Newer
Older
@prefix dc: <http://purl.org/dc/elements/1.1/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix xml: <http://www.w3.org/XML/1998/namespace> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
@prefix prov: <http://www.w3.org/ns/prov#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix vann: <http://purl.org/vocab/vann/> .
@prefix dcterms: <http://purl.org/dc/terms/> .
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
<https://w3id.org/def/saref4bldg> a owl:Ontology ;
owl:versionIRI <https://w3id.org/def/v1/saref4bldg> ;
dcterms:creator <http://purl.org/net/mpoveda> , <http://www.garcia-castro.com/foaf.rdf#me> ;
dcterms:license <http://purl.org/NET/rdflicense/cc-by4.0> ;
owl:versionInfo "1.0" ;
vann:preferredNamespaceUri "https://w3id.org/def/saref4bldg#" ;
dc:title "SAREF extension for building devices"@en ;
dc:publisher <http://www.oeg-upm.net/> ;
vann:preferredNamespacePrefix "s4bldg" ;
dc:description "This ontology extends the SAREF ontology for the building domain by defining building devices and how they are located in a building. This extension is based on the ISO 16739:2013 Industry Foundation Classes (IFC) standard for data sharing in the construction and facility management industries. The descriptions of the classes and properties extracted from IFC have been taken from the IFC documentation."@en .
#
#
# #################################################################
# #
# # Annotation properties
# #
# #################################################################
#
#
# http://purl.org/dc/terms/creator
dcterms:creator a owl:AnnotationProperty .
#
# http://purl.org/dc/terms/dateCopyrighted
dcterms:dateCopyrighted a owl:AnnotationProperty .
#
# http://purl.org/dc/terms/rightsHolder
dcterms:rightsHolder a owl:AnnotationProperty .
#
# http://purl.org/vocab/vann/preferredNamespacePrefix
vann:preferredNamespacePrefix a owl:AnnotationProperty .
#
# http://purl.org/vocab/vann/preferredNamespaceUri
vann:preferredNamespaceUri a owl:AnnotationProperty .
#
# http://www.w3.org/ns/prov#hadPrimarySource
prov:hadPrimarySource a owl:AnnotationProperty .
#
#
#
# #################################################################
# #
# # Datatypes
# #
# #################################################################
#
#
# http://www.w3.org/2001/XMLSchema#duration
xsd:duration a rdfs:Datatype .
#
#
#
# #################################################################
# #
# # Object Properties
# #
# #################################################################
#
#
# http://www.w3.org/2003/01/geo/wgs84_pos#location
<http://www.w3.org/2003/01/geo/wgs84_pos#location> a owl:ObjectProperty ;
rdfs:comment "The relation between something and the point, or other geometrical thing in space, where it is. For example, the realtionship between a radio tower and a Point with a given lat and long. Or a relationship between a park and its outline as a closed arc of points, or a road and its location as a arc (a sequence of points). Clearly in practice there will be limit to the accuracy of any such statement, but one would expect an accuracy appropriate for the size of the object and uses such as mapping ."@en ;
rdfs:isDefinedBy <http://www.w3.org/2003/01/geo/wgs84_pos#> ;
rdfs:label "location"@en .
#
# https://w3id.org/def/saref4bldg#airFlowRateMax
:airFlowRateMax a owl:ObjectProperty ;
rdfs:comment "Maximum allowable air flow rate. Usually measured in m3/s."@en ;
rdfs:label "air flow rate range max"@en .
#
# https://w3id.org/def/saref4bldg#airFlowRateMin
:airFlowRateMin a owl:ObjectProperty ;
rdfs:comment "Minimum allowable air flow rate. Usually measured in m3/s."@en ;
rdfs:label "air flow rate range min"@en .
#
# https://w3id.org/def/saref4bldg#ambientDesignDryBulbTemperature
:ambientDesignDryBulbTemperature a owl:ObjectProperty ;
rdfs:comment "Ambient design dry bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "ambient design dry bulb temperature"@en .
#
# https://w3id.org/def/saref4bldg#ambientDesignWetBulbTemperature
:ambientDesignWetBulbTemperature a owl:ObjectProperty ;
rdfs:comment "Ambient design wet bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "ambient design wet bulb temperature"@en .
#
# https://w3id.org/def/saref4bldg#apparentPowerMax
:apparentPowerMax a owl:ObjectProperty ;
rdfs:comment "Maximum apparent power/capacity in VA (volt ampere). Usually measured in Watts (W, J/s)."@en ;
rdfs:label "maximum apparent power"@en .
#
# https://w3id.org/def/saref4bldg#audioVolume
:audioVolume a owl:ObjectProperty ;
rdfs:comment "Indicates discrete audio volume levels and corresponding sound power offsets, if applicable. Missing values may be interpolated. Measured in watts."@en ;
rdfs:label "audio volume"@en .
#
# https://w3id.org/def/saref4bldg#basinReserveVolume
:basinReserveVolume a owl:ObjectProperty ;
rdfs:comment "Volume between operating and overflow levels in cooling tower basin. Usually measured in cubic metre (m3)."@en ;
rdfs:label "basin reserve volume"@en .
#
# https://w3id.org/def/saref4bldg#bladeThickness
:bladeThickness a owl:ObjectProperty ;
rdfs:comment "The thickness of the damper blade. Usually measured in millimeters (mm)."@en ;
rdfs:label "blade thickness"@en .
#
# https://w3id.org/def/saref4bldg#bodyMass
:bodyMass a owl:ObjectProperty ;
rdfs:comment "Overall body mass of the heater. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "body mass"@en .
#
# https://w3id.org/def/saref4bldg#capacityWeight
:capacityWeight a owl:ObjectProperty ;
rdfs:comment "Capacity of the transport element measured by weight. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "capacity weight"@en .
#
# https://w3id.org/def/saref4bldg#closeOffRating
:closeOffRating a owl:ObjectProperty ;
rdfs:comment "Close off rating. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "close off rating"@en .
#
# https://w3id.org/def/saref4bldg#coilLength
:coilLength a owl:ObjectProperty ;
rdfs:comment "Length of coil. Usually measured in millimeters (mm)."@en ;
rdfs:label "coil length"@en .
#
# https://w3id.org/def/saref4bldg#coilWidth
:coilWidth a owl:ObjectProperty ;
rdfs:comment "Width of coil. Usually measured in millimeters (mm"@en ;
rdfs:label "coil width"@en .
#
# https://w3id.org/def/saref4bldg#colorTemperature
:colorTemperature a owl:ObjectProperty ;
rdfs:comment "The color temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate color temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The color temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "color temperature"@en .
#
# https://w3id.org/def/saref4bldg#compressorSpeed
:compressorSpeed a owl:ObjectProperty ;
rdfs:comment "Compressor speed. Usually measured in cycles/s."@en ;
rdfs:label "compressor speed"@en .
#
# https://w3id.org/def/saref4bldg#connectionSize
:connectionSize a owl:ObjectProperty ;
rdfs:comment "The connection size of the to and from the pump. Usually measured in millimeters (mm)."@en ;
rdfs:label "connection size"@en .
#
# https://w3id.org/def/saref4bldg#contains
:contains a owl:ObjectProperty ;
owl:inverseOf :isContainedIn ;
a owl:TransitiveProperty ;
rdfs:comment "A relation between a physical space and the objects located in such space."@en ;
rdfs:label "contains"@en .
#
# https://w3id.org/def/saref4bldg#contributedLuminousFlux
:contributedLuminousFlux a owl:ObjectProperty ;
rdfs:comment "Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp. Usually measured in Lumen (lm, Candela Steradian)."@en ;
rdfs:label "contributed luminous flux"@en .
#
# https://w3id.org/def/saref4bldg#coverLength
:coverLength a owl:ObjectProperty ;
rdfs:comment "The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
rdfs:label "cover length"@en .
#
# https://w3id.org/def/saref4bldg#coverWidth
:coverWidth a owl:ObjectProperty ;
rdfs:comment "The length measured along the x-axis in the local coordinate system of the cover of the oil interceptor. Usually measured in millimeters (mm)."@en ;
rdfs:label "cover width"@en .
#
# https://w3id.org/def/saref4bldg#effectiveCapacity
:effectiveCapacity a owl:ObjectProperty ;
rdfs:comment "The total effective or actual volumetric capacity of the tank. Usually measured in cubic metre (m3).B3"@en ;
rdfs:label "effective capacity"@en .
#
# https://w3id.org/def/saref4bldg#electricGeneratorEfficiency
:electricGeneratorEfficiency a owl:ObjectProperty ;
rdfs:comment "The ratio of output capacity to intake capacity."@en ;
rdfs:label "electric generator efficiency"@en .
#
# https://w3id.org/def/saref4bldg#electricMotorEfficiency
:electricMotorEfficiency a owl:ObjectProperty ;
rdfs:comment "The ratio of output capacity to intake capacity."@en ;
rdfs:label "electric motor efficiency"@en .
#
# https://w3id.org/def/saref4bldg#externalSurfaceArea
:externalSurfaceArea a owl:ObjectProperty ;
rdfs:comment "External surface area (both primary and secondary area). Usually measured in square metre (m2)."@en ;
rdfs:label "external surface area"@en .
#
# https://w3id.org/def/saref4bldg#faceArea
:faceArea a owl:ObjectProperty ;
rdfs:comment "Face area open to the airstream. Usually measured in square metre (m2)."@en ;
rdfs:label "face area"@en .
#
# https://w3id.org/def/saref4bldg#finalResistance
:finalResistance a owl:ObjectProperty ;
rdfs:comment "Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "final resistance"@en .
#
# https://w3id.org/def/saref4bldg#firstCurvatureRadius
:firstCurvatureRadius a owl:ObjectProperty ;
rdfs:comment "FirstCurvatureRadius should be defined as the base or left side radius of curvature value. Usually measured in millimeters (mm)."@en ;
rdfs:label "first curvature radius"@en .
#
# https://w3id.org/def/saref4bldg#flowCoefficient
:flowCoefficient a owl:ObjectProperty ;
rdfs:comment "Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve."@en ;
rdfs:label "flow coefficient"@en .
#
# https://w3id.org/def/saref4bldg#flowResistanceMax
:flowResistanceMax a owl:ObjectProperty ;
rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "flow resistance range"@en .
#
# https://w3id.org/def/saref4bldg#flowResistanceMin
:flowResistanceMin a owl:ObjectProperty ;
rdfs:comment "Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "flow resistance range"@en .
#
# https://w3id.org/def/saref4bldg#fluidFlowRateMax
:fluidFlowRateMax a owl:ObjectProperty ;
rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "fluid flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#fluidFlowRateMin
:fluidFlowRateMin a owl:ObjectProperty ;
rdfs:comment "Possible range of fluid flowrate that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "fluid flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#foulingFactor
:foulingFactor a owl:ObjectProperty ;
rdfs:comment "Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
rdfs:label "fouling factor"@en .
#
# https://w3id.org/def/saref4bldg#frameDepth
:frameDepth a owl:ObjectProperty ;
rdfs:comment "The length (or depth) of the damper frame. Usually measured in millimeters (mm)."@en ;
rdfs:label "frame depth"@en .
#
# https://w3id.org/def/saref4bldg#frameThickness
:frameThickness a owl:ObjectProperty ;
rdfs:comment "The thickness of the damper frame material. Usually measured in millimeters (mm)."@en ;
rdfs:label "frame thickness"@en .
#
# https://w3id.org/def/saref4bldg#hasSpace
:hasSpace a owl:ObjectProperty ;
owl:inverseOf :isSpaceOf ;
a owl:TransitiveProperty ;
rdfs:comment "Relation between a building or a building space and the spaces it can be divided into."@en ;
rdfs:label "has space"@en .
#
# https://w3id.org/def/saref4bldg#heatExchangeArea
:heatExchangeArea a owl:ObjectProperty ;
rdfs:comment "Heat exchange area. Usually measured in square metre (m2)."@en ;
rdfs:label "heat exchange area"@en .
#
# https://w3id.org/def/saref4bldg#heatTransferSurfaceArea
:heatTransferSurfaceArea a owl:ObjectProperty ;
rdfs:comment "Total heat transfer area of the vessel. Usually measured in square metre (m2)."@en ;
rdfs:label "heat transfer surface area"@en .
#
# https://w3id.org/def/saref4bldg#height
:height a owl:ObjectProperty ;
rdfs:comment "Height of the vibration isolator before tha application of load. Usually measured in millimeters (mm)."@en ;
rdfs:label "height"@en .
#
# https://w3id.org/def/saref4bldg#horizontalSpacing
:horizontalSpacing a owl:ObjectProperty ;
rdfs:comment "Horizontal spacing between tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "horizontal spacing"@en .
#
# https://w3id.org/def/saref4bldg#hydraulicDiameter
:hydraulicDiameter a owl:ObjectProperty ;
rdfs:comment "Hydraulic diameter. Usually measured in millimeters (mm)."@en ;
rdfs:label "hydraulic diameter"@en .
#
# https://w3id.org/def/saref4bldg#idealCapacity
:idealCapacity a owl:ObjectProperty ;
rdfs:comment "Compressor capacity under ideal conditions. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "ideal capacity"@en .
#
# https://w3id.org/def/saref4bldg#idealShaftPower
:idealShaftPower a owl:ObjectProperty ;
rdfs:comment "Compressor shaft power under ideal conditions. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "ideal shaft power"@en .
#
# https://w3id.org/def/saref4bldg#imaginaryImpedanceRatio
:imaginaryImpedanceRatio a owl:ObjectProperty ;
rdfs:comment "The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
rdfs:label "imaginary impedance ratio"@en .
#
# https://w3id.org/def/saref4bldg#impellerDiameter
:impellerDiameter a owl:ObjectProperty ;
rdfs:comment "Diameter of compressor impeller - used to scale performance of geometrically similar compressors. Usually measured in millimeters (mm)."@en ;
rdfs:label "impeller diameter"@en .
#
# https://w3id.org/def/saref4bldg#inLineRowSpacing
:inLineRowSpacing a owl:ObjectProperty ;
rdfs:comment "In-line tube row spacing. Usually measured in millimeters (mm)."@en ;
rdfs:label "in line row spacing"@en .
#
# https://w3id.org/def/saref4bldg#initialResistance
:initialResistance a owl:ObjectProperty ;
rdfs:comment "Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "initial resistance"@en .
#
# https://w3id.org/def/saref4bldg#inletConnectionSize
:inletConnectionSize a owl:ObjectProperty ;
rdfs:comment "Size of the inlet connection. Usually measured in millimeters (mm)."@en ;
rdfs:label "inlet connection size"@en .
#
# https://w3id.org/def/saref4bldg#insideDiameter
:insideDiameter a owl:ObjectProperty ;
rdfs:comment "Actual inner diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "inside diameter"@en .
#
# https://w3id.org/def/saref4bldg#internalRefrigerantVolume
:internalRefrigerantVolume a owl:ObjectProperty ;
rdfs:comment "Internal volume of evaporator (refrigerant side). Usually measured in cubic metre (m3)."@en ;
rdfs:label "internal refrigerant volume"@en .
#
# https://w3id.org/def/saref4bldg#internalSurfaceArea
:internalSurfaceArea a owl:ObjectProperty ;
rdfs:comment "Internal surface area. Usually measured in square metre (m2)."@en ;
rdfs:label "internal surface area"@en .
#
# https://w3id.org/def/saref4bldg#internalWaterVolume
:internalWaterVolume a owl:ObjectProperty ;
rdfs:comment "Internal volume of evaporator (water side). Usually measured in cubic metre (m3)."@en ;
rdfs:label "internal water volume"@en .
#
# https://w3id.org/def/saref4bldg#isContainedIn
:isContainedIn a owl:ObjectProperty , owl:TransitiveProperty ;
rdfs:comment "A relation between an object and the physical space in which it is located."@en ;
rdfs:label "is contained in"@en .
#
# https://w3id.org/def/saref4bldg#isSpaceOf
:isSpaceOf a owl:ObjectProperty , owl:TransitiveProperty ;
rdfs:comment "Relation between a building space and the building or building space it belongs to."@en ;
rdfs:label "isSpaceOf"@en .
#
# https://w3id.org/def/saref4bldg#isolatorCompressibility
:isolatorCompressibility a owl:ObjectProperty ;
rdfs:comment "The compressibility of the vibration isolator."@en ;
rdfs:label "isolator compressibility"@en .
#
# https://w3id.org/def/saref4bldg#isolatorStaticDeflection
:isolatorStaticDeflection a owl:ObjectProperty ;
rdfs:comment "Static deflection of the vibration isolator. Usually measured in millimeters (mm)."@en ;
rdfs:label "isolator static deflection"@en .
#
# https://w3id.org/def/saref4bldg#lampMaintenanceFactor
:lampMaintenanceFactor a owl:ObjectProperty ;
rdfs:comment "Non recoverable losses of luminous flux of a lamp due to lamp depreciation i.e. the decreasing of light output of a luminaire due to aging and dirt."@en ;
rdfs:label "lamp maintenance factor"@en .
#
# https://w3id.org/def/saref4bldg#leakageFullyClosed
:leakageFullyClosed a owl:ObjectProperty ;
rdfs:comment "Leakage when fully closed. Usually measured in m3/s."@en ;
rdfs:label "leakage fully closed"@en .
#
# https://w3id.org/def/saref4bldg#length
:length a owl:ObjectProperty ;
rdfs:comment "The finished length of the device. Usually measured in millimeters (mm)."@en ;
rdfs:label "length"@en .
#
# https://w3id.org/def/saref4bldg#liftElevationDifference
:liftElevationDifference a owl:ObjectProperty ;
rdfs:comment "Elevation difference between cooling tower sump and the top of the tower. Usually measured in millimeters (mm)."@en ;
rdfs:label "lift elevation difference"@en .
#
# https://w3id.org/def/saref4bldg#lightEmitterNominalPower
:lightEmitterNominalPower a owl:ObjectProperty ;
rdfs:comment "Light emitter nominal power. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "light emitter nominal power"@en .
#
# https://w3id.org/def/saref4bldg#limitingTerminalSize
:limitingTerminalSize a owl:ObjectProperty ;
rdfs:comment "The maximum terminal size capacity of the device. Usually measured in square metre (m2)."@en ;
rdfs:label "limiting terminal size"@en .
#
# https://w3id.org/def/saref4bldg#lockedRotorCurrent
:lockedRotorCurrent a owl:ObjectProperty ;
rdfs:comment "Input current when a motor armature is energized but not rotating. Usually measured in Ampere (A)."@en ;
rdfs:label "locked rotor current"@en .
#
# https://w3id.org/def/saref4bldg#netPositiveSuctionHead
:netPositiveSuctionHead a owl:ObjectProperty ;
rdfs:comment "Minimum liquid pressure at the pump inlet to prevent cavitation. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "net positive suction head"@en .
#
# https://w3id.org/def/saref4bldg#nominalAirFlowRate
:nominalAirFlowRate a owl:ObjectProperty ;
rdfs:comment "Nominal rate of air flow. Usually measured in m3/s."@en ;
rdfs:label "nominal air flow rate"@en .
#
# https://w3id.org/def/saref4bldg#nominalBodyDepth
:nominalBodyDepth a owl:ObjectProperty ;
rdfs:comment "Nominal or quoted =length, measured along the z-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal body depth"@en .
#
# https://w3id.org/def/saref4bldg#nominalBodyLength
:nominalBodyLength a owl:ObjectProperty ;
rdfs:comment "Nominal or quoted length, measured along the x-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal body length"@en .
#
# https://w3id.org/def/saref4bldg#nominalBodyWidth
:nominalBodyWidth a owl:ObjectProperty ;
rdfs:comment "Nominal or quoted length, measured along the y-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal body width"@en .
#
# https://w3id.org/def/saref4bldg#nominalCapacity
:nominalCapacity a owl:ObjectProperty ;
rdfs:comment "Nominal capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal capacity"@en .
#
# https://w3id.org/def/saref4bldg#nominalCondensingTemperature
:nominalCondensingTemperature a owl:ObjectProperty ;
rdfs:comment "Chiller condensing temperature. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal condensing temperature"@en .
#
# https://w3id.org/def/saref4bldg#nominalCoolingCapacity
:nominalCoolingCapacity a owl:ObjectProperty ;
rdfs:comment "Nominal cooling capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal cooling capacity"@en .
#
# https://w3id.org/def/saref4bldg#nominalDepth
:nominalDepth a owl:ObjectProperty ;
rdfs:comment "The nominal depth of the tank. Note: Not required for a horizontal cylindrical tank. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal depth"@en .
#
# https://w3id.org/def/saref4bldg#nominalDiameter
:nominalDiameter a owl:ObjectProperty ;
rdfs:comment "Nominal diameter or width of the tubes in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal diameter"@en .
#
# https://w3id.org/def/saref4bldg#nominalEfficiency
:nominalEfficiency a owl:ObjectProperty ;
rdfs:comment "Nominal chiller efficiency under nominal conditions. "@en ;
rdfs:label "nominal efficiency"@en .
#
# https://w3id.org/def/saref4bldg#nominalEnergyConsumption
:nominalEnergyConsumption a owl:ObjectProperty ;
rdfs:comment "Nominal fuel consumption rate required to produce the total boiler heat output. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal energy consumption"@en .
#
# https://w3id.org/def/saref4bldg#nominalEvaporatingTemmperature
:nominalEvaporatingTemmperature a owl:ObjectProperty ;
rdfs:comment "Chiller evaporating temperature.Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal evaporating temmperature"@en .
#
# https://w3id.org/def/saref4bldg#nominalFilterFaceVelocity
:nominalFilterFaceVelocity a owl:ObjectProperty ;
rdfs:comment "Filter face velocity. Usually measured in m/s."@en ;
rdfs:label "nominal filter face velocity"@en .
#
# https://w3id.org/def/saref4bldg#nominalFlowRate
:nominalFlowRate a owl:ObjectProperty ;
rdfs:comment "Nominal fluid flow rate through the filter. Usually measured in m3/s."@en ;
rdfs:label "nominal flow rate"@en .
#
# https://w3id.org/def/saref4bldg#nominalFrequency
:nominalFrequency a owl:ObjectProperty ;
rdfs:comment "The nominal frequency of the supply. Usually measured in cycles/s or Hertz (Hz)."@en ;
rdfs:label "nominal frequency"@en .
#
# https://w3id.org/def/saref4bldg#nominalHeatRejectionRate
:nominalHeatRejectionRate a owl:ObjectProperty ;
rdfs:comment "Sum of the refrigeration effect and the heat equivalent of the power input to the compressor. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal heat rejection rate"@en .
#
# https://w3id.org/def/saref4bldg#nominalHeatTransferArea
:nominalHeatTransferArea a owl:ObjectProperty ;
rdfs:comment "Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2)."@en ;
rdfs:label "nominal heat transfer area"@en .
#
# https://w3id.org/def/saref4bldg#nominalHeatTransferCoefficient
:nominalHeatTransferCoefficient a owl:ObjectProperty ;
rdfs:comment "Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin."@en ;
rdfs:label "nominal heat transfer coefficient"@en .
#
# https://w3id.org/def/saref4bldg#nominalHeatingCapacity
:nominalHeatingCapacity a owl:ObjectProperty ;
rdfs:comment "Nominal heating capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal heating capacity"@en .
#
# https://w3id.org/def/saref4bldg#nominalLatentCapacity
:nominalLatentCapacity a owl:ObjectProperty ;
rdfs:comment "Nominal latent capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal latent capacity"@en .
#
# https://w3id.org/def/saref4bldg#nominalLengthOrDiameter
:nominalLengthOrDiameter a owl:ObjectProperty ;
rdfs:comment "The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal length or diameter"@en .
#
# https://w3id.org/def/saref4bldg#nominalMediaSurfaceVelocity
:nominalMediaSurfaceVelocity a owl:ObjectProperty ;
rdfs:comment "Average fluid velocity at the media surface. Usually measured in m/s."@en ;
rdfs:label "nominal media surface velocity"@en .
#
# https://w3id.org/def/saref4bldg#nominalMoistureGain
:nominalMoistureGain a owl:ObjectProperty ;
rdfs:comment "Nominal rate of water vapor added into the airstream. Usually measured in kg/s."@en ;
rdfs:label "nominal moisture gain"@en .
#
# https://w3id.org/def/saref4bldg#nominalPartLoadRatio
:nominalPartLoadRatio a owl:ObjectProperty ;
rdfs:comment "Allowable part load ratio range."@en ;
rdfs:label "nominal part load ratio"@en .
#
# https://w3id.org/def/saref4bldg#nominalParticleGeometricMeanDiameter
:nominalParticleGeometricMeanDiameter a owl:ObjectProperty ;
rdfs:comment "Particle geometric mean diameter associated with nominal efficiency. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal particle geometric mean diameter"@en .
#
# https://w3id.org/def/saref4bldg#nominalParticleGeometricStandardDeviation
:nominalParticleGeometricStandardDeviation a owl:ObjectProperty ;
rdfs:comment "Particle geometric standard deviation associated with nominal efficiency. "@en ;
rdfs:label "nominal particle geometric standard deviation"@en .
#
# https://w3id.org/def/saref4bldg#nominalPowerConsumption
:nominalPowerConsumption a owl:ObjectProperty ;
rdfs:comment "Nominal total power consumption. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal power consumption"@en .
#
# https://w3id.org/def/saref4bldg#nominalPowerRate
:nominalPowerRate a owl:ObjectProperty ;
rdfs:comment "Nominal fan power rate.Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal power rate"@en .
#
# https://w3id.org/def/saref4bldg#nominalPressureDrop
:nominalPressureDrop a owl:ObjectProperty ;
rdfs:comment "Total pressure drop across the filter. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "nominal pressure drop"@en .
#
# https://w3id.org/def/saref4bldg#nominalReturnWaterTemperatureCooling
:nominalReturnWaterTemperatureCooling a owl:ObjectProperty ;
rdfs:comment "Nominal return water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal return water temperature cooling"@en .
#
# https://w3id.org/def/saref4bldg#nominalReturnWaterTemperatureHeating
:nominalReturnWaterTemperatureHeating a owl:ObjectProperty ;
rdfs:comment "Nominal return water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal return water temperature heating"@en .
#
# https://w3id.org/def/saref4bldg#nominalRotationSpeed
:nominalRotationSpeed a owl:ObjectProperty ;
rdfs:comment "Nominal fan wheel speed. Usually measured in cycles/s."@en ;
rdfs:label "nominal rotation speed"@en .
#
# https://w3id.org/def/saref4bldg#nominalSensibleCapacity
:nominalSensibleCapacity a owl:ObjectProperty ;
rdfs:comment "Nominal sensible capacity. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "nominal sensible capacity"@en .
#
# https://w3id.org/def/saref4bldg#nominalSorroundingHumidityCooling
:nominalSorroundingHumidityCooling a owl:ObjectProperty ;
rdfs:comment "Nominal surrounding humidity (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal sorrounding humidity cooling"@en .
#
# https://w3id.org/def/saref4bldg#nominalSorroundingTemperatureCooling
:nominalSorroundingTemperatureCooling a owl:ObjectProperty ;
rdfs:comment "Nominal surrounding temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal sorrounding temperature cooling"@en .
#
# https://w3id.org/def/saref4bldg#nominalSorroundingTemperatureHeating
:nominalSorroundingTemperatureHeating a owl:ObjectProperty ;
rdfs:comment "Nominal surrounding temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal sorrounding temperature heating"@en .
#
# https://w3id.org/def/saref4bldg#nominalStaticPressure
:nominalStaticPressure a owl:ObjectProperty ;
rdfs:comment "The static pressure within the air stream that the fan must overcome to insure designed circulation of air. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "nominal static pressure"@en .
#
# https://w3id.org/def/saref4bldg#nominalSupplyVoltage
:nominalSupplyVoltage a owl:ObjectProperty ;
rdfs:comment "The nominal voltage of the supply. Usually measured in Volts (V, W/A)."@en ;
rdfs:label "nominal supply voltage"@en .
#
# https://w3id.org/def/saref4bldg#nominalSupplyVoltageMax
:nominalSupplyVoltageMax a owl:ObjectProperty ;
rdfs:comment "The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
rdfs:label "nominal supply voltage offset"@en .
#
# https://w3id.org/def/saref4bldg#nominalSupplyVoltageMin
:nominalSupplyVoltageMin a owl:ObjectProperty ;
rdfs:comment "The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V."@en ;
rdfs:label "nominal supply voltage offset"@en .
#
# https://w3id.org/def/saref4bldg#nominalSupplyWaterTemperatureCooling
:nominalSupplyWaterTemperatureCooling a owl:ObjectProperty ;
rdfs:comment "Nominal supply water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal supply water temperature cooling"@en .
#
# https://w3id.org/def/saref4bldg#nominalSupplyWaterTemperatureHeating
:nominalSupplyWaterTemperatureHeating a owl:ObjectProperty ;
rdfs:comment "Nominal supply water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "nominal supply water temperature heating"@en .
#
# https://w3id.org/def/saref4bldg#nominalTotalPressure
:nominalTotalPressure a owl:ObjectProperty ;
rdfs:comment "Nominal total pressure rise across the fan. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "nominal total pressure"@en .
#
# https://w3id.org/def/saref4bldg#nominalUa
:nominalUa a owl:ObjectProperty ;
rdfs:comment "Nominal UA value."@en ;
rdfs:label "nominal ua"@en .
#
# https://w3id.org/def/saref4bldg#nominalVolumetricCapacity
:nominalVolumetricCapacity a owl:ObjectProperty ;
rdfs:comment "The total nominal or design volumetric capacity of the tank. Usually measured in cubic metre (m3)."@en ;
rdfs:label "nominal volumetric capacity"@en .
#
# https://w3id.org/def/saref4bldg#nominalWaterFlowCooling
:nominalWaterFlowCooling a owl:ObjectProperty ;
rdfs:comment "Nominal water flow (refers to nominal cooling capacity). Usually measured in m3/s."@en ;
rdfs:label "nominal water flow cooling"@en .
#
# https://w3id.org/def/saref4bldg#nominalWaterFlowHeating
:nominalWaterFlowHeating a owl:ObjectProperty ;
rdfs:comment "Nominal water flow (refers to nominal heating capacity). Usually measured in m3/s."@en ;
rdfs:label "nominal water flow heating"@en .
#
# https://w3id.org/def/saref4bldg#nominalWidthOrDiameter
:nominalWidthOrDiameter a owl:ObjectProperty ;
rdfs:comment "The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank. Note: Not required for a vertical cylindrical tank. Usually measured in millimeters (mm)."@en ;
rdfs:label "nominal width or diameter"@en .
#
# https://w3id.org/def/saref4bldg#nomminalRotationSpeed
:nomminalRotationSpeed a owl:ObjectProperty ;
rdfs:comment "Pump rotational speed under nominal conditions. Usually measured in cycles/s."@en ;
rdfs:label "nomminal rotation speed"@en .
#
# https://w3id.org/def/saref4bldg#openPressureDrop
:openPressureDrop a owl:ObjectProperty ;
rdfs:comment "Total pressure drop across damper. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "open pressure drop"@en .
#
# https://w3id.org/def/saref4bldg#operatingWight
:operatingWight a owl:ObjectProperty ;
rdfs:comment "Operating weight of the tank including all of its contents. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "operating wight"@en .
#
# https://w3id.org/def/saref4bldg#operationTemperatureMax
:operationTemperatureMax a owl:ObjectProperty ;
rdfs:comment "Allowable operation ambient (air, fluid) temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range"@en .
#
# https://w3id.org/def/saref4bldg#operationTemperatureMin
:operationTemperatureMin a owl:ObjectProperty ;
rdfs:comment "Allowable operation ambient (air, fluid) temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "operation temperature range"@en .
#
# https://w3id.org/def/saref4bldg#operationalRiterial
:operationalRiterial a owl:ObjectProperty ;
rdfs:comment "Time of operation at maximum operational ambient air temperature. Measured in seconds (s) or days (d) or other units of time."@en ;
rdfs:label "operational riterial"@en .
#
# https://w3id.org/def/saref4bldg#outletConnectionSize
:outletConnectionSize a owl:ObjectProperty ;
rdfs:comment "Size of the outlet connection. Usually measured in millimeters (mm)."@en ;
rdfs:label "outlet connection size"@en .
#
# https://w3id.org/def/saref4bldg#outletTemperatureMax
:outletTemperatureMax a owl:ObjectProperty ;
rdfs:comment "Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "outlet temperature range"@en .
#
# https://w3id.org/def/saref4bldg#outletTemperatureMin
:outletTemperatureMin a owl:ObjectProperty ;
rdfs:comment "Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "outlet temperature range"@en .
#
# https://w3id.org/def/saref4bldg#outputCapacity
:outputCapacity a owl:ObjectProperty ;
rdfs:comment "Total nominal heat output as listed by the manufacturer. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "output capacity"@en .
#
# https://w3id.org/def/saref4bldg#outsideDiameter
:outsideDiameter a owl:ObjectProperty ;
rdfs:comment "Actual outside diameter of the tube in the tube bundle. Usually measured in millimeters (mm)."@en ;
rdfs:label "outside diameter"@en .
#
# https://w3id.org/def/saref4bldg#partLoadRatioMax
:partLoadRatioMax a owl:ObjectProperty ;
rdfs:comment "Maximum part load ratio as a fraction of nominal capacity."@en ;
rdfs:label "maximum part load ratio"@en .
#
# https://w3id.org/def/saref4bldg#partLoadRatioMin
:partLoadRatioMin a owl:ObjectProperty ;
rdfs:comment "Minimum part load ratio as a fraction of nominal capacity."@en ;
rdfs:label "minimum part load ratio"@en .
#
# https://w3id.org/def/saref4bldg#powerOutputMax
:powerOutputMax a owl:ObjectProperty ;
rdfs:comment "The maximum output power rating of the engine. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "maximum power output"@en .
#
# https://w3id.org/def/saref4bldg#pressureRating
:pressureRating a owl:ObjectProperty ;
rdfs:comment "Nominal pressure rating of the boiler as rated by the agency having jurisdiction. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "pressure rating"@en .
#
# https://w3id.org/def/saref4bldg#primaryAirFlowRateMax
:primaryAirFlowRateMax a owl:ObjectProperty ;
rdfs:comment "Maximum primary airflow that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "primary air flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#primaryAirFlowRateMin
:primaryAirFlowRateMin a owl:ObjectProperty ;
rdfs:comment "Minimum primary airflow that can be delivered. Usually measured in m3/s."@en ;
rdfs:label "primary air flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#primaryApparentPower
:primaryApparentPower a owl:ObjectProperty ;
rdfs:comment "The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "primary apparent power"@en .
#
# https://w3id.org/def/saref4bldg#primaryCurrent
:primaryCurrent a owl:ObjectProperty ;
rdfs:comment "The current that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Ampere (A)."@en ;
rdfs:label "primary current"@en .
#
# https://w3id.org/def/saref4bldg#primaryFrequency
:primaryFrequency a owl:ObjectProperty ;
rdfs:comment "The frequency that is going to be transformed and that runs into the transformer on the primary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
rdfs:label "primary frequency"@en .
#
# https://w3id.org/def/saref4bldg#primaryVoltage
:primaryVoltage a owl:ObjectProperty ;
rdfs:comment "The voltage that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Volts (V, W/A)."@en ;
rdfs:label "primary voltage"@en .
#
# https://w3id.org/def/saref4bldg#pumpFlowRateMax
:pumpFlowRateMax a owl:ObjectProperty ;
rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
rdfs:label "pump flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#pumpFlowRateMin
:pumpFlowRateMin a owl:ObjectProperty ;
rdfs:comment "Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s."@en ;
rdfs:label "pump flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#realImpedanceRatio
:realImpedanceRatio a owl:ObjectProperty ;
rdfs:comment "The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor."@en ;
rdfs:label "real impedance ratio"@en .
#
# https://w3id.org/def/saref4bldg#secondCurvatureRadius
:secondCurvatureRadius a owl:ObjectProperty ;
rdfs:comment "SecondCurvatureRadius should be defined as the top or right side radius of curvature value. Usually measured in millimeters (mm)."@en ;
rdfs:label "second curvature radius"@en .
#
# https://w3id.org/def/saref4bldg#secondaryAirFlowRateMax
:secondaryAirFlowRateMax a owl:ObjectProperty ;
rdfs:comment "Maximum secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "secondary air flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#secondaryAirFlowRateMin
:secondaryAirFlowRateMin a owl:ObjectProperty ;
rdfs:comment "Maximum secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "secondary air flow rate range"@en .
#
# https://w3id.org/def/saref4bldg#secondaryApparentPower
:secondaryApparentPower a owl:ObjectProperty ;
rdfs:comment "The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side. Usually measured in Watts (W, J/s)."@en ;
rdfs:label "secondary apparent power"@en .
#
# https://w3id.org/def/saref4bldg#secondaryCurrent
:secondaryCurrent a owl:ObjectProperty ;
rdfs:comment "The current that has been transformed and is running out of the transformer on the secondary side. Usually measured in Ampere (A)."@en ;
rdfs:label "secondary current"@en .
#
# https://w3id.org/def/saref4bldg#secondaryFrequency
:secondaryFrequency a owl:ObjectProperty ;
rdfs:comment "The frequency that has been transformed and is running out of the transformer on the secondary side. Usually measured in cycles/s or Hertz (Hz)."@en ;
rdfs:label "secondary frequency"@en .
#
# https://w3id.org/def/saref4bldg#secondaryVoltage
:secondaryVoltage a owl:ObjectProperty ;
rdfs:comment "The voltage that has been transformed and is running out of the transformer on the secondary side. Usually measured in Volts (V, W/A)."@en ;
rdfs:label "secondary voltage"@en .
#
# https://w3id.org/def/saref4bldg#shortCircuitVoltage
:shortCircuitVoltage a owl:ObjectProperty ;
rdfs:comment "A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %."@en ;
rdfs:label "short circuit voltage"@en .
#
# https://w3id.org/def/saref4bldg#size
:size a owl:ObjectProperty ;
rdfs:comment "The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.). Usually measured in millimeters (mm)."@en ;
rdfs:label "size"@en .
#
# https://w3id.org/def/saref4bldg#solarReflectance
:solarReflectance a owl:ObjectProperty ;
rdfs:comment "(Rsol): The ratio of incident solar radiation that is reflected by a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
rdfs:label "solar reflectance"@en .
#
# https://w3id.org/def/saref4bldg#solarTransmittance
:solarTransmittance a owl:ObjectProperty ;
rdfs:comment "(Tsol) The ratio of incident solar radiation that directly passes through a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1"@en ;
rdfs:label "solar transmittance"@en .
#
# https://w3id.org/def/saref4bldg#spectrumMax
:spectrumMax a owl:ObjectProperty ;
rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
rdfs:label "maximum spectrum"@en .
#
# https://w3id.org/def/saref4bldg#spectrumMin
:spectrumMin a owl:ObjectProperty ;
rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
rdfs:label "minimum spectrum"@en .
#
# https://w3id.org/def/saref4bldg#staggeredRowSpacing
:staggeredRowSpacing a owl:ObjectProperty ;
rdfs:comment "Staggered tube row spacing. Usually measured in millimeters (mm)."@en ;
rdfs:label "staggered row spacing"@en .
#
# https://w3id.org/def/saref4bldg#startCurrentFactor
:startCurrentFactor a owl:ObjectProperty ;
rdfs:comment "IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
rdfs:label "start current factor"@en .
#
# https://w3id.org/def/saref4bldg#startingTime
:startingTime a owl:ObjectProperty ;
rdfs:comment "The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals."@en ;
rdfs:label "starting time"@en .
#
# https://w3id.org/def/saref4bldg#supportedWeightMax
:supportedWeightMax a owl:ObjectProperty ;
rdfs:comment "The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "maximum supported weight"@en .
#
# https://w3id.org/def/saref4bldg#teTime
:teTime a owl:ObjectProperty ;
rdfs:comment "The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device."@en ;
rdfs:label "te time"@en .
#
# https://w3id.org/def/saref4bldg#temperatureRating
:temperatureRating a owl:ObjectProperty ;
rdfs:comment "Temperature rating. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature rating"@en .
#
# https://w3id.org/def/saref4bldg#testPressure
:testPressure a owl:ObjectProperty ;
rdfs:comment "The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "test pressure"@en .
#
# https://w3id.org/def/saref4bldg#thermalConductivity
:thermalConductivity a owl:ObjectProperty ;
rdfs:comment "Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
rdfs:label "thermal conductivity"@en .
#
# https://w3id.org/def/saref4bldg#thermalEfficiency
:thermalEfficiency a owl:ObjectProperty ;
rdfs:comment "Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input."@en ;
rdfs:label "thermal efficiency"@en .
#
# https://w3id.org/def/saref4bldg#thermalMassHeatCapacity
:thermalMassHeatCapacity a owl:ObjectProperty ;
rdfs:comment "Product of component mass and specific heat."@en ;
rdfs:label "thermal mass heat capacity"@en .
#
# https://w3id.org/def/saref4bldg#thermalTransmittance
:thermalTransmittance a owl:ObjectProperty ;
rdfs:comment "Rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin."@en ;
rdfs:label "thermal transmittance"@en .
#
# https://w3id.org/def/saref4bldg#ventilatingPipeSize
:ventilatingPipeSize a owl:ObjectProperty ;
rdfs:comment "Size of the ventilating pipe(s). Usually measured in millimeters (mm)."@en ;
rdfs:label "ventilating pipe size"@en .
#
# https://w3id.org/def/saref4bldg#verticalSpacing
:verticalSpacing a owl:ObjectProperty ;
rdfs:comment "Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm)."@en ;
rdfs:label "vertical spacing"@en .
#
# https://w3id.org/def/saref4bldg#vibrationTransmissibility
:vibrationTransmissibility a owl:ObjectProperty ;
rdfs:comment "The vibration transmissibility percentage."@en ;
rdfs:label "vibration transmissibility"@en .
#
# https://w3id.org/def/saref4bldg#visibleLightReflectance
:visibleLightReflectance a owl:ObjectProperty ;
rdfs:comment "Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit."@en ;
rdfs:label "visible light reflectance"@en .
#
# https://w3id.org/def/saref4bldg#visibleLightTransmittance
:visibleLightTransmittance a owl:ObjectProperty ;
rdfs:comment "Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit."@en ;
rdfs:label "visible light transmittance"@en .
#
# https://w3id.org/def/saref4bldg#volumen
:volumen a owl:ObjectProperty ;
rdfs:comment "Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3)."@en ;
rdfs:label "volumen"@en .
#
# https://w3id.org/def/saref4bldg#waterInletTemperatureMax
:waterInletTemperatureMax a owl:ObjectProperty ;
rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "water inlet temperature range"@en .
#
# https://w3id.org/def/saref4bldg#waterInletTemperatureMin
:waterInletTemperatureMin a owl:ObjectProperty ;
rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "water inlet temperature range"@en .
#
# https://w3id.org/def/saref4bldg#waterPressureMax
:waterPressureMax a owl:ObjectProperty ;
rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "water pressure range"@en .
#
# https://w3id.org/def/saref4bldg#waterPressureMin
:waterPressureMin a owl:ObjectProperty ;
rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "water pressure range"@en .
#
# https://w3id.org/def/saref4bldg#waterRequirement
:waterRequirement a owl:ObjectProperty ;
rdfs:comment "Make-up water requirement. Usually measured in m3/s."@en ;
rdfs:label "water requirement"@en .
#
# https://w3id.org/def/saref4bldg#waterStorageCapacity
:waterStorageCapacity a owl:ObjectProperty ;
rdfs:comment "Water storage capacity. Usually measured in cubic metre (m3)."@en ;
rdfs:label "water storage capacity"@en .
#
# https://w3id.org/def/saref4bldg#weight
:weight a owl:ObjectProperty ;
rdfs:comment "The weight of the device. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "weight"@en .
#
# https://w3id.org/def/saref4bldg#workingPressure
:workingPressure a owl:ObjectProperty ;
rdfs:comment "The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "working pressure"@en .
#
# https://w3id.org/def/saref4bldg#workingPressureMax
:workingPressureMax a owl:ObjectProperty ;
rdfs:comment "Maximum working pressure. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "maximum working pressure"@en .
#
# https://w3id.org/def/saref4bldg#workingPressureMin
:workingPressureMin a owl:ObjectProperty ;
rdfs:comment "Allowable minimum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "minimum working pressure"@en .
#
# https://w3id.org/saref#isMeasuredIn
saref:isMeasuredIn a owl:ObjectProperty ;
rdfs:comment "A relation between a measurement and the unit of measure in which the measurement value is expressed."@en ;
rdfs:isDefinedBy "https://w3id.org/saref#" ;
rdfs:label "is measured in"@en .
#
# https://w3id.org/saref#relatesToProperty
saref:relatesToProperty a owl:ObjectProperty ;
rdfs:comment "A relation between a measurement and the property such measurement is about."@en ;
rdfs:isDefinedBy "https://w3id.org/saref#" ;
rdfs:label "relates to property"@en .
#
#
#
# #################################################################
# #
# # Data properties
# #
# #################################################################
#
#
# https://w3id.org/def/saref4bldg#accessType
:accessType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole."@en ;
rdfs:label "access type"@en .
#
# https://w3id.org/def/saref4bldg#application
:application a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system."@en ;
rdfs:label "application"@en .
#
# https://w3id.org/def/saref4bldg#arrangement
:arrangement a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above."@en ;
rdfs:label "arrangement"@en .
#
# https://w3id.org/def/saref4bldg#bladeAction
:bladeAction a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Blade action."@en ;
rdfs:label "blade action"@en .
#
# https://w3id.org/def/saref4bldg#bladeEdge
:bladeEdge a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Blade edge."@en ;
rdfs:label "blade edge"@en .
#
# https://w3id.org/def/saref4bldg#bladeShape
:bladeShape a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Blade shape. Flat means triple V-groove."@en ;
rdfs:label "blade shape"@en .
#
# https://w3id.org/def/saref4bldg#capacityControl
:capacityControl a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty."@en ;
rdfs:label "capacity control"@en .
#
# https://w3id.org/def/saref4bldg#capacityControlType
:capacityControlType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper."@en ;
rdfs:label "capacity control type"@en .
#
# https://w3id.org/def/saref4bldg#capacityPeople
:capacityPeople a owl:DatatypeProperty ;
rdfs:range xsd:nonNegativeInteger ;
rdfs:comment "Capacity of the transportation element measured in numbers of person."@en ;
rdfs:label "capacity people"@en .
#
# https://w3id.org/def/saref4bldg#circuitType
:circuitType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "OpenCircuit: Exposes water directly to the cooling atmosphere. CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger. Wet: The air stream or the heat exchange surface is evaporatively cooled. Dry: No evaporation into the air stream. DryWet: A combination of a dry tower and a wet tower."@en ;
rdfs:label "circuit type"@en .
#
# https://w3id.org/def/saref4bldg#colorAppearance
:colorAppearance a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance."@en ;
rdfs:label "color appearance"@en .
#
# https://w3id.org/def/saref4bldg#colorRenderingIndex
:colorRenderingIndex a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties."@en ;
rdfs:label "color rendering index"@en .
#
# https://w3id.org/def/saref4bldg#controlStrategy
:controlStrategy a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature. WetBulbTempReset: The set-point is reset based on the wet-bulb temperature."@en ;
rdfs:label "control strategy"@en .
#
# https://w3id.org/def/saref4bldg#endShapeType
:endShapeType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5"@en ;
rdfs:label "end shape type"@en .
#
# https://w3id.org/def/saref4bldg#energySource
:energySource a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the energy source or fuel cumbusted to generate heat."@en , "The source of energy."@en ;
rdfs:label "energy source"@en .
#
# https://w3id.org/def/saref4bldg#evaporationCoolant
:evaporationCoolant a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The fluid used for the coolant in the evaporator."@en ;
rdfs:label "evaporation coolant"@en .
#
# https://w3id.org/def/saref4bldg#evaporationMediumType
:evaporationMediumType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant."@en ;
rdfs:label "evaporation medium type"@en .
#
# https://w3id.org/def/saref4bldg#failPosition
:failPosition a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Specifies the required fail-safe position of the actuator."@en ;
rdfs:label "fail position"@en .
#
# https://w3id.org/def/saref4bldg#finishColor
:finishColor a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Finish color for cooled beam."@en ;
rdfs:label "finish color"@en .
#
# https://w3id.org/def/saref4bldg#fireExit
:fireExit a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes."@en ;
rdfs:label "fire exit"@en .
#
# https://w3id.org/def/saref4bldg#flowArrangement
:flowArrangement a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: air and water flow enter in same directions."@en ;
rdfs:label "flow arrangement"@en .
#
# https://w3id.org/def/saref4bldg#frameSize
:frameSize a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard."@en ;
rdfs:label "frame size"@en .
#
# https://w3id.org/def/saref4bldg#frameType
:frameType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.)."@en ;
rdfs:label "frame type"@en .
#
# https://w3id.org/def/saref4bldg#hasDefrost
:hasDefrost a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Whether the heat exchanger has defrost function or not."@en ;
rdfs:label "has defrost"@en .
#
# https://w3id.org/def/saref4bldg#hasExteriorInsulation
:hasExteriorInsulation a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "TRUE if the silencer has exterior insulation. FALSE if it does not."@en ;
rdfs:label "has exterior insulation"@en .
#
# https://w3id.org/def/saref4bldg#hasHotGasBypass
:hasHotGasBypass a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No."@en ;
rdfs:label "has hot gas bypass"@en .
#
# https://w3id.org/def/saref4bldg#hasLock
:hasLock a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE)."@en ;
rdfs:label "has lock"@en .
#
# https://w3id.org/def/saref4bldg#hasPartWinding
:hasPartWinding a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) ."@en ;
rdfs:label "has part winding"@en .
#
# https://w3id.org/def/saref4bldg#hasTurbulator
:hasTurbulator a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "TRUE if the tube has a turbulator, FALSE if it does not."@en ;
rdfs:label "has turbulator"@en .
#
# https://w3id.org/def/saref4bldg#heatTransferDimension
:heatTransferDimension a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates how heat is transmitted according to the shape of the space heater."@en ;
rdfs:label "heat transfer dimension"@en .
#
# https://w3id.org/def/saref4bldg#heatTransferMedium
:heatTransferMedium a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the heat transfer medium if applicable."@en ;
rdfs:label "heat transfer medium"@en .
#
# https://w3id.org/def/saref4bldg#heatTransferTypeEnum
:heatTransferTypeEnum a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Type of heat transfer between the two air streams."@en ;
rdfs:label "heat transfer type enum"@en .
#
# https://w3id.org/def/saref4bldg#integratedLightingType
:integratedLightingType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Integrated lighting in cooled beam."@en ;
rdfs:label "integrated lighting type"@en .
#
# https://w3id.org/def/saref4bldg#internalControl
:internalControl a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Internal modulation control."@en ;
rdfs:label "internal control"@en .
#
# https://w3id.org/def/saref4bldg#isExternal
:isExternal a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building."@en ;
rdfs:label "is external"@en .
#
# https://w3id.org/def/saref4bldg#isFreeHanging
:isFreeHanging a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Is it free hanging type (not mounted in a false ceiling)?"@en ;
rdfs:label "is free hanging"@en .
#
# https://w3id.org/def/saref4bldg#isGuarded
:isGuarded a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE)."@en ;
rdfs:label "is guarded"@en .
#
# https://w3id.org/def/saref4bldg#isIlluminated
:isIlluminated a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is illuminated"@en .
#
# https://w3id.org/def/saref4bldg#isNeutralPrimaryTerminalAvailable
:isNeutralPrimaryTerminalAvailable a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is neutral primary terminal available"@en .
#
# https://w3id.org/def/saref4bldg#isNeutralSecondaryTerminalAvailable
:isNeutralSecondaryTerminalAvailable a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is neutral secondary terminal available"@en .
#
# https://w3id.org/def/saref4bldg#isPluggableOutlet
:isPluggableOutlet a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN)."@en ;
rdfs:label "is pluggable outlet"@en .
#
# https://w3id.org/def/saref4bldg#isWaterStorageHeater
:isWaterStorageHeater a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater."@en ;
rdfs:label "is water storage heater"@en .
#
# https://w3id.org/def/saref4bldg#lampBallastType
:lampBallastType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz)."@en ;
rdfs:label "lamp ballast type"@en .
#
# https://w3id.org/def/saref4bldg#lampCompensationType
:lampCompensationType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Identifies the form of compensation used for power factor correction and radio suppression."@en ;
rdfs:label "lamp compensation type"@en .
#
# https://w3id.org/def/saref4bldg#legend
:legend a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A text inscribed or applied to the switch as a legend to indicate purpose or function."@en ;
rdfs:label "legend"@en .
#
# https://w3id.org/def/saref4bldg#manualOverride
:manualOverride a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator."@en ;
rdfs:label "manual override"@en .
#
# https://w3id.org/def/saref4bldg#mechanicalOperated
:mechanicalOperated a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE)."@en ;
rdfs:label "mechanical operated"@en .
#
# https://w3id.org/def/saref4bldg#mediaSource
:mediaSource a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates media sources and corresponding names of ports (DistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (AudioVisualAppliance)."@en ;
rdfs:label "media source"@en .
#
# https://w3id.org/def/saref4bldg#motorDriveType
:motorDriveType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type. "@en ;
rdfs:label "motor drive type"@en .
#
# https://w3id.org/def/saref4bldg#motorEnclosureType
:motorEnclosureType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A list of the available types of motor enclosure from which that required may be selected."@en ;
rdfs:label "motor enclosure type"@en .
#
# https://w3id.org/def/saref4bldg#numberOfBlades
:numberOfBlades a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of blades."@en ;
rdfs:label "number of blades"@en .
#
# https://w3id.org/def/saref4bldg#numberOfCells
:numberOfCells a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of cells in one cooling tower unit."@en ;
rdfs:label "number of cells"@en .
#
# https://w3id.org/def/saref4bldg#numberOfCircuits
:numberOfCircuits a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of parallel fluid tube circuits."@en ;
rdfs:label "number of circuits"@en .
#
# https://w3id.org/def/saref4bldg#numberOfGangs
:numberOfGangs a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of gangs/buttons on this switch."@en ;
rdfs:label "number of gangs"@en .
#
# https://w3id.org/def/saref4bldg#numberOfPanels
:numberOfPanels a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of panels."@en ;
rdfs:label "number of panels"@en .
#
# https://w3id.org/def/saref4bldg#numberOfRows
:numberOfRows a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of tube rows in the tube bundle assembly."@en ;
rdfs:label "number of rows"@en .
#
# https://w3id.org/def/saref4bldg#numberOfSections
:numberOfSections a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of sections used."@en ;
rdfs:label "number of sections"@en .
#
# https://w3id.org/def/saref4bldg#numberOsSockets
:numberOsSockets a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence."@en ;
rdfs:label "number os sockets"@en .
#
# https://w3id.org/def/saref4bldg#operatingMode
:operatingMode a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Identifies the operating mode of the boiler."@en ;
rdfs:label "operating mode"@en .
#
# https://w3id.org/def/saref4bldg#operation
:operation a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The operational mechanism for the damper operation."@en ;
rdfs:label "operation"@en .
#
# https://w3id.org/def/saref4bldg#orientation
:orientation a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The intended orientation for the damper as specified by the manufacturer."@en ;
rdfs:label "orientation"@en .
#
# https://w3id.org/def/saref4bldg#patternType
:patternType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of pattern (or shape of a tank that may be specified."@en ;
rdfs:label "pattern type"@en .
#
# https://w3id.org/def/saref4bldg#pipeConnectionEnum
:pipeConnectionEnum a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The manner in which the pipe connection is made to the cooled beam."@en ;
rdfs:label "pipe connection enum"@en .
#
# https://w3id.org/def/saref4bldg#placementType
:placementType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates how the device is designed to be placed."@en ;
rdfs:label "placement type"@en .
#
# https://w3id.org/def/saref4bldg#powerSource
:powerSource a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Type of power driving the compressor."@en ;
rdfs:label "power source"@en .
#
# https://w3id.org/def/saref4bldg#readOutType
:readOutType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer."@en ;
rdfs:label "read out type"@en .
#
# https://w3id.org/def/saref4bldg#refrigerantClass
:refrigerantClass a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
rdfs:label "refrigerant class"@en .
#
# https://w3id.org/def/saref4bldg#remoteReading
:remoteReading a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE)."@en ;
rdfs:label "remote reading"@en .
#
# https://w3id.org/def/saref4bldg#roughness
:roughness a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A measure of the vertical deviations of the surface."@en ;
rdfs:label "roughness"@en .
#
# https://w3id.org/def/saref4bldg#secondaryCurrentType
:secondaryCurrentType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A list of the secondary current types that can result from transformer output."@en ;
rdfs:label "secondary current type"@en .
#
# https://w3id.org/def/saref4bldg#shadingDeviceType
:shadingDeviceType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Specifies the type of shading device."@en ;
rdfs:label "shading device type"@en .
#
# https://w3id.org/def/saref4bldg#sprayType
:sprayType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "SprayFilled: Water is sprayed into airflow. SplashTypeFill: water cascades over successive rows of splash bars. FilmTypeFill: water flows in a thin layer over closely spaced sheets."@en ;
rdfs:label "spray type"@en .
#
# https://w3id.org/def/saref4bldg#standard
:standard a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The designation of the standard applicable for the definition of the characteristics of the unit."@en ;
rdfs:label "standard"@en .
#
# https://w3id.org/def/saref4bldg#storageType
:storageType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the general material category intended to be stored."@en ;
rdfs:label "storage type"@en .
#
# https://w3id.org/def/saref4bldg#switchFunction
:switchFunction a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates types of switches which differs in functionality."@en ;
rdfs:label "switch function"@en .
#
# https://w3id.org/def/saref4bldg#temperatureClassification
:temperatureClassification a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam."@en ;
rdfs:label "temperature classification"@en .
#
# https://w3id.org/def/saref4bldg#transformerVectorGroup
:transformerVectorGroup a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers."@en ;
rdfs:label "transformer vector group"@en .
#
# https://w3id.org/def/saref4bldg#valveMechanism
:valveMechanism a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal."@en ;
rdfs:label "valve mechanism"@en .
#
# https://w3id.org/def/saref4bldg#valveOperation
:valveOperation a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve."@en ;
rdfs:label "valve operation"@en .
#
# https://w3id.org/def/saref4bldg#valvePattern
:valvePattern a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports."@en ;
rdfs:label "valve pattern"@en .
#
# https://w3id.org/def/saref4bldg#waterFlowControlSystemType
:waterFlowControlSystemType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Factory fitted waterflow control system."@en ;
rdfs:label "water flow control system type"@en .
#
# https://w3id.org/saref#hasTimestamp
saref:hasTimestamp a owl:DatatypeProperty , owl:FunctionalProperty ;
rdfs:range xsd:dateTime ;
rdfs:comment "A relationship stating the timestamp of an entity (e.g. a measurement)."@en ;
rdfs:isDefinedBy "https://w3id.org/saref#" ;
rdfs:label "has timestamp"@en .
#
# https://w3id.org/saref#hasValue
saref:hasValue a owl:DatatypeProperty ;
rdfs:comment "A relationship defining the value of a certain property, e.g., energy or power"@en ;
rdfs:isDefinedBy <https://w3id.org/saref#> ;
rdfs:label "has value"@en .
#
#
#
# #################################################################
# #
# # Classes
# #
# #################################################################
#
#
# https://w3id.org/def/saref4bldg#Actuator
:Actuator a owl:Class ;
rdfs:subClassOf :DistributionControlDevice , saref:Actuator , _:genid1 .
_:genid1 a owl:Restriction ;
owl:onProperty :failPosition ;
owl:allValuesFrom xsd:string .
:Actuator rdfs:subClassOf _:genid2 .
_:genid2 a owl:Restriction ;
owl:onProperty :manualOverride ;
owl:allValuesFrom xsd:boolean .
:Actuator rdfs:comment "An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion."@en ;
rdfs:label "Actuator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcActuator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcactuator.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_actuatortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#AirToAirHeatRecovery
:AirToAirHeatRecovery a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid3 .
_:genid3 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid4 .
_:genid4 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid5 .
_:genid5 a owl:Restriction ;
owl:onProperty :primaryAirFlowRateMax ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid6 .
_:genid6 a owl:Restriction ;
owl:onProperty :primaryAirFlowRateMin ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid7 .
_:genid7 a owl:Restriction ;
owl:onProperty :secondaryAirFlowRateMax ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid8 .
_:genid8 a owl:Restriction ;
owl:onProperty :secondaryAirFlowRateMin ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid9 .
_:genid9 a owl:Restriction ;
owl:onProperty :hasDefrost ;
owl:allValuesFrom xsd:boolean .
:AirToAirHeatRecovery rdfs:subClassOf _:genid10 .
_:genid10 a owl:Restriction ;
owl:onProperty :heatTransferTypeEnum ;
owl:allValuesFrom xsd:string .
:AirToAirHeatRecovery rdfs:comment "An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements."@en ;
rdfs:label "Air to air heat recovery"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAirToAirHeatRecovery" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcairtoairheatrecovery.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_airtoairheatrecoverytypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Alarm
:Alarm a owl:Class ;
rdfs:subClassOf :DistributionControlDevice ;
rdfs:comment """An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device.
Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms."""@en ;
rdfs:label "Alarm"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAlarm" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcalarm.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_alarmtypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#AudioVisualAppliance
:AudioVisualAppliance a owl:Class ;
rdfs:subClassOf :FlowTerminal , _:genid11 .
_:genid11 a owl:Restriction ;
owl:onProperty :audioVolume ;
owl:allValuesFrom saref:Measurement .
_:genid12 a owl:Restriction ;
owl:onProperty :mediaSource ;
owl:allValuesFrom xsd:string .
:AudioVisualAppliance rdfs:comment """An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video.
Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only."""@en ;
rdfs:label "Audio visual appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAudioVisualApplicance" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcaudiovisualappliance.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_audiovisualappliancetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Boiler
:Boiler a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid13 .
_:genid13 a owl:Restriction ;
owl:onProperty :heatTransferSurfaceArea ;
owl:allValuesFrom saref:Measurement .
_:genid14 a owl:Restriction ;
owl:onProperty :nominalEnergyConsumption ;
owl:allValuesFrom saref:Measurement .
_:genid15 a owl:Restriction ;
owl:onProperty :nominalPartLoadRatio ;
owl:allValuesFrom saref:Measurement .
_:genid16 a owl:Restriction ;
owl:onProperty :outletTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid17 a owl:Restriction ;
owl:onProperty :outletTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid18 a owl:Restriction ;
owl:onProperty :pressureRating ;
owl:allValuesFrom saref:Measurement .
_:genid19 a owl:Restriction ;
owl:onProperty :waterInletTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid20 a owl:Restriction ;
owl:onProperty :waterInletTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid21 a owl:Restriction ;
owl:onProperty :waterStorageCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid22 a owl:Restriction ;
owl:onProperty :energySource ;
owl:allValuesFrom xsd:string .
_:genid23 a owl:Restriction ;
owl:onProperty :isWaterStorageHeater ;
owl:allValuesFrom xsd:boolean .
_:genid24 a owl:Restriction ;
owl:onProperty :operatingMode ;
owl:allValuesFrom xsd:string .
:Boiler rdfs:comment "A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications."@en ;
rdfs:label "Boiler"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcboiler.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_boilertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Building
_:genid25 a owl:Restriction ;
owl:onProperty :hasSpace ;
owl:allValuesFrom :BuildingSpace .
:Building rdfs:comment "A building represents a structure that provides shelter for its occupants or contents and stands in one place. The building is also used to provide a basic element within the spatial structure hierarchy for the components of a building project (together with site, storey, and space)."@en ;
rdfs:label "Building"@en ;
rdfs:seeAlso <https://w3id.org/ifc/IFC4_ADD1#IfcBuilding> ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifcbuilding.htm> .
#
# https://w3id.org/def/saref4bldg#BuildingDevice
:BuildingDevice a owl:Class ;
rdfs:subClassOf :BuildingObject , saref:Device ;
rdfs:comment "A tangible object designed to accomplish a particular task in a building."@en ;
rdfs:label "Building device"@en .
#
# https://w3id.org/def/saref4bldg#BuildingObject
:BuildingObject a owl:Class ;
rdfs:subClassOf :PhysicalObject ;
rdfs:comment "An object in the building that can be controlled by devices, such as a door or a window that can be automatically opened or closed by an actuator. (Definition taken from SAREF 1.0)"@en ;
rdfs:label "Building object"@en .
#
# https://w3id.org/def/saref4bldg#BuildingSpace
_:genid26 a owl:Restriction ;
owl:onProperty :contains ;
owl:allValuesFrom :PhysicalObject .
_:genid27 a owl:Restriction ;
owl:onProperty :hasSpace ;
owl:allValuesFrom :BuildingSpace .
_:genid28 a owl:Restriction ;
owl:onProperty :isSpaceOf ;
owl:allValuesFrom _:genid29 .
_:genid31 a rdf:List ;
rdf:first :Building ;
rdf:rest _:genid30 .
_:genid30 a rdf:List ;
rdf:first :BuildingSpace ;
rdf:rest rdf:nil .
:BuildingSpace rdfs:comment "An entity used to define the physical spaces of the building. A building space contains devices or building objects."@en ;
rdfs:label "Building space"@en .
#
# https://w3id.org/def/saref4bldg#Burner
:Burner a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid32 .
_:genid32 a owl:Restriction ;
owl:onProperty :energySource ;
owl:allValuesFrom xsd:string .
:Burner rdfs:comment "A burner is a device that converts fuel into heat through combustion. It includes gas, oil, and wood burners."@en ;
rdfs:label "Burner"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBurner" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcburner.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_burnertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Chiller
:Chiller a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid33 .
_:genid33 a owl:Restriction ;
owl:onProperty :nominalCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid34 a owl:Restriction ;
owl:onProperty :nominalCondensingTemperature ;
owl:allValuesFrom saref:Measurement .
_:genid35 a owl:Restriction ;
owl:onProperty :nominalEfficiency ;
owl:allValuesFrom saref:Measurement .
_:genid36 a owl:Restriction ;
owl:onProperty :nominalEvaporatingTemmperature ;
owl:allValuesFrom saref:Measurement .
_:genid37 a owl:Restriction ;
owl:onProperty :nominalHeatRejectionRate ;
owl:allValuesFrom saref:Measurement .
_:genid38 a owl:Restriction ;
owl:onProperty :nominalPowerConsumption ;
owl:allValuesFrom saref:Measurement .
:Chiller rdfs:comment "A chiller is a device used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle to cool a fluid, typically water or a mixture of water and glycol. The chilled fluid is then used to cool and dehumidify air in a building."@en ;
rdfs:label "Chiller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcChiller" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcchiller.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_chillertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Coil
:Coil a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid39 .
_:genid39 a owl:Restriction ;
owl:onProperty :airFlowRateMax ;
owl:allValuesFrom saref:Measurement .
_:genid40 a owl:Restriction ;
owl:onProperty :airFlowRateMin ;
owl:allValuesFrom saref:Measurement .
_:genid41 a owl:Restriction ;
owl:onProperty :nominalLatentCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid42 a owl:Restriction ;
owl:onProperty :nominalSensibleCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid43 a owl:Restriction ;
owl:onProperty :nominalUa ;
owl:allValuesFrom saref:Measurement .
_:genid44 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid45 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid46 a owl:Restriction ;
owl:onProperty :placementType ;
owl:allValuesFrom xsd:string .
:Coil rdfs:comment """A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface.
Coils may also be used for non-airflow cases such as embedded in a floor slab."""@en ;
rdfs:label "Coil"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoil" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccoil.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_coiltypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#CommunicationAppliance
:CommunicationAppliance a owl:Class ;
rdfs:subClassOf :FlowTerminal ;
rdfs:comment """A communications appliance transmits and receives electronic or digital information as data or sound.
Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
rdfs:label "Communication appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCommunicationAppliance" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifccommunicationsappliance.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_communicationsappliancetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Compressor
:Compressor a owl:Class ;
rdfs:subClassOf :FlowMovingDevice , _:genid47 .
_:genid47 a owl:Restriction ;
owl:onProperty :compressorSpeed ;
owl:allValuesFrom saref:Measurement .
_:genid48 a owl:Restriction ;
owl:onProperty :idealCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid49 a owl:Restriction ;
owl:onProperty :idealShaftPower ;
owl:allValuesFrom saref:Measurement .
_:genid50 a owl:Restriction ;
owl:onProperty :impellerDiameter ;
owl:allValuesFrom saref:Measurement .
_:genid51 a owl:Restriction ;
owl:onProperty :nominalCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid52 a owl:Restriction ;
owl:onProperty :partLoadRatioMax ;
owl:allValuesFrom saref:Measurement .
_:genid53 a owl:Restriction ;
owl:onProperty :partLoadRatioMin ;
owl:allValuesFrom saref:Measurement .
_:genid54 a owl:Restriction ;
owl:onProperty :hasHotGasBypass ;
owl:allValuesFrom xsd:boolean .
_:genid55 a owl:Restriction ;
owl:onProperty :powerSource ;
owl:allValuesFrom xsd:string .
_:genid56 a owl:Restriction ;
owl:onProperty :refrigerantClass ;
owl:allValuesFrom xsd:string .
:Compressor rdfs:comment "A compressor is a device that compresses a fluid typically used in a refrigeration circuit."@en ;
rdfs:label "Compressor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCompressor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccompressor.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_compressortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Condenser
:Condenser a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid57 .
_:genid57 a owl:Restriction ;
owl:onProperty :externalSurfaceArea ;
owl:allValuesFrom saref:Measurement .
_:genid58 a owl:Restriction ;
owl:onProperty :internalRefrigerantVolume ;
owl:allValuesFrom saref:Measurement .
_:genid59 a owl:Restriction ;
owl:onProperty :internalSurfaceArea ;
owl:allValuesFrom saref:Measurement .
_:genid60 a owl:Restriction ;
owl:onProperty :internalWaterVolume ;
owl:allValuesFrom saref:Measurement .
_:genid61 a owl:Restriction ;
owl:onProperty :nominalHeatTransferArea ;
owl:allValuesFrom saref:Measurement .
_:genid62 a owl:Restriction ;
owl:onProperty :nominalHeatTransferCoefficient ;
owl:allValuesFrom saref:Measurement .
_:genid63 a owl:Restriction ;
owl:onProperty :refrigerantClass ;
owl:allValuesFrom xsd:string .
:Condenser rdfs:comment "A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state."@en ;
rdfs:label "Condenser"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCondenser" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccondenser.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_condensertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Controller
:Controller a owl:Class ;
rdfs:subClassOf :DistributionControlDevice ;
rdfs:comment """A controller is a device that monitors inputs and controls outputs within a building automation system.
A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller)."""@en ;
rdfs:label "Controller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcController" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifccontroller.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_controllertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#CooledBeam
:CooledBeam a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid64 .
_:genid64 a owl:Restriction ;
owl:onProperty :coilLength ;
owl:allValuesFrom saref:Measurement .
_:genid65 a owl:Restriction ;
owl:onProperty :coilWidth ;
owl:allValuesFrom saref:Measurement .
_:genid66 a owl:Restriction ;
owl:onProperty :nominalCoolingCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid67 a owl:Restriction ;
owl:onProperty :nominalHeatingCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid68 a owl:Restriction ;
owl:onProperty :nominalReturnWaterTemperatureCooling ;
owl:allValuesFrom saref:Measurement .
_:genid69 a owl:Restriction ;
owl:onProperty :nominalReturnWaterTemperatureHeating ;
owl:allValuesFrom saref:Measurement .
_:genid70 a owl:Restriction ;
owl:onProperty :nominalSorroundingHumidityCooling ;
owl:allValuesFrom saref:Measurement .
_:genid71 a owl:Restriction ;
owl:onProperty :nominalSorroundingTemperatureCooling ;
owl:allValuesFrom saref:Measurement .
_:genid72 a owl:Restriction ;
owl:onProperty :nominalSorroundingTemperatureHeating ;
owl:allValuesFrom saref:Measurement .
_:genid73 a owl:Restriction ;
owl:onProperty :nominalSupplyWaterTemperatureCooling ;
owl:allValuesFrom saref:Measurement .
_:genid74 a owl:Restriction ;
owl:onProperty :nominalSupplyWaterTemperatureHeating ;
owl:allValuesFrom saref:Measurement .
_:genid75 a owl:Restriction ;
owl:onProperty :nominalWaterFlowCooling ;
owl:allValuesFrom saref:Measurement .
_:genid76 a owl:Restriction ;
owl:onProperty :nominalWaterFlowHeating ;
owl:allValuesFrom saref:Measurement .
_:genid77 a owl:Restriction ;
owl:onProperty :waterPressureMax ;
owl:allValuesFrom saref:Measurement .
_:genid78 a owl:Restriction ;
owl:onProperty :waterPressureMin ;
owl:allValuesFrom saref:Measurement .
_:genid79 a owl:Restriction ;
owl:onProperty :finishColor ;
owl:allValuesFrom xsd:string .
_:genid80 a owl:Restriction ;
owl:onProperty :integratedLightingType ;
owl:allValuesFrom xsd:string .
_:genid81 a owl:Restriction ;
owl:onProperty :isFreeHanging ;
owl:allValuesFrom xsd:boolean .
_:genid82 a owl:Restriction ;
owl:onProperty :pipeConnectionEnum ;
owl:allValuesFrom xsd:string .
_:genid83 a owl:Restriction ;
owl:onProperty :waterFlowControlSystemType ;
owl:allValuesFrom xsd:string .
:CooledBeam rdfs:comment "A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again."@en ;
rdfs:label "Cooled beam"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCooledBeam" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccooledbeam.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_cooledbeamtypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#CoolingTower
:CoolingTower a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid84 .
_:genid84 a owl:Restriction ;
owl:onProperty :ambientDesignDryBulbTemperature ;
owl:allValuesFrom saref:Measurement .
_:genid85 a owl:Restriction ;
owl:onProperty :ambientDesignWetBulbTemperature ;
owl:allValuesFrom saref:Measurement .
_:genid86 a owl:Restriction ;
owl:onProperty :basinReserveVolume ;
owl:allValuesFrom saref:Measurement .
_:genid87 a owl:Restriction ;
owl:onProperty :liftElevationDifference ;
owl:allValuesFrom saref:Measurement .
_:genid88 a owl:Restriction ;
owl:onProperty :nominalCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid89 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid90 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid91 a owl:Restriction ;
owl:onProperty :waterRequirement ;
owl:allValuesFrom saref:Measurement .
_:genid92 a owl:Restriction ;
owl:onProperty :capacityControl ;
owl:allValuesFrom xsd:string .
_:genid93 a owl:Restriction ;
owl:onProperty :circuitType ;
owl:allValuesFrom xsd:string .
_:genid94 a owl:Restriction ;
owl:onProperty :controlStrategy ;
owl:allValuesFrom xsd:string .
_:genid95 a owl:Restriction ;
owl:onProperty :flowArrangement ;
owl:allValuesFrom xsd:string .
_:genid96 a owl:Restriction ;
owl:onProperty :numberOfCells ;
owl:allValuesFrom xsd:integer .
_:genid97 a owl:Restriction ;
owl:onProperty :sprayType ;
owl:allValuesFrom xsd:string .
:CoolingTower rdfs:comment "A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation."@en ;
rdfs:label "Cooling tower"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcCoolingTower" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifccoolingtower.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_coolingtowertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Damper
:Damper a owl:Class ;
rdfs:subClassOf :FlowController , _:genid98 .
_:genid98 a owl:Restriction ;
owl:onProperty :airFlowRateMax ;
owl:allValuesFrom saref:Measurement .
_:genid99 a owl:Restriction ;
owl:onProperty :bladeThickness ;
owl:allValuesFrom saref:Measurement .
_:genid100 a owl:Restriction ;
owl:onProperty :closeOffRating ;
owl:allValuesFrom saref:Measurement .
_:genid101 a owl:Restriction ;
owl:onProperty :faceArea ;
owl:allValuesFrom saref:Measurement .
_:genid102 a owl:Restriction ;
owl:onProperty :frameDepth ;
owl:allValuesFrom saref:Measurement .
_:genid103 a owl:Restriction ;
owl:onProperty :frameThickness ;
owl:allValuesFrom saref:Measurement .
_:genid104 a owl:Restriction ;
owl:onProperty :leakageFullyClosed ;
owl:allValuesFrom saref:Measurement .
_:genid105 a owl:Restriction ;
owl:onProperty :nominalAirFlowRate ;
owl:allValuesFrom saref:Measurement .
_:genid106 a owl:Restriction ;
owl:onProperty :openPressureDrop ;
owl:allValuesFrom saref:Measurement .
_:genid107 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid108 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid109 a owl:Restriction ;
owl:onProperty :temperatureRating ;
owl:allValuesFrom saref:Measurement .
_:genid110 a owl:Restriction ;
owl:onProperty :workingPressureMax ;
owl:allValuesFrom saref:Measurement .
_:genid111 a owl:Restriction ;
owl:onProperty :bladeAction ;
owl:allValuesFrom xsd:string .
_:genid112 a owl:Restriction ;
owl:onProperty :bladeEdge ;
owl:allValuesFrom xsd:string .
_:genid113 a owl:Restriction ;
owl:onProperty :bladeShape ;
owl:allValuesFrom xsd:string .
_:genid114 a owl:Restriction ;
owl:onProperty :frameType ;
owl:allValuesFrom xsd:string .
_:genid115 a owl:Restriction ;
owl:onProperty :numberOfBlades ;
owl:allValuesFrom xsd:integer .
_:genid116 a owl:Restriction ;
owl:onProperty :operation ;
owl:allValuesFrom xsd:string .
_:genid117 a owl:Restriction ;
owl:onProperty :orientation ;
owl:allValuesFrom xsd:string .
:Damper rdfs:comment "A damper typically participates in an HVAC duct distribution system and is used to control or modulate the flow of air."@en ;
rdfs:label "Damper"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDamper" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcdamper.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_dampertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#DistributionControlDevice
:DistributionControlDevice a owl:Class ;
rdfs:subClassOf :DistributionDevice ;
rdfs:comment "Represents devices of a building automation control system that are used to impart control over elements of a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributioncontrolelement.htm)"@en ;
rdfs:label "Distribution control device"@en .
#
# https://w3id.org/def/saref4bldg#DistributionDevice
:DistributionDevice a owl:Class ;
rdfs:subClassOf :BuildingDevice ;
rdfs:comment "Generalization of all devices that participate in a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifcdistributionelement.htm)"@en ;
rdfs:label "Distribution device"@en .
#
# https://w3id.org/def/saref4bldg#DistributionFlowDevice
:DistributionFlowDevice a owl:Class ;
rdfs:subClassOf :DistributionDevice ;
rdfs:comment "Represents devices of a distribution system that facilitate the distribution of energy or matter, such as air, water or power. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributionflowelement.htm)"@en ;
rdfs:label "DistributionFlowDevice"@en .
#
# https://w3id.org/def/saref4bldg#DuctSilencer
:DuctSilencer a owl:Class ;
rdfs:subClassOf :FlowTreatmentDevice , _:genid118 .
_:genid118 a owl:Restriction ;
owl:onProperty :airFlowRateMax ;
owl:allValuesFrom saref:Measurement .
_:genid119 a owl:Restriction ;
owl:onProperty :airFlowRateMin ;
owl:allValuesFrom saref:Measurement .
_:genid120 a owl:Restriction ;
owl:onProperty :hydraulicDiameter ;
owl:allValuesFrom saref:Measurement .
_:genid121 a owl:Restriction ;
owl:onProperty :length ;
owl:allValuesFrom saref:Measurement .
_:genid122 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid123 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid124 a owl:Restriction ;
owl:onProperty :weight ;
owl:allValuesFrom saref:Measurement .
_:genid125 a owl:Restriction ;
owl:onProperty :workingPressureMax ;
owl:allValuesFrom saref:Measurement .
_:genid126 a owl:Restriction ;
owl:onProperty :workingPressureMin ;
owl:allValuesFrom saref:Measurement .
_:genid127 a owl:Restriction ;
owl:onProperty :hasExteriorInsulation ;
owl:allValuesFrom xsd:boolean .
:DuctSilencer rdfs:comment "A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device."@en ;
rdfs:label "Duct silencer"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcDuctSilencer" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcductsilencer.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_ductsilencertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ElectricAppliance
:ElectricAppliance a owl:Class ;
rdfs:subClassOf :FlowTerminal ;
rdfs:comment """An electric appliance is a device intended for consumer usage that is powered by electricity.
Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source."""@en ;
rdfs:label "Electric appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricAppliance" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricappliance.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricappliancetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ElectricFlowStorageDevice
:ElectricFlowStorageDevice a owl:Class ;
rdfs:subClassOf :FlowStorageDevice , _:genid128 .
_:genid128 a owl:Restriction ;
owl:onProperty :nominalFrequency ;
owl:allValuesFrom saref:Measurement .
_:genid129 a owl:Restriction ;
owl:onProperty :nominalSupplyVoltage ;
owl:allValuesFrom saref:Measurement .
_:genid130 a owl:Restriction ;
owl:onProperty :nominalSupplyVoltageMin ;
owl:allValuesFrom saref:Measurement .
:ElectricFlowStorageDevice rdfs:comment "An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released."@en ;
rdfs:label "Electric flow storage device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricFlowStorageDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricflowstoragedevice.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricflowstoragedevicetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ElectricGenerator
:ElectricGenerator a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid131 .
_:genid131 a owl:Restriction ;
owl:onProperty :electricGeneratorEfficiency ;
owl:allValuesFrom saref:Measurement .
_:genid132 a owl:Restriction ;
owl:onProperty :powerOutputMax ;
owl:allValuesFrom saref:Measurement .
_:genid133 a owl:Restriction ;
owl:onProperty :startCurrentFactor ;
owl:allValuesFrom saref:Measurement .
:ElectricGenerator rdfs:comment "An electric generator is an engine that is a machine for converting mechanical energy into electrical energy."@en ;
rdfs:label "Electric generator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricGenerator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricgenerator.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricgeneratortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ElectricMotor
:ElectricMotor a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid134 .
_:genid134 a owl:Restriction ;
owl:onProperty :electricMotorEfficiency ;
owl:allValuesFrom saref:Measurement .
_:genid135 a owl:Restriction ;
owl:onProperty :lockedRotorCurrent ;
owl:allValuesFrom saref:Measurement .
_:genid136 a owl:Restriction ;
owl:onProperty :powerOutputMax ;
owl:allValuesFrom saref:Measurement .
_:genid137 a owl:Restriction ;
owl:onProperty :startCurrentFactor ;
owl:allValuesFrom saref:Measurement .
_:genid138 a owl:Restriction ;
owl:onProperty :startingTime ;
owl:allValuesFrom saref:Measurement .
_:genid139 a owl:Restriction ;
owl:onProperty :teTime ;
owl:allValuesFrom saref:Measurement .
_:genid140 a owl:Restriction ;
owl:onProperty :frameSize ;
owl:allValuesFrom xsd:string .
_:genid141 a owl:Restriction ;
owl:onProperty :hasPartWinding ;
owl:allValuesFrom xsd:boolean .
_:genid142 a owl:Restriction ;
owl:onProperty :isGuarded ;
owl:allValuesFrom xsd:boolean .
_:genid143 a owl:Restriction ;
owl:onProperty :motorEnclosureType ;
owl:allValuesFrom xsd:string .
:ElectricMotor rdfs:comment "An electric motor is an engine that is a machine for converting electrical energy into mechanical energy."@en ;
rdfs:label "Electric motor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricMotor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectricmotor.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electricmotortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ElectricTimeControl
:ElectricTimeControl a owl:Class ;
rdfs:subClassOf :FlowController ;
rdfs:comment "An electric time control is a device that applies control to the provision or flow of electrical energy over time."@en ;
rdfs:label "Electric time control"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcElectricTimeControl" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcelectrictimecontrol.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_electrictimecontroltypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#EnergyConversionDevice
:EnergyConversionDevice a owl:Class ;
rdfs:subClassOf :DistributionFlowDevice ;
rdfs:comment "The distribution flow element EnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system."@en ;
rdfs:label "Energy conversion device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEnergyConversionDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcenergyconversiondevice.htm> .
#
# https://w3id.org/def/saref4bldg#Engine
:Engine a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid144 .
_:genid144 a owl:Restriction ;
owl:onProperty :energySource ;
owl:allValuesFrom xsd:string .
:Engine rdfs:comment "An engine is a device that converts fuel into mechanical energy through combustion."@en ;
rdfs:label "Engine"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEngine" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcengine.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_enginetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#EvaporativeCooler
:EvaporativeCooler a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid145 .
_:genid145 a owl:Restriction ;
owl:onProperty :heatExchangeArea ;
owl:allValuesFrom saref:Measurement .
_:genid146 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid147 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid148 a owl:Restriction ;
owl:onProperty :waterRequirement ;
owl:allValuesFrom saref:Measurement .
_:genid149 a owl:Restriction ;
owl:onProperty :flowArrangement ;
owl:allValuesFrom xsd:string .
:EvaporativeCooler rdfs:comment "An evaporative cooler is a device that cools air by saturating it with water vapor."@en ;
rdfs:label "Evaporative cooler"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporativeCooler" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcevaporativecooler.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_evaporativecoolertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Evaporator
:Evaporator a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid150 .
_:genid150 a owl:Restriction ;
owl:onProperty :externalSurfaceArea ;
owl:allValuesFrom saref:Measurement .
_:genid151 a owl:Restriction ;
owl:onProperty :internalRefrigerantVolume ;
owl:allValuesFrom saref:Measurement .
_:genid152 a owl:Restriction ;
owl:onProperty :internalSurfaceArea ;
owl:allValuesFrom saref:Measurement .
_:genid153 a owl:Restriction ;
owl:onProperty :internalWaterVolume ;
owl:allValuesFrom saref:Measurement .
_:genid154 a owl:Restriction ;
owl:onProperty :nominalHeatTransferArea ;
owl:allValuesFrom saref:Measurement .
_:genid155 a owl:Restriction ;
owl:onProperty :nominalHeatTransferCoefficient ;
owl:allValuesFrom saref:Measurement .
_:genid156 a owl:Restriction ;
owl:onProperty :evaporationCoolant ;
owl:allValuesFrom xsd:string .
_:genid157 a owl:Restriction ;
owl:onProperty :evaporationMediumType ;
owl:allValuesFrom xsd:string .
_:genid158 a owl:Restriction ;
owl:onProperty :refrigerantClass ;
owl:allValuesFrom xsd:string .
:Evaporator rdfs:comment "An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid."@en ;
rdfs:label "Evaporator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcEvaporator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcevaporator.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_evaporatortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Fan
:Fan a owl:Class ;
rdfs:subClassOf :FlowMovingDevice , _:genid159 .
_:genid159 a owl:Restriction ;
owl:onProperty :nominalAirFlowRate ;
owl:allValuesFrom saref:Measurement .
_:genid160 a owl:Restriction ;
owl:onProperty :nominalPowerRate ;
owl:allValuesFrom saref:Measurement .
_:genid161 a owl:Restriction ;
owl:onProperty :nominalRotationSpeed ;
owl:allValuesFrom saref:Measurement .
_:genid162 a owl:Restriction ;
owl:onProperty :nominalStaticPressure ;
owl:allValuesFrom saref:Measurement .
_:genid163 a owl:Restriction ;
owl:onProperty :nominalTotalPressure ;
owl:allValuesFrom saref:Measurement .
_:genid164 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid165 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid166 a owl:Restriction ;
owl:onProperty :operationalRiterial ;
owl:allValuesFrom saref:Measurement .
_:genid167 a owl:Restriction ;
owl:onProperty :capacityControlType ;
owl:allValuesFrom xsd:string .
_:genid168 a owl:Restriction ;
owl:onProperty :motorDriveType ;
owl:allValuesFrom xsd:string .
:Fan rdfs:comment "A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system."@en ;
rdfs:label "Fan"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFan" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcfan.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_fantypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Filter
:Filter a owl:Class ;
rdfs:subClassOf :FlowTreatmentDevice , _:genid169 .
_:genid169 a owl:Restriction ;
owl:onProperty :finalResistance ;
owl:allValuesFrom saref:Measurement .
_:genid170 a owl:Restriction ;
owl:onProperty :fluidFlowRateMax ;
owl:allValuesFrom saref:Measurement .
_:genid171 a owl:Restriction ;
owl:onProperty :fluidFlowRateMin ;
owl:allValuesFrom saref:Measurement .
_:genid172 a owl:Restriction ;
owl:onProperty :initialResistance ;
owl:allValuesFrom saref:Measurement .
_:genid173 a owl:Restriction ;
owl:onProperty :nominalFilterFaceVelocity ;
owl:allValuesFrom saref:Measurement .
_:genid174 a owl:Restriction ;
owl:onProperty :nominalFlowRate ;
owl:allValuesFrom saref:Measurement .
_:genid175 a owl:Restriction ;
owl:onProperty :nominalMediaSurfaceVelocity ;
owl:allValuesFrom saref:Measurement .
_:genid176 a owl:Restriction ;
owl:onProperty :nominalParticleGeometricMeanDiameter ;
owl:allValuesFrom saref:Measurement .
_:genid177 a owl:Restriction ;
owl:onProperty :nominalParticleGeometricStandardDeviation ;
owl:allValuesFrom saref:Measurement .
_:genid178 a owl:Restriction ;
owl:onProperty :nominalPressureDrop ;
owl:allValuesFrom saref:Measurement .
_:genid179 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid180 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid181 a owl:Restriction ;
owl:onProperty :weight ;
owl:allValuesFrom saref:Measurement .
:Filter rdfs:comment "A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases."@en ;
rdfs:label "Filter"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFilter" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcfilter.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_filtertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#FireSuppressionTerminal
:FireSuppressionTerminal a owl:Class ;
rdfs:subClassOf :FlowTerminal ;
rdfs:comment """A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire.
A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire."""@en ;
rdfs:label "Fire suppression terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFireSuppressionTerminal" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/lexical/ifcfiresuppressionterminal.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/pset/pset_firesuppressionterminaltypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#FlowController
:FlowController a owl:Class ;
rdfs:subClassOf :DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays."@en ;
rdfs:label "Flow controller"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowController" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowcontroller.htm> .
#
# https://w3id.org/def/saref4bldg#FlowInstrument
:FlowInstrument a owl:Class ;
rdfs:subClassOf :DistributionControlDevice ;
rdfs:comment """A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points.
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.)"""@en ;
rdfs:label "Flow instrument"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowInstrument" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcflowinstrument.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_flowinstrumenttypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#FlowMeter
:FlowMeter a owl:Class ;
rdfs:subClassOf :FlowController , _:genid182 .
_:genid182 a owl:Restriction ;
owl:onProperty :readOutType ;
owl:allValuesFrom xsd:string .
:FlowMeter rdfs:subClassOf _:genid183 .
_:genid183 a owl:Restriction ;
owl:onProperty :remoteReading ;
owl:allValuesFrom xsd:boolean .
:FlowMeter rdfs:comment "A flow meter is a device that is used to measure the flow rate in a system."@en ;
rdfs:label "Flow meter"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMeter" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcflowmeter.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_flowmetertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#FlowMovingDevice
:FlowMovingDevice a owl:Class ;
rdfs:subClassOf :DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system."@en ;
rdfs:label "Flow moving device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowMovingDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowmovingdevice.htm> .
#
# https://w3id.org/def/saref4bldg#FlowStorageDevice
:FlowStorageDevice a owl:Class ;
rdfs:subClassOf :DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank)."@en ;
rdfs:label "Flow storage device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowStorageDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowstoragedevice.htm> .
#
# https://w3id.org/def/saref4bldg#FlowTerminal
:FlowTerminal a owl:Class ;
rdfs:subClassOf :DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment."@en ;
rdfs:label "Flow terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTerminal" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowterminal.htm> .
#
# https://w3id.org/def/saref4bldg#FlowTreatmentDevice
:FlowTreatmentDevice a owl:Class ;
rdfs:subClassOf :DistributionFlowDevice ;
rdfs:comment "The distribution flow element FlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system."@en ;
rdfs:label "Flow treatment device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcFlowTreatmentDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcflowtreatmentdevice.htm> .
#
# https://w3id.org/def/saref4bldg#HeatExchanger
:HeatExchanger a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid184 .
_:genid184 a owl:Restriction ;
owl:onProperty :arrangement ;
owl:allValuesFrom xsd:string .
:HeatExchanger rdfs:comment "A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers. HeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas AirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air)."@en ;
rdfs:label "Heat exchanger"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHeatExchanger" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcheatexchanger.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_heatexchangertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Humidifier
:Humidifier a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid185 .
_:genid185 a owl:Restriction ;
owl:onProperty :nominalAirFlowRate ;
owl:allValuesFrom saref:Measurement .
_:genid186 a owl:Restriction ;
owl:onProperty :nominalMoistureGain ;
owl:allValuesFrom saref:Measurement .
_:genid187 a owl:Restriction ;
owl:onProperty :waterRequirement ;
owl:allValuesFrom saref:Measurement .
_:genid188 a owl:Restriction ;
owl:onProperty :weight ;
owl:allValuesFrom saref:Measurement .
_:genid189 a owl:Restriction ;
owl:onProperty :application ;
owl:allValuesFrom xsd:string .
_:genid190 a owl:Restriction ;
owl:onProperty :internalControl ;
owl:allValuesFrom xsd:string .
:Humidifier rdfs:comment "A humidifier is a device that adds moisture into the air."@en ;
rdfs:label "Humidifier"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcHumidifier" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifchumidifier.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_humidifiertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Interceptor
:Interceptor a owl:Class ;
rdfs:subClassOf :FlowTreatmentDevice , _:genid191 .
_:genid191 a owl:Restriction ;
owl:onProperty :coverLength ;
owl:allValuesFrom saref:Measurement .
_:genid192 a owl:Restriction ;
owl:onProperty :coverWidth ;
owl:allValuesFrom saref:Measurement .
_:genid193 a owl:Restriction ;
owl:onProperty :inletConnectionSize ;
owl:allValuesFrom saref:Measurement .
_:genid194 a owl:Restriction ;
owl:onProperty :nominalBodyDepth ;
owl:allValuesFrom saref:Measurement .
_:genid195 a owl:Restriction ;
owl:onProperty :nominalBodyLength ;
owl:allValuesFrom saref:Measurement .
_:genid196 a owl:Restriction ;
owl:onProperty :nominalBodyWidth ;
owl:allValuesFrom saref:Measurement .
_:genid197 a owl:Restriction ;
owl:onProperty :outletConnectionSize ;
owl:allValuesFrom saref:Measurement .
_:genid198 a owl:Restriction ;
owl:onProperty :ventilatingPipeSize ;
owl:allValuesFrom saref:Measurement .
:Interceptor rdfs:comment "An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity."@en ;
rdfs:label "Interceptor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcInterceptor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/lexical/ifcinterceptor.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/pset/pset_interceptortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Lamp
:Lamp a owl:Class ;
rdfs:subClassOf :FlowTerminal , _:genid199 .
_:genid199 a owl:Restriction ;
owl:onProperty :colorTemperature ;
owl:allValuesFrom saref:Measurement .
_:genid200 a owl:Restriction ;
owl:onProperty :contributedLuminousFlux ;
owl:allValuesFrom saref:Measurement .
_:genid201 a owl:Restriction ;
owl:onProperty :lampMaintenanceFactor ;
owl:allValuesFrom saref:Measurement .
_:genid202 a owl:Restriction ;
owl:onProperty :lightEmitterNominalPower ;
owl:allValuesFrom saref:Measurement .
_:genid203 a owl:Restriction ;
owl:onProperty :spectrumMax ;
owl:allValuesFrom saref:Measurement .
_:genid204 a owl:Restriction ;
owl:onProperty :spectrumMin ;
owl:allValuesFrom saref:Measurement .
_:genid205 a owl:Restriction ;
owl:onProperty :colorAppearance ;
owl:allValuesFrom xsd:string .
_:genid206 a owl:Restriction ;
owl:onProperty :colorRenderingIndex ;
owl:allValuesFrom xsd:integer .
_:genid207 a owl:Restriction ;
owl:onProperty :lampBallastType ;
owl:allValuesFrom xsd:string .
_:genid208 a owl:Restriction ;
owl:onProperty :lampCompensationType ;
owl:allValuesFrom xsd:string .
:Lamp rdfs:comment "A lamp is an artificial light source such as a light bulb or tube."@en ;
rdfs:label "Lamp"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcLamp" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifclamp.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_lamptypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#MedicalDevice
:MedicalDevice a owl:Class ;
rdfs:subClassOf :FlowTerminal ;
rdfs:comment "A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide."@en ;
rdfs:label "Medical device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcMedicalDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcmedicaldevice.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_medicaldevicetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Outlet
:Outlet a owl:Class ;
rdfs:subClassOf :FlowTerminal , _:genid209 .
_:genid209 a owl:Restriction ;
owl:onProperty :isPluggableOutlet ;
owl:allValuesFrom xsd:boolean .
_:genid210 a owl:Restriction ;
owl:onProperty :numberOsSockets ;
owl:allValuesFrom xsd:integer .
:Outlet rdfs:comment """An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications.
Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture."""@en ;
rdfs:label "Outlet"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcOutlet" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcoutlet.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_outlettypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#PhysicalObject
_:genid211 a owl:Restriction ;
owl:onProperty :contains ;
owl:allValuesFrom :PhysicalObject .
_:genid212 a owl:Restriction ;
owl:onProperty :isContainedIn ;
owl:allValuesFrom _:genid213 .
_:genid215 a rdf:List ;
rdf:first :BuildingSpace ;
rdf:rest _:genid214 .
_:genid214 a rdf:List ;
rdf:first :PhysicalObject ;
rdf:rest rdf:nil .
:PhysicalObject rdfs:comment "Any Object that has a proper space region. (Definition extracted from DUL ontology)"@en ;
rdfs:label "Physical object"@en .
#
# https://w3id.org/def/saref4bldg#ProtectiveDevice
:ProtectiveDevice a owl:Class ;
rdfs:subClassOf :FlowController ;
rdfs:comment """A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded.
A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection."""@en ;
rdfs:label "Protective device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcprotectivedevice.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_protectivedevicetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ProtectiveDeviceTrippingUnit
:ProtectiveDeviceTrippingUnit a owl:Class ;
rdfs:subClassOf :DistributionControlDevice , _:genid216 .
_:genid216 a owl:Restriction ;
owl:onProperty :limitingTerminalSize ;
owl:allValuesFrom saref:Measurement .
_:genid217 a owl:Restriction ;
owl:onProperty :standard ;
owl:allValuesFrom xsd:string .
:ProtectiveDeviceTrippingUnit rdfs:comment "A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded."@en ;
rdfs:label "Protective device tripping unit"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcProtectiveDeviceTrippingUnit" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcprotectivedevicetrippingunit.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_protectivedevicetrippingunittypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Pump
:Pump a owl:Class ;
rdfs:subClassOf :FlowMovingDevice , _:genid218 .
_:genid218 a owl:Restriction ;
owl:onProperty :connectionSize ;
owl:allValuesFrom saref:Measurement .
_:genid219 a owl:Restriction ;
owl:onProperty :flowResistanceMax ;
owl:allValuesFrom saref:Measurement .
_:genid220 a owl:Restriction ;
owl:onProperty :flowResistanceMin ;
owl:allValuesFrom saref:Measurement .
_:genid221 a owl:Restriction ;
owl:onProperty :netPositiveSuctionHead ;
owl:allValuesFrom saref:Measurement .
_:genid222 a owl:Restriction ;
owl:onProperty :nomminalRotationSpeed ;
owl:allValuesFrom saref:Measurement .
_:genid223 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid224 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid225 a owl:Restriction ;
owl:onProperty :pumpFlowRateMax ;
owl:allValuesFrom saref:Measurement .
_:genid226 a owl:Restriction ;
owl:onProperty :pumpFlowRateMin ;
owl:allValuesFrom saref:Measurement .
:Pump rdfs:comment "A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system."@en ;
rdfs:label "Pump"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcPump" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcpump.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_pumptypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#SanitaryTerminal
:SanitaryTerminal a owl:Class ;
rdfs:subClassOf :FlowTerminal ;
rdfs:comment "A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal."@en ;
rdfs:label "Sanitary terminal"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSanitaryTerminal" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/lexical/ifcsanitaryterminal.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcplumbingfireprotectiondomain/pset/pset_sanitaryterminaltypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Sensor
:Sensor a owl:Class ;
rdfs:subClassOf :DistributionControlDevice , saref:Sensor ;
rdfs:comment "A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument."@en ;
rdfs:label "Sensor"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSensor" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcsensor.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_sensortypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#ShadingDevice
:ShadingDevice a owl:Class ;
rdfs:subClassOf :BuildingDevice , _:genid227 .
_:genid227 a owl:Restriction ;
owl:onProperty :solarReflectance ;
owl:allValuesFrom saref:Measurement .
_:genid228 a owl:Restriction ;
owl:onProperty :solarTransmittance ;
owl:allValuesFrom saref:Measurement .
_:genid229 a owl:Restriction ;
owl:onProperty :thermalTransmittance ;
owl:allValuesFrom saref:Measurement .
_:genid230 a owl:Restriction ;
owl:onProperty :visibleLightReflectance ;
owl:allValuesFrom saref:Measurement .
_:genid231 a owl:Restriction ;
owl:onProperty :visibleLightTransmittance ;
owl:allValuesFrom saref:Measurement .
_:genid232 a owl:Restriction ;
owl:onProperty :isExternal ;
owl:allValuesFrom xsd:boolean .
_:genid233 a owl:Restriction ;
owl:onProperty :mechanicalOperated ;
owl:allValuesFrom xsd:boolean .
_:genid234 a owl:Restriction ;
owl:onProperty :roughness ;
owl:allValuesFrom xsd:string .
_:genid235 a owl:Restriction ;
owl:onProperty :shadingDeviceType ;
owl:allValuesFrom xsd:string .
:ShadingDevice rdfs:comment "Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable."@en ;
rdfs:label "Shading device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcShadingDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgelements/lexical/ifcshadingdevice.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgelements/pset/pset_shadingdevicecommon.htm> .
#
# https://w3id.org/def/saref4bldg#SolarDevice
:SolarDevice a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice ;
rdfs:comment "A solar device converts solar radiation into other energy such as electric current or thermal energy."@en ;
rdfs:label "Solar device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSolarDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcsolardevicetypeenum.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_solardevicetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#SpaceHeater
:SpaceHeater a owl:Class ;
rdfs:subClassOf :FlowTerminal , _:genid236 .
_:genid236 a owl:Restriction ;
owl:onProperty :bodyMass ;
owl:allValuesFrom saref:Measurement .
_:genid237 a owl:Restriction ;
owl:onProperty :outputCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid238 a owl:Restriction ;
owl:onProperty :thermalEfficiency ;
owl:allValuesFrom saref:Measurement .
_:genid239 a owl:Restriction ;
owl:onProperty :thermalMassHeatCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid240 a owl:Restriction ;
owl:onProperty :energySource ;
owl:allValuesFrom xsd:string .
_:genid241 a owl:Restriction ;
owl:onProperty :heatTransferDimension ;
owl:allValuesFrom xsd:string .
_:genid242 a owl:Restriction ;
owl:onProperty :heatTransferMedium ;
owl:allValuesFrom xsd:string .
_:genid243 a owl:Restriction ;
owl:onProperty :numberOfPanels ;
owl:allValuesFrom xsd:integer .
_:genid244 a owl:Restriction ;
owl:onProperty :numberOfSections ;
owl:allValuesFrom xsd:integer .
_:genid245 a owl:Restriction ;
owl:onProperty :placementType ;
owl:allValuesFrom xsd:string .
_:genid246 a owl:Restriction ;
owl:onProperty :temperatureClassification ;
owl:allValuesFrom xsd:string .
:SpaceHeater rdfs:comment """Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters.
UnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; Coil should be used for coil-based floor heating."""@en ;
rdfs:label "Space heater"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSpaceHeater" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcspaceheater.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_spaceheatertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#SwitchingDevice
:SwitchingDevice a owl:Class ;
rdfs:subClassOf :FlowController , _:genid247 .
_:genid247 a owl:Restriction ;
owl:onProperty :hasLock ;
owl:allValuesFrom xsd:boolean .
_:genid248 a owl:Restriction ;
owl:onProperty :isIlluminated ;
owl:allValuesFrom xsd:boolean .
_:genid249 a owl:Restriction ;
owl:onProperty :legend ;
owl:allValuesFrom xsd:string .
_:genid250 a owl:Restriction ;
owl:onProperty :numberOfGangs ;
owl:allValuesFrom xsd:integer .
_:genid251 a owl:Restriction ;
owl:onProperty :switchFunction ;
owl:allValuesFrom xsd:string .
:SwitchingDevice rdfs:comment """A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity.
Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports."""@en ;
rdfs:label "Switching device"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcSwitchingDevice" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcswitchingdevice.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_switchingdevicetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Tank
:Tank a owl:Class ;
rdfs:subClassOf :FlowStorageDevice , _:genid252 .
_:genid252 a owl:Restriction ;
owl:onProperty :effectiveCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid253 a owl:Restriction ;
owl:onProperty :firstCurvatureRadius ;
owl:allValuesFrom saref:Measurement .
_:genid254 a owl:Restriction ;
owl:onProperty :nominalDepth ;
owl:allValuesFrom saref:Measurement .
_:genid255 a owl:Restriction ;
owl:onProperty :nominalLengthOrDiameter ;
owl:allValuesFrom saref:Measurement .
_:genid256 a owl:Restriction ;
owl:onProperty :nominalVolumetricCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid257 a owl:Restriction ;
owl:onProperty :nominalWidthOrDiameter ;
owl:allValuesFrom saref:Measurement .
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
_:genid258 a owl:Restriction ;
owl:onProperty :operatingWight ;
owl:allValuesFrom saref:Measurement .
:Tank rdfs:subClassOf _:genid259 .
_:genid259 a owl:Restriction ;
owl:onProperty :secondCurvatureRadius ;
owl:allValuesFrom saref:Measurement .
:Tank rdfs:subClassOf _:genid260 .
_:genid260 a owl:Restriction ;
owl:onProperty :accessType ;
owl:allValuesFrom xsd:string .
:Tank rdfs:subClassOf _:genid261 .
_:genid261 a owl:Restriction ;
owl:onProperty :endShapeType ;
owl:allValuesFrom xsd:string .
:Tank rdfs:subClassOf _:genid262 .
_:genid262 a owl:Restriction ;
owl:onProperty :numberOfSections ;
owl:allValuesFrom xsd:integer .
:Tank rdfs:subClassOf _:genid263 .
_:genid263 a owl:Restriction ;
owl:onProperty :patternType ;
owl:allValuesFrom xsd:string .
:Tank rdfs:subClassOf _:genid264 .
_:genid264 a owl:Restriction ;
owl:onProperty :storageType ;
owl:allValuesFrom xsd:string .
:Tank rdfs:comment "A tank is a vessel or container in which a fluid or gas is stored for later use."@en ;
rdfs:label "Tank"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTank" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifctank.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_tanktypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Transformer
:Transformer a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid265 .
_:genid265 a owl:Restriction ;
owl:onProperty :apparentPowerMax ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid266 .
_:genid266 a owl:Restriction ;
owl:onProperty :imaginaryImpedanceRatio ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid267 .
_:genid267 a owl:Restriction ;
owl:onProperty :primaryApparentPower ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid268 .
_:genid268 a owl:Restriction ;
owl:onProperty :primaryCurrent ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid269 .
_:genid269 a owl:Restriction ;
owl:onProperty :primaryFrequency ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid270 .
_:genid270 a owl:Restriction ;
owl:onProperty :primaryVoltage ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid271 .
_:genid271 a owl:Restriction ;
owl:onProperty :realImpedanceRatio ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid272 .
_:genid272 a owl:Restriction ;
owl:onProperty :secondaryApparentPower ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid273 .
_:genid273 a owl:Restriction ;
owl:onProperty :secondaryCurrent ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid274 .
_:genid274 a owl:Restriction ;
owl:onProperty :secondaryFrequency ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid275 .
_:genid275 a owl:Restriction ;
owl:onProperty :secondaryVoltage ;
owl:allValuesFrom saref:Measurement .
:Transformer rdfs:subClassOf _:genid276 .
_:genid276 a owl:Restriction ;
owl:onProperty :isNeutralPrimaryTerminalAvailable ;
owl:allValuesFrom xsd:boolean .
:Transformer rdfs:subClassOf _:genid277 .
_:genid277 a owl:Restriction ;
owl:onProperty :isNeutralSecondaryTerminalAvailable ;
owl:allValuesFrom xsd:boolean .
:Transformer rdfs:subClassOf _:genid278 .
_:genid278 a owl:Restriction ;
owl:onProperty :secondaryCurrentType ;
owl:allValuesFrom xsd:string .
:Transformer rdfs:subClassOf _:genid279 .
_:genid279 a owl:Restriction ;
owl:onProperty :transformerVectorGroup ;
owl:allValuesFrom xsd:string .
:Transformer rdfs:comment """A transformer is an inductive stationary device that transfers electrical energy from one circuit to another.
Transformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: Controller converts arbitrary signals, AudioVisualAppliance converts signals for audio or video streams, and CommunicationsAppliance converts signals for data or other communications usage."""@en ;
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
rdfs:label "Transformer"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransformer" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifctransformer.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_transformertypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#TransportElement
:TransportElement a owl:Class ;
rdfs:subClassOf saref:Device , _:genid280 .
_:genid280 a owl:Restriction ;
owl:onProperty :capacityWeight ;
owl:allValuesFrom saref:Measurement .
:TransportElement rdfs:subClassOf _:genid281 .
_:genid281 a owl:Restriction ;
owl:onProperty :capacityPeople ;
owl:allValuesFrom xsd:positiveInteger .
:TransportElement rdfs:subClassOf _:genid282 .
_:genid282 a owl:Restriction ;
owl:onProperty :fireExit ;
owl:allValuesFrom xsd:boolean .
:TransportElement rdfs:comment "A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The TransportElement defines the occurrence of a transport element. "@en ;
rdfs:label "Transport element"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTransportElement" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifctransportelement.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/pset/pset_transportelementcommon.htm> .
#
# https://w3id.org/def/saref4bldg#TubeBundle
:TubeBundle a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid283 .
_:genid283 a owl:Restriction ;
owl:onProperty :foulingFactor ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid284 .
_:genid284 a owl:Restriction ;
owl:onProperty :horizontalSpacing ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid285 .
_:genid285 a owl:Restriction ;
owl:onProperty :inLineRowSpacing ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid286 .
_:genid286 a owl:Restriction ;
owl:onProperty :insideDiameter ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid287 .
_:genid287 a owl:Restriction ;
owl:onProperty :length ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid288 .
_:genid288 a owl:Restriction ;
owl:onProperty :nominalDiameter ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid289 .
_:genid289 a owl:Restriction ;
owl:onProperty :outsideDiameter ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid290 .
_:genid290 a owl:Restriction ;
owl:onProperty :staggeredRowSpacing ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid291 .
_:genid291 a owl:Restriction ;
owl:onProperty :thermalConductivity ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid292 .
_:genid292 a owl:Restriction ;
owl:onProperty :verticalSpacing ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid293 .
_:genid293 a owl:Restriction ;
owl:onProperty :volumen ;
owl:allValuesFrom saref:Measurement .
:TubeBundle rdfs:subClassOf _:genid294 .
_:genid294 a owl:Restriction ;
owl:onProperty :hasTurbulator ;
owl:allValuesFrom xsd:boolean .
:TubeBundle rdfs:subClassOf _:genid295 .
_:genid295 a owl:Restriction ;
owl:onProperty :numberOfCircuits ;
owl:allValuesFrom xsd:integer .
:TubeBundle rdfs:subClassOf _:genid296 .
_:genid296 a owl:Restriction ;
owl:onProperty :numberOfRows ;
owl:allValuesFrom xsd:integer .
:TubeBundle rdfs:comment "A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil."@en ;
rdfs:label "Tube bundle"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcTubeBundle" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifctubebundle.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_tubebundletypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#UnitaryControlElement
:UnitaryControlElement a owl:Class ;
rdfs:subClassOf :DistributionControlDevice ;
rdfs:comment """A unitary control element combines a number of control components into a single product, such as a thermostat or humidistat.
A unitary control element provides a housing for an aggregation of control or electrical distribution elements that, in combination, perform a singular (unitary) purpose. Each item in the aggregation may have its own geometric representation and location."""@en ;
rdfs:label "Unitary control element"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcUnitaryControlElement" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcunitarycontrolelement.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_unitarycontrolelementtypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#Valve
:Valve a owl:Class ;
rdfs:subClassOf :FlowController , _:genid297 .
_:genid297 a owl:Restriction ;
owl:onProperty :closeOffRating ;
owl:allValuesFrom saref:Measurement .
:Valve rdfs:subClassOf _:genid298 .
_:genid298 a owl:Restriction ;
owl:onProperty :flowCoefficient ;
owl:allValuesFrom saref:Measurement .
:Valve rdfs:subClassOf _:genid299 .
_:genid299 a owl:Restriction ;
owl:onProperty :size ;
owl:allValuesFrom saref:Measurement .
_:genid300 a owl:Restriction ;
owl:onProperty :testPressure ;
owl:allValuesFrom saref:Measurement .
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
:Valve rdfs:subClassOf _:genid301 .
_:genid301 a owl:Restriction ;
owl:onProperty :workingPressure ;
owl:allValuesFrom saref:Measurement .
:Valve rdfs:subClassOf _:genid302 .
_:genid302 a owl:Restriction ;
owl:onProperty :valveMechanism ;
owl:allValuesFrom xsd:string .
:Valve rdfs:subClassOf _:genid303 .
_:genid303 a owl:Restriction ;
owl:onProperty :valveOperation ;
owl:allValuesFrom xsd:string .
:Valve rdfs:subClassOf _:genid304 .
_:genid304 a owl:Restriction ;
owl:onProperty :valvePattern ;
owl:allValuesFrom xsd:string .
:Valve rdfs:comment "A valve is used in a building services piping distribution system to control or modulate the flow of the fluid."@en ;
rdfs:label "Valve"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcValve" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcvalve.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_valvetypecommon.htm> .
#
# https://w3id.org/def/saref4bldg#VibrationIsolator
:VibrationIsolator a owl:Class ;
rdfs:subClassOf saref:Device , _:genid305 .
_:genid305 a owl:Restriction ;
owl:onProperty :height ;
owl:allValuesFrom saref:Measurement .
:VibrationIsolator rdfs:subClassOf _:genid306 .
_:genid306 a owl:Restriction ;
owl:onProperty :isolatorCompressibility ;
owl:allValuesFrom saref:Measurement .
:VibrationIsolator rdfs:subClassOf _:genid307 .
_:genid307 a owl:Restriction ;
owl:onProperty :isolatorStaticDeflection ;
owl:allValuesFrom saref:Measurement .
:VibrationIsolator rdfs:subClassOf _:genid308 .
_:genid308 a owl:Restriction ;
owl:onProperty :supportedWeightMax ;
owl:allValuesFrom saref:Measurement .
:VibrationIsolator rdfs:subClassOf _:genid309 .
_:genid309 a owl:Restriction ;
owl:onProperty :vibrationTransmissibility ;
owl:allValuesFrom saref:Measurement .
:VibrationIsolator rdfs:comment "A vibration isolator is a device used to minimize the effects of vibration transmissibility in a building."@en ;
rdfs:label "Vibration isolator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcVibrationIsolator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcvibrationisolator.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_vibrationisolatortypecommon.htm> .
#
# https://w3id.org/saref#Actuator
saref:Actuator a owl:Class ;
rdfs:comment "A device responsible for moving or controlling a mechanism or system"@en ;
rdfs:isDefinedBy <https://w3id.org/saref#> ;
rdfs:label "Actuator"@en .
#
# https://w3id.org/saref#Device
saref:Device a owl:Class ;
rdfs:subClassOf :PhysicalObject ;
rdfs:comment "A tangible object designed to accomplish a particular task in households, common public buildings or offices. In order to accomplish this task, the device performs one or more functions. For example, a washing machine is designed to wash (task) and to accomplish this task it performs the start and stop function."@en ;
rdfs:isDefinedBy <https://w3id.org/saref#> ;
rdfs:label "Device"@en .
#
# https://w3id.org/saref#Measurement
saref:Measurement a owl:Class ;
rdfs:subClassOf _:genid310 .
_:genid310 a owl:Restriction ;
owl:onProperty saref:isMeasuredIn ;
owl:allValuesFrom saref:UnitOfMeasure .
saref:Measurement rdfs:subClassOf _:genid311 .
_:genid311 a owl:Restriction ;
owl:onProperty saref:relatesToProperty ;
owl:allValuesFrom saref:Property .
saref:Measurement rdfs:subClassOf _:genid312 .
_:genid312 a owl:Restriction ;
owl:onProperty saref:isMeasuredIn ;
owl:qualifiedCardinality "1"^^xsd:nonNegativeInteger ;
owl:onClass saref:UnitOfMeasure .
saref:Measurement rdfs:subClassOf _:genid313 .
_:genid313 a owl:Restriction ;
owl:onProperty saref:relatesToProperty ;
owl:qualifiedCardinality "1"^^xsd:nonNegativeInteger ;
owl:onClass saref:Property .
saref:Measurement rdfs:subClassOf _:genid314 .
_:genid314 a owl:Restriction ;
owl:onProperty saref:hasTimestamp ;
owl:allValuesFrom xsd:dateTime .
saref:Measurement rdfs:subClassOf _:genid315 .
_:genid315 a owl:Restriction ;
owl:onProperty saref:hasValue ;
owl:qualifiedCardinality "1"^^xsd:nonNegativeInteger ;
owl:onDataRange xsd:float .
saref:Measurement owl:disjointWith saref:Property , saref:UnitOfMeasure ;
rdfs:comment "Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement."@en ;
rdfs:isDefinedBy "https://w3id.org/saref#" ;
rdfs:label "Measurement"@en .
#
# https://w3id.org/saref#Property
saref:Property a owl:Class ;
owl:disjointWith saref:UnitOfMeasure ;
rdfs:comment "An aspect of an entity that can be observable by a sensor."@en ;
rdfs:isDefinedBy "https://w3id.org/saref#" ;
rdfs:label "Property"@en .
#
# https://w3id.org/saref#Sensor
saref:Sensor a owl:Class ;
rdfs:comment """A device that detects and responds to events or changes in the physical environment such as light, motion, or temperature changes.
A device that has category saref:Sensor and performs a saref:SensingFunction."""@en ;
rdfs:isDefinedBy <https://w3id.org/saref#> ;
rdfs:label "Sensor"@en .
#
# https://w3id.org/saref#UnitOfMeasure
saref:UnitOfMeasure a owl:Class ;
rdfs:comment "The unit of measure is a standard for measurement of a quantity, such as a Property. For example, Power is a property and Watt is a unit of power that represents a definite predetermined power: when we say 10 Watt, we actually mean 10 times the definite predetermined power called \"watt\". Our definition is based on the definition of unit of measure in the Ontology of units of Measure (OM). We propose here a list of some units of measure that are relevant for the purpose of the Smart Appliances ontology, but this list can be extended."@en ;
rdfs:isDefinedBy <https://w3id.org/saref#> ;
rdfs:label "Unit of measure"@en .
#
# Generated by the OWL API (version 4.2.6.20160910-2108) https://github.com/owlcs/owlapi