Newer
Older
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalLatentCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSensibleCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalUa ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:placementType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment """A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface.
Coils may also be used for non-airflow cases such as embedded in a floor slab."""@en ;
rdfs:label "Coil"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoil" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccoil.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_coiltypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#CommunicationAppliance
bldg:CommunicationAppliance rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """A communications appliance transmits and receives electronic or digital information as data or sound.
Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
rdfs:label "communication appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCommunicationAppliance" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifccommunicationsappliance.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_communicationsappliancetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Compressor
bldg:Compressor rdf:type owl:Class ;
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
rdfs:subClassOf bldg:FlowMovingDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:compressorSpeed ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:idealCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:idealShaftPower ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:impellerDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:partLoadRatioMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:partLoadRatioMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hasHotGasBypass ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:powerSource ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:refrigerantClass ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A compressor is a device that compresses a fluid typically used in a refrigeration circuit."@en ;
rdfs:label "Compressor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCompressor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccompressor.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_compressortypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Condenser
bldg:Condenser rdf:type owl:Class ;
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:externalSurfaceArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalRefrigerantVolume ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalSurfaceArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalWaterVolume ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalHeatTransferArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalHeatTransferCoefficient ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:refrigerantClass ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state."@en ;
rdfs:label "Condenser"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCondenser" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccondenser.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_condensertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Controller
bldg:Controller rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """A controller is a device that monitors inputs and controls outputs within a building automation system.
A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller)."""@en ;
rdfs:label "controller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcController" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifccontroller.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_controllertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#CooledBeam
bldg:CooledBeam rdf:type owl:Class ;
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:coilLength ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:coilWidth ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalCoolingCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalHeatingCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalReturnWaterTemperatureCooling ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalReturnWaterTemperatureHeating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSorroundingHumidityCooling ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSorroundingTemperatureCooling ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSorroundingTemperatureHeating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSupplyWaterTemperatureCooling ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSupplyWaterTemperatureHeating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalWaterFlowCooling ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalWaterFlowHeating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:waterPressureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:waterPressureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:finishColor ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:integratedLightingType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isFreeHanging ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:pipeConnectionEnum ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:waterFlowControlSystemType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again."@en ;
rdfs:label "Cooled beam"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCooledBeam" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccooledbeam.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_cooledbeamtypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#CoolingTower
bldg:CoolingTower rdf:type owl:Class ;
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:ambientDesignDryBulbTemperature ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:ambientDesignWetBulbTemperature ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:basinReserveVolume ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:liftElevationDifference ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalCapacity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:waterRequirement ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:capacityControl ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:circuitType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:controlStrategy ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:flowArrangement ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfCells ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:sprayType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation."@en ;
rdfs:label "Cooling tower"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoolingTower" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccoolingtower.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_coolingtowertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Damper
bldg:Damper rdf:type owl:Class ;
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
rdfs:subClassOf bldg:FlowController ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:airFlowRateMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:bladeThickness ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:closeOffRating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:faceArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:frameDepth ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:frameThickness ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:leakageFullyClosed ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalAirFlowRate ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:openPressureDrop ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:temperatureRating ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:workingPressureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:bladeAction ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:bladeEdge ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:bladeShape ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:frameType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:numberOfBlades ;
owl:allValuesFrom xsd:integer
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operation ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:orientation ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A damper typically participates in an HVAC duct distribution system and is used to control or modulate the flow of air."@en ;
rdfs:label "Damper"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDamper" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcdamper.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_dampertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#DistributionControlDevice
bldg:DistributionControlDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionDevice ;
rdfs:comment "Represents devices of a building automation control system that are used to impart control over elements of a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributioncontrolelement.htm)"@en ;
rdfs:label "Distribution control device"@en .
### http://saref.linkeddata.es/def/bldg#DistributionDevice
bldg:DistributionDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:BuildingDevice ;
rdfs:comment "Generalization of all devices that participate in a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifcdistributionelement.htm)"@en ;
rdfs:label "Distribution device"@en .
### http://saref.linkeddata.es/def/bldg#DistributionFlowDevice
bldg:DistributionFlowDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionDevice ;
rdfs:comment "Represents devices of a distribution system that facilitate the distribution of energy or matter, such as air, water or power. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributionflowelement.htm)"@en ;
rdfs:label "DistributionFlowDevice"@en .
### http://saref.linkeddata.es/def/bldg#DuctSilencer
bldg:DuctSilencer rdf:type owl:Class ;
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
rdfs:subClassOf bldg:FlowTreatmentDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:airFlowRateMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:airFlowRateMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hydraulicDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:length ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:weight ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:workingPressureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:workingPressureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hasExteriorInsulation ;
owl:allValuesFrom xsd:boolean
] ;
rdfs:comment "A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device."@en ;
rdfs:label "Duct silencer"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDuctSilencer" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcductsilencer.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_ductsilencertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ElectricAppliance
bldg:ElectricAppliance rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """An electric appliance is a device intended for consumer usage that is powered by electricity.
Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
rdfs:label "electric appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricAppliance" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricappliance.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricappliancetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ElectricFlowStorageDevice
bldg:ElectricFlowStorageDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowStorageDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalFrequency ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSupplyVoltage ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalSupplyVoltageMin ;
owl:allValuesFrom bldg:Measurement
] ;
rdfs:comment "An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released."@en ;
rdfs:label "Electric flow storage device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricFlowStorageDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricflowstoragedevice.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricflowstoragedevicetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ElectricGenerator
bldg:ElectricGenerator rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:electricGeneratorEfficiency ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:powerOutputMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:startCurrentFactor ;
owl:allValuesFrom bldg:Measurement
] ;
rdfs:comment "An electric generator is an engine that is a machine for converting mechanical energy into electrical energy."@en ;
rdfs:label "Electric generator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricGenerator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricgenerator.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricgeneratortypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ElectricMotor
bldg:ElectricMotor rdf:type owl:Class ;
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:electricMotorEfficiency ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:lockedRotorCurrent ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:powerOutputMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:startCurrentFactor ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:startingTime ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:teTime ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:frameSize ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:hasPartWinding ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:isGuarded ;
owl:allValuesFrom xsd:boolean
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:motorEnclosureType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "An electric motor is an engine that is a machine for converting electrical energy into mechanical energy."@en ;
rdfs:label "Electric motor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricMotor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricmotor.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricmotortypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#ElectricTimeControl
bldg:ElectricTimeControl rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ;
rdfs:comment "An electric time control is a device that applies control to the provision or flow of electrical energy over time."@en ;
rdfs:label "Electric time control"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricTimeControl" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectrictimecontrol.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electrictimecontroltypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#EnergyConversionDevice
bldg:EnergyConversionDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element EnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system."@en ;
rdfs:label "Energy conversion device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEnergyConversionDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcenergyconversiondevice.htm> .
### http://saref.linkeddata.es/def/bldg#Engine
bldg:Engine rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:energySource ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "An engine is a device that converts fuel into mechanical energy through combustion."@en ;
rdfs:label "Engine"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEngine" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcengine.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_enginetypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#EvaporativeCooler
bldg:EvaporativeCooler rdf:type owl:Class ;
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:heatExchangeArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:waterRequirement ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:flowArrangement ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "An evaporative cooler is a device that cools air by saturating it with water vapor."@en ;
rdfs:label "Evaporative cooler"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporativeCooler" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcevaporativecooler.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_evaporativecoolertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Evaporator
bldg:Evaporator rdf:type owl:Class ;
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:externalSurfaceArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalRefrigerantVolume ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalSurfaceArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalWaterVolume ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalHeatTransferArea ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalHeatTransferCoefficient ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:evaporationCoolant ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:evaporationMediumType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:refrigerantClass ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid."@en ;
rdfs:label "Evaporator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcevaporator.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_evaporatortypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Fan
bldg:Fan rdf:type owl:Class ;
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
rdfs:subClassOf bldg:FlowMovingDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalAirFlowRate ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalPowerRate ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalRotationSpeed ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalStaticPressure ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalTotalPressure ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationalRiterial ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:capacityControlType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:motorDriveType ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system."@en ;
rdfs:label "Fan"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFan" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcfan.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_fantypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Filter
bldg:Filter rdf:type owl:Class ;
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
rdfs:subClassOf bldg:FlowTreatmentDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:finalResistance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:fluidFlowRateMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:fluidFlowRateMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:initialResistance ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalFilterFaceVelocity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalFlowRate ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalMediaSurfaceVelocity ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalParticleGeometricMeanDiameter ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalParticleGeometricStandardDeviation ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalPressureDrop ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:operationTemperatureMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:weight ;
owl:allValuesFrom bldg:Measurement
] ;
rdfs:comment "A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases."@en ;
rdfs:label "Filter"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFilter" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcfilter.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_filtertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#FireSuppressionTerminal
bldg:FireSuppressionTerminal rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowTerminal ;
rdfs:comment """A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire.
A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire."""@en ;
rdfs:label "Fire suppression terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFireSuppressionTerminal" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/lexical/ifcfiresuppressionterminal.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/pset/pset_firesuppressionterminaltypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#FlowController
bldg:FlowController rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays."@en ;
rdfs:label "Flow controller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowController" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowcontroller.htm> .
### http://saref.linkeddata.es/def/bldg#FlowInstrument
bldg:FlowInstrument rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionControlDevice ;
rdfs:comment """A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points.
Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.)"""@en ;
rdfs:label "flow instrument"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowInstrument" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcflowinstrument.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_flowinstrumenttypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#FlowMeter
bldg:FlowMeter rdf:type owl:Class ;
rdfs:subClassOf bldg:FlowController ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:readOutType ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:remoteReading ;
owl:allValuesFrom xsd:boolean
] ;
rdfs:comment "A flow meter is a device that is used to measure the flow rate in a system."@en ;
rdfs:label "Flow meter"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMeter" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcflowmeter.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_flowmetertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#FlowMovingDevice
bldg:FlowMovingDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system."@en ;
rdfs:label "Flow moving device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMovingDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowmovingdevice.htm> .
### http://saref.linkeddata.es/def/bldg#FlowStorageDevice
bldg:FlowStorageDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank)."@en ;
rdfs:label "Flow storage device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowStorageDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowstoragedevice.htm> .
### http://saref.linkeddata.es/def/bldg#FlowTerminal
bldg:FlowTerminal rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment."@en ;
rdfs:label "Flow terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTerminal" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowterminal.htm> .
### http://saref.linkeddata.es/def/bldg#FlowTreatmentDevice
bldg:FlowTreatmentDevice rdf:type owl:Class ;
rdfs:subClassOf bldg:DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system."@en ;
rdfs:label "Flow treatment device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTreatmentDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowtreatmentdevice.htm> .
### http://saref.linkeddata.es/def/bldg#HeatExchanger
bldg:HeatExchanger rdf:type owl:Class ;
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:arrangement ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers. HeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas AirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air)."@en ;
rdfs:label "Heat exchanger"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHeatExchanger" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcheatexchanger.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_heatexchangertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Humidifier
bldg:Humidifier rdf:type owl:Class ;
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
rdfs:subClassOf bldg:EnergyConversionDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalAirFlowRate ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalMoistureGain ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:waterRequirement ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:weight ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:application ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:internalControl ;
owl:allValuesFrom xsd:string
] ;
rdfs:comment "A humidifier is a device that adds moisture into the air."@en ;
rdfs:label "Humidifier"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHumidifier" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifchumidifier.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_humidifiertypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Interceptor
bldg:Interceptor rdf:type owl:Class ;
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
rdfs:subClassOf bldg:FlowTreatmentDevice ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:coverLength ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:coverWidth ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:inletConnectionSize ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalBodyDepth ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalBodyLength ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:nominalBodyWidth ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:outletConnectionSize ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:ventilatingPipeSize ;
owl:allValuesFrom bldg:Measurement
] ;
rdfs:comment "An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity."@en ;
rdfs:label "Interceptor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcInterceptor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/lexical/ifcinterceptor.htm> ,
<http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/pset/pset_interceptortypecommon.htm> .
### http://saref.linkeddata.es/def/bldg#Lamp
bldg:Lamp rdf:type owl:Class ;
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
rdfs:subClassOf bldg:FlowTerminal ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:colorTemperature ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:contributedLuminousFlux ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:lampMaintenanceFactor ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:lightEmitterNominalPower ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:spectrumMax ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:spectrumMin ;
owl:allValuesFrom bldg:Measurement
] ,
[ rdf:type owl:Restriction ;
owl:onProperty bldg:colorAppearance ;
owl:allValuesFrom xsd:string
] ,
[ rdf:type owl:Restriction ;