@@ -1864,20 +1864,22 @@ For each cybersecurity requirements defined in clause 5, the following clauses s
#### 6.2.1.7 CYB_GENERAL-7
**Objective:** Where multiple monitoring sources all operate they shall have consistent system time where any drift or lack of synchronization shall be accurately documented and notification provided to administrator.
**Objective:** Where multiple monitoring targets are operating, all shall have consistent times. Any received alarm of a drift or asynchrony correction shall be accurately documented and notification provided to administrator.
**Preparation:**
1. Have the product initialised and available with the default configuration and required credentials.
1. Have the product initialised and available with the default configuration and required credentials;
2. Have a system node in operation;
3. Have a managed element in operation.
**Activities:**
1. Set a node or a system to a wrong time that is off by at least an hour;
2. Set a managed element or connected service to a wrong time that deviates from real time by at least one hour.
1. Set the node and the chosen managed element to a wrong time that is off by at least an hour;
2. Set connected system service to a wrong time that deviates from real time by at least one hour.
**Verdict:**
1. Pass, if system notices the drift,
1. Pass, if the product detects the drift correction