment """A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface.
Coils may also be used for non-airflow cases such as embedded in a floor slab."""@en ;
rdfs:label "Coil"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoil" .
### http://saref.linkeddata.es/def/bldg#CommunicationAppliance
bldg:CommunicationAppliance rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """A communications appliance transmits and receives electronic or digital information as data or sound.
Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
rdfs:label "communication appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCommunicationAppliance" .
### http://saref.linkeddata.es/def/bldg#Compressor
bldg:Compressor rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowMovingDevice ;
rdfs:comment "A compressor is a device that compresses a fluid typically used in a refrigeration circuit."@en ;
rdfs:label "Compressor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCompressor" .
### http://saref.linkeddata.es/def/bldg#Condenser
bldg:Condenser rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state."@en ;
rdfs:label "Condenser"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCondenser" .
### http://saref.linkeddata.es/def/bldg#Controller
bldg:Controller rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """A controller is a device that monitors inputs and controls outputs within a building automation system.
A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller)."""@en ;
rdfs:label "controller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcController" .
### http://saref.linkeddata.es/def/bldg#CooledBeam
bldg:CooledBeam rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again."@en ;
rdfs:label "Cooled beam"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCooledBeam" .
### http://saref.linkeddata.es/def/bldg#CoolingTower
bldg:CoolingTower rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation."@en ;
rdfs:label "Cooling tower"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoolingTower" .
### http://saref.linkeddata.es/def/bldg#Damper
bldg:Damper rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment "A damper typically participates in an HVAC duct distribution system and is used to control or modulate the flow of air."@en ;
rdfs:label "Damper"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDamper" .
### http://saref.linkeddata.es/def/bldg#Device
bldg:Device rdf:type owl:Class ;
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
rdfs:label "Device"@en .
### http://saref.linkeddata.es/def/bldg#DistributionControlDevice
bldg:DistributionControlDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionDevice ;
rdfs:label "Distribution control device"@en .
### http://saref.linkeddata.es/def/bldg#DistributionDevice
bldg:DistributionDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:BuildingDevice ;
rdfs:label "DistributionDevice"@en .
### http://saref.linkeddata.es/def/bldg#DistributionFlowDevice
bldg:DistributionFlowDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionDevice ;
rdfs:label "DistributionFlowDevice"@en .
### http://saref.linkeddata.es/def/bldg#DuctSilencer
bldg:DuctSilencer rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTreatmentDevice ;
rdfs:comment "A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device."@en ;
rdfs:label "Duct silencer"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDuctSilencer" .
### http://saref.linkeddata.es/def/bldg#ElectricAppliance
bldg:ElectricAppliance rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """An electric appliance is a device intended for consumer usage that is powered by electricity.
Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
rdfs:label "electric appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricAppliance" .
### http://saref.linkeddata.es/def/bldg#ElectricFlowStorageDevice
bldg:ElectricFlowStorageDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowStorageDevice ;
rdfs:comment "An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released."@en ;
rdfs:label "Electric flow storage device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricFlowStorageDevice" .
### http://saref.linkeddata.es/def/bldg#ElectricGenerator
bldg:ElectricGenerator rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "An electric generator is an engine that is a machine for converting mechanical energy into electrical energy."@en ;
rdfs:label "Electric generator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricGenerator" .
### http://saref.linkeddata.es/def/bldg#ElectricMotor
bldg:ElectricMotor rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "An electric motor is an engine that is a machine for converting electrical energy into mechanical energy."@en ;
rdfs:label "Electric motor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricMotor" .
### http://saref.linkeddata.es/def/bldg#ElectricTimeControl
bldg:ElectricTimeControl rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment "An electric time control is a device that applies control to the provision or flow of electrical energy over time."@en ;
rdfs:label "Electric time control"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricTimeControl" .
### http://saref.linkeddata.es/def/bldg#EnergyConversionDevice
bldg:EnergyConversionDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element IfcEnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system. Its type is defined by IfcEnergyConversionDeviceType or its subtypes."@en ;
rdfs:label "Energy conversion device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEnergyConversionDevice" .
### http://saref.linkeddata.es/def/bldg#Engine
bldg:Engine rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "An engine is a device that converts fuel into mechanical energy through combustion."@en ;
rdfs:label "Engine"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEngine" .
### http://saref.linkeddata.es/def/bldg#EvaporativeCooler
bldg:EvaporativeCooler rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "An evaporative cooler is a device that cools air by saturating it with water vapor."@en ;
rdfs:label "Evaporative cooler"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporativeCooler" .
### http://saref.linkeddata.es/def/bldg#Evaporator
bldg:Evaporator rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid."@en ;
rdfs:label "Evaporator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporator" .
### http://saref.linkeddata.es/def/bldg#Fan
bldg:Fan rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowMovingDevice ;
rdfs:comment "A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system."@en ;
rdfs:label "Fan"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFan" .
### http://saref.linkeddata.es/def/bldg#Filter
bldg:Filter rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTreatmentDevice ;
rdfs:comment "A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases."@en ;
rdfs:label "Filter"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFilter" .
### http://saref.linkeddata.es/def/bldg#FireSuppressionTerminal
bldg:FireSuppressionTerminal rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire.
A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire."""@en ;
rdfs:label "Fire suppression terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFireSuppressionTerminal" .
### http://saref.linkeddata.es/def/bldg#FlowController
bldg:FlowController rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element IfcFlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays. Its type is defined by IfcFlowControllerType or subtypes."@en ;
rdfs:label "Flow controller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowController" .
### http://saref.linkeddata.es/def/bldg#FlowInstrument
bldg:FlowInstrument rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points.
Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.)"""@en ;
rdfs:label "flow instrument"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowInstrument" .
### http://saref.linkeddata.es/def/bldg#FlowMeter
bldg:FlowMeter rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment "A flow meter is a device that is used to measure the flow rate in a system."@en ;
rdfs:label "Flow meter"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMeter" .
### http://saref.linkeddata.es/def/bldg#FlowMovingDevice
bldg:FlowMovingDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element IfcFlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system. Its type is defined by IfcFlowMovingDeviceType or its subtypes."@en ;
rdfs:label "Flow moving device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMovingDevice" .
### http://saref.linkeddata.es/def/bldg#FlowStorageDevice
bldg:FlowStorageDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element IfcFlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank). Its type is defined by IfcFlowStorageDeviceType or its subtypes."@en ;
rdfs:label "Flow storage device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowStorageDevice" .
### http://saref.linkeddata.es/def/bldg#FlowTerminal
bldg:FlowTerminal rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element IfcFlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment. Its type is defined by IfcFlowTerminalType or its subtypes."@en ;
rdfs:label "Flow terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTerminal" .
### http://saref.linkeddata.es/def/bldg#FlowTreatmentDevice
bldg:FlowTreatmentDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element IfcFlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system. Its type is defined by IfcFlowTreatmentDeviceType or its subtypes."@en ;
rdfs:label "Flow treatment device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTreatmentDevice" .
### http://saref.linkeddata.es/def/bldg#HeatExchanger
bldg:HeatExchanger rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment """A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers.
IfcHeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas IfcAirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air)."""@en ;
rdfs:label "Heat exchanger"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHeatExchanger" .
### http://saref.linkeddata.es/def/bldg#Humidifier
bldg:Humidifier rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A humidifier is a device that adds moisture into the air."@en ;
rdfs:label "Humidifier"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHumidifier" .
### http://saref.linkeddata.es/def/bldg#Interceptor
bldg:Interceptor rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTreatmentDevice ;
rdfs:comment "An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity."@en ;
rdfs:label "Interceptor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcInterceptor" .
### http://saref.linkeddata.es/def/bldg#Lamp
bldg:Lamp rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment "A lamp is an artificial light source such as a light bulb or tube."@en ;
rdfs:label "Lamp"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcLamp" .
### http://saref.linkeddata.es/def/bldg#MedicalDevice
bldg:MedicalDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment "A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide."@en ;
rdfs:label "Medical device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcMedicalDevice" .
### http://saref.linkeddata.es/def/bldg#Outlet
bldg:Outlet rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications.
Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture."""@en ;
rdfs:label "Outlet"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcOutlet" .
### http://saref.linkeddata.es/def/bldg#ProtectiveDevice
bldg:ProtectiveDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment """A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded.
A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection."""@en ;
rdfs:label "Protective device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDevice" .
### http://saref.linkeddata.es/def/bldg#ProtectiveDeviceTrippingUnit
bldg:ProtectiveDeviceTrippingUnit rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment "A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded."@en ;
rdfs:label "Protective device tripping unit"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDeviceTrippingUnit" .
### http://saref.linkeddata.es/def/bldg#Pump
bldg:Pump rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowMovingDevice ;
rdfs:comment "A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system."@en ;
rdfs:label "Pump"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcPump" .
### http://saref.linkeddata.es/def/bldg#SanitaryTerminal
bldg:SanitaryTerminal rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment "A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal."@en ;
rdfs:label "Sanitary terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSanitaryTerminal" .
### http://saref.linkeddata.es/def/bldg#Sensor
bldg:Sensor rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ,
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
rdfs:comment "A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument."@en ;
rdfs:label "sensor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSensor" .
### http://saref.linkeddata.es/def/bldg#ShadingDevice
bldg:ShadingDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:BuildingDevice ;
rdfs:comment "Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable."@en ;
rdfs:label "Shading device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcShadingDevice" .
### http://saref.linkeddata.es/def/bldg#SolarDevice
bldg:SolarDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A solar device converts solar radiation into other energy such as electric current or thermal energy."@en ;
rdfs:label "solar device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSolarDevice" .
### http://saref.linkeddata.es/def/bldg#SpaceHeater
bldg:SpaceHeater rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters.
IfcUnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; IfcCoil should be used for coil-based floor heating."""@en ;
rdfs:label "Space heater"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSpaceHeater" .
### http://saref.linkeddata.es/def/bldg#SwitchingDevice
bldg:SwitchingDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment """A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity.
Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports."""@en ;
rdfs:label "Switching device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSwitchingDevice" .
### http://saref.linkeddata.es/def/bldg#Tank
bldg:Tank rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowStorageDevice ;
rdfs:comment "A tank is a vessel or container in which a fluid or gas is stored for later use."@en ;
rdfs:label "Tank"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTank" .
### http://saref.linkeddata.es/def/bldg#Transformer
bldg:Transformer rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment """A transformer is an inductive stationary device that transfers electrical energy from one circuit to another.
IfcTransformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: IfcController converts arbitrary signals, IfcAudioVisualAppliance converts signals for audio or video streams, and IfcCommunicationsAppliance converts signals for data or other communications usage."""@en ;
rdfs:label "Transformer"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransformer" .
### http://saref.linkeddata.es/def/bldg#TransportElement
bldg:TransportElement rdf:type owl:Class ;
rdfs:subClassOf bldg:Device ;
rdfs:comment "A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The IfcTransportElement defines the occurrence of a transport element, that (if given), is expressed by the IfcTransportElementType. "@en ;
rdfs:label "Transport element"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransportElement" .
### http://saref.linkeddata.es/def/bldg#TubeBundle
bldg:TubeBundle rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ;
rdfs:comment "A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil."@en ;
rdfs:label "Tube bundle"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTubeBundle" .
### http://saref.linkeddata.es/def/bldg#UnitaryControlElement
bldg:UnitaryControlElement rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """A unitary control element combines a number of control components into a single product, such as a thermostat or humidistat.
A unitary control element provides a housing for an aggregation of control or electrical distribution elements that, in combination, perform a singular (unitary) purpose. Each item in the aggregation may have its own geometric representation and location."""@en ;
rdfs:label "Unitary control element"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcUnitaryControlElement" .
### http://saref.linkeddata.es/def/bldg#Valve
bldg:Valve rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment "A valve is used in a building services piping distribution system to control or modulate the flow of the fluid."@en ;
rdfs:label "Valve"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcValve" .
### http://saref.linkeddata.es/def/bldg#VibrationIsolator
bldg:VibrationIsolator rdf:type owl:Class ;
rdfs:subClassOf bldg:Device ;
rdfs:comment "A vibration isolator is a device used to minimize the effects of vibration transmissibility in a building."@en ;
rdfs:label "Vibration isolator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcVibrationIsolator" .
### https://w3id.org/saref#Device
### https://w3id.org/saref#Sensor
### Generated by the OWL API (version 4.2.6.20160910-2108) https://github.com/owlcs/owlapi