@@ -615,8 +615,16 @@ The CRA requires the manufacturer to keep all the documentation necessary to sho
The goal is that when the MSA does a “sweep” or otherwise decides to verify a product’s conformance with the CRA, it has enough information that it can do its own independent testing without unnecessary barriers that could be solved by vendor documentation (e.g., does not have to reverse-engineer how to attach a serial console and read logs). Note that it is easer for an MSA to evaluate conformance via transparency - reviewing the test output and documentation to evaluate whether a mitigation is implemented - over actually testing the product themselves.
A few assumptions that we are making:
* Manufacturers are already required to provide the ability to enable testing and collect output on the product as placed on the market, and will supply instructions for enabling and collecting test data.
* The MSA can and will request source code if desired.
Mitigations are how a technical requirement can be satisfied. Mitigations should be tailored to the use case and take into account the user’s sophistication and the operational environment.
Some risks may be transferred partially or fully to other components of the system or the user of the product. When that is the case, migitations that transfer the risk will be included as an option to fulfill a technical requirement, depending on the use case and risk factors.
Format:
### 5.2.X **TR-XXXX**:
@@ -651,15 +659,7 @@ _Description of mitigation implementing the requirement in "shall" format._
### 5.2.1 General
This section is a list of technical requirements necessary to satisfy the CRA essential requirements. Each technical requirement can be satisfied by one or more potential mitigations. Each mitigation may or may not be appropriate for an individual use case. The following section will define which mitigations will be required, depending on a risk factor, the overall risk tolerance, and/or a use case in the following section.
Some risks may be transferred partially or fully to other components of the system or the user of the product. When that is the case, migitations that transfer the risk will be included as an option to fulfill a technical requirement, depending on the use case and risk factors.
A few assumptions that we are making:
Manufacturers are already required to provide the ability to enable testing and collect output on the product as placed on the market, and will supply instructions for enabling and collecting test data.
The MSA can and will request source code if desired.
This section is a list of technical requirements necessary to satisfy the CRA essential requirements. Each technical requirement can be satisfied by one or more potential mitigations. Each mitigation may or may not be appropriate for an individual use case. The following section will define which mitigations will be required, depending on risk factors and/or a use case. See Annex C for more information.