Newer
Older
# https://saref.etsi.org/saref4bldg/spectrumMin
:spectrumMin a owl:ObjectProperty ;
rdfs:comment "The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other."@en ;
rdfs:label "minimum spectrum"@en .
#
# https://saref.etsi.org/saref4bldg/staggeredRowSpacing
:staggeredRowSpacing a owl:ObjectProperty ;
rdfs:comment "Staggered tube row spacing. Usually measured in millimeters (mm)."@en ;
rdfs:label "staggered row spacing"@en .
#
# https://saref.etsi.org/saref4bldg/startCurrentFactor
:startCurrentFactor a owl:ObjectProperty ;
rdfs:comment "IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current."@en ;
rdfs:label "start current factor"@en .
#
# https://saref.etsi.org/saref4bldg/startingTime
:startingTime a owl:ObjectProperty ;
rdfs:comment "The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals."@en ;
rdfs:label "starting time"@en .
#
# https://saref.etsi.org/saref4bldg/supportedWeightMax
:supportedWeightMax a owl:ObjectProperty ;
rdfs:comment "The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "maximum supported weight"@en .
#
# https://saref.etsi.org/saref4bldg/teTime
:teTime a owl:ObjectProperty ;
rdfs:comment "The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device."@en ;
rdfs:label "te time"@en .
#
# https://saref.etsi.org/saref4bldg/temperatureRating
:temperatureRating a owl:ObjectProperty ;
rdfs:comment "Temperature rating. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "temperature rating"@en .
#
# https://saref.etsi.org/saref4bldg/testPressure
:testPressure a owl:ObjectProperty ;
rdfs:comment "The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "test pressure"@en .
#
# https://saref.etsi.org/saref4bldg/thermalConductivity
:thermalConductivity a owl:ObjectProperty ;
rdfs:comment "Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt."@en ;
rdfs:label "thermal conductivity"@en .
#
# https://saref.etsi.org/saref4bldg/thermalEfficiency
:thermalEfficiency a owl:ObjectProperty ;
rdfs:comment "Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input."@en ;
rdfs:label "thermal efficiency"@en .
#
# https://saref.etsi.org/saref4bldg/thermalMassHeatCapacity
:thermalMassHeatCapacity a owl:ObjectProperty ;
rdfs:comment "Product of component mass and specific heat."@en ;
rdfs:label "thermal mass heat capacity"@en .
#
# https://saref.etsi.org/saref4bldg/thermalTransmittance
:thermalTransmittance a owl:ObjectProperty ;
rdfs:comment "Rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin."@en ;
rdfs:label "thermal transmittance"@en .
#
# https://saref.etsi.org/saref4bldg/ventilatingPipeSize
:ventilatingPipeSize a owl:ObjectProperty ;
rdfs:comment "Size of the ventilating pipe(s). Usually measured in millimeters (mm)."@en ;
rdfs:label "ventilating pipe size"@en .
#
# https://saref.etsi.org/saref4bldg/verticalSpacing
:verticalSpacing a owl:ObjectProperty ;
rdfs:comment "Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm)."@en ;
rdfs:label "vertical spacing"@en .
#
# https://saref.etsi.org/saref4bldg/vibrationTransmissibility
:vibrationTransmissibility a owl:ObjectProperty ;
rdfs:comment "The vibration transmissibility percentage."@en ;
rdfs:label "vibration transmissibility"@en .
#
# https://saref.etsi.org/saref4bldg/visibleLightReflectance
:visibleLightReflectance a owl:ObjectProperty ;
rdfs:comment "Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit."@en ;
rdfs:label "visible light reflectance"@en .
#
# https://saref.etsi.org/saref4bldg/visibleLightTransmittance
:visibleLightTransmittance a owl:ObjectProperty ;
rdfs:comment "Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit."@en ;
rdfs:label "visible light transmittance"@en .
#
# https://saref.etsi.org/saref4bldg/volumen
:volumen a owl:ObjectProperty ;
rdfs:comment "Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3)."@en ;
rdfs:label "volumen"@en .
#
# https://saref.etsi.org/saref4bldg/waterInletTemperatureMax
:waterInletTemperatureMax a owl:ObjectProperty ;
rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "water inlet temperature range"@en .
#
# https://saref.etsi.org/saref4bldg/waterInletTemperatureMin
:waterInletTemperatureMin a owl:ObjectProperty ;
rdfs:comment "Allowable water inlet temperature range. Usually measured in degrees Kelvin (K)."@en ;
rdfs:label "water inlet temperature range"@en .
#
# https://saref.etsi.org/saref4bldg/waterPressureMax
:waterPressureMax a owl:ObjectProperty ;
rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "water pressure range"@en .
#
# https://saref.etsi.org/saref4bldg/waterPressureMin
:waterPressureMin a owl:ObjectProperty ;
rdfs:comment "Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "water pressure range"@en .
#
# https://saref.etsi.org/saref4bldg/waterRequirement
:waterRequirement a owl:ObjectProperty ;
rdfs:comment "Make-up water requirement. Usually measured in m3/s."@en ;
rdfs:label "water requirement"@en .
#
# https://saref.etsi.org/saref4bldg/waterStorageCapacity
:waterStorageCapacity a owl:ObjectProperty ;
rdfs:comment "Water storage capacity. Usually measured in cubic metre (m3)."@en ;
rdfs:label "water storage capacity"@en .
#
# https://saref.etsi.org/saref4bldg/weight
:weight a owl:ObjectProperty ;
rdfs:comment "The weight of the device. Usually measured in kilograms (kg) or grams (g)."@en ;
rdfs:label "weight"@en .
#
# https://saref.etsi.org/saref4bldg/workingPressure
:workingPressure a owl:ObjectProperty ;
rdfs:comment "The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "working pressure"@en .
#
# https://saref.etsi.org/saref4bldg/workingPressureMax
:workingPressureMax a owl:ObjectProperty ;
rdfs:comment "Maximum working pressure. Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "maximum working pressure"@en .
#
# https://saref.etsi.org/saref4bldg/workingPressureMin
:workingPressureMin a owl:ObjectProperty ;
rdfs:comment "Allowable minimum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2)."@en ;
rdfs:label "minimum working pressure"@en .
#
# https://saref.etsi.org/core/isMeasuredIn
saref:isMeasuredIn a owl:ObjectProperty ;
rdfs:comment "A relation between a measurement and the unit of measure in which the measurement value is expressed."@en ;
rdfs:isDefinedBy "https://saref.etsi.org/core/" ;
# https://saref.etsi.org/core/relatesToProperty
saref:relatesToProperty a owl:ObjectProperty ;
rdfs:comment "A relation between a measurement and the property such measurement is about."@en ;
rdfs:isDefinedBy "https://saref.etsi.org/core/" ;
rdfs:label "relates to property"@en .
#
#
#
# #################################################################
# #
# # Data properties
# #
# #################################################################
#
#
# https://saref.etsi.org/saref4bldg/accessType
:accessType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole."@en ;
rdfs:label "access type"@en .
#
# https://saref.etsi.org/saref4bldg/application
:application a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system."@en ;
rdfs:label "application"@en .
#
# https://saref.etsi.org/saref4bldg/arrangement
:arrangement a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above."@en ;
rdfs:label "arrangement"@en .
#
# https://saref.etsi.org/saref4bldg/bladeAction
:bladeAction a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Blade action."@en ;
rdfs:label "blade action"@en .
#
# https://saref.etsi.org/saref4bldg/bladeEdge
:bladeEdge a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Blade edge."@en ;
rdfs:label "blade edge"@en .
#
# https://saref.etsi.org/saref4bldg/bladeShape
:bladeShape a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Blade shape. Flat means triple V-groove."@en ;
rdfs:label "blade shape"@en .
#
# https://saref.etsi.org/saref4bldg/capacityControl
:capacityControl a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty."@en ;
rdfs:label "capacity control"@en .
#
# https://saref.etsi.org/saref4bldg/capacityControlType
:capacityControlType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper."@en ;
rdfs:label "capacity control type"@en .
#
# https://saref.etsi.org/saref4bldg/capacityPeople
:capacityPeople a owl:DatatypeProperty ;
rdfs:range xsd:nonNegativeInteger ;
rdfs:comment "Capacity of the transportation element measured in numbers of person."@en ;
rdfs:label "capacity people"@en .
#
# https://saref.etsi.org/saref4bldg/circuitType
:circuitType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "OpenCircuit: Exposes water directly to the cooling atmosphere. CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger. Wet: The air stream or the heat exchange surface is evaporatively cooled. Dry: No evaporation into the air stream. DryWet: A combination of a dry tower and a wet tower."@en ;
rdfs:label "circuit type"@en .
#
# https://saref.etsi.org/saref4bldg/colorAppearance
:colorAppearance a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance."@en ;
rdfs:label "color appearance"@en .
#
# https://saref.etsi.org/saref4bldg/colorRenderingIndex
:colorRenderingIndex a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties."@en ;
rdfs:label "color rendering index"@en .
#
# https://saref.etsi.org/saref4bldg/controlStrategy
:controlStrategy a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature. WetBulbTempReset: The set-point is reset based on the wet-bulb temperature."@en ;
rdfs:label "control strategy"@en .
#
# https://saref.etsi.org/saref4bldg/endShapeType
:endShapeType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5"@en ;
rdfs:label "end shape type"@en .
#
# https://saref.etsi.org/saref4bldg/energySource
:energySource a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the energy source or fuel cumbusted to generate heat."@en , "The source of energy."@en ;
rdfs:label "energy source"@en .
#
# https://saref.etsi.org/saref4bldg/evaporationCoolant
:evaporationCoolant a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The fluid used for the coolant in the evaporator."@en ;
rdfs:label "evaporation coolant"@en .
#
# https://saref.etsi.org/saref4bldg/evaporationMediumType
:evaporationMediumType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant."@en ;
rdfs:label "evaporation medium type"@en .
#
# https://saref.etsi.org/saref4bldg/failPosition
:failPosition a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Specifies the required fail-safe position of the actuator."@en ;
rdfs:label "fail position"@en .
#
# https://saref.etsi.org/saref4bldg/finishColor
:finishColor a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Finish color for cooled beam."@en ;
rdfs:label "finish color"@en .
#
# https://saref.etsi.org/saref4bldg/fireExit
:fireExit a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes."@en ;
rdfs:label "fire exit"@en .
#
# https://saref.etsi.org/saref4bldg/flowArrangement
:flowArrangement a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: air and water flow enter in same directions."@en ;
rdfs:label "flow arrangement"@en .
#
# https://saref.etsi.org/saref4bldg/frameSize
:frameSize a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard."@en ;
rdfs:label "frame size"@en .
#
# https://saref.etsi.org/saref4bldg/frameType
:frameType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.)."@en ;
rdfs:label "frame type"@en .
#
# https://saref.etsi.org/saref4bldg/hasDefrost
:hasDefrost a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Whether the heat exchanger has defrost function or not."@en ;
rdfs:label "has defrost"@en .
#
# https://saref.etsi.org/saref4bldg/hasExteriorInsulation
:hasExteriorInsulation a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "TRUE if the silencer has exterior insulation. FALSE if it does not."@en ;
rdfs:label "has exterior insulation"@en .
#
# https://saref.etsi.org/saref4bldg/hasHotGasBypass
:hasHotGasBypass a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No."@en ;
rdfs:label "has hot gas bypass"@en .
#
# https://saref.etsi.org/saref4bldg/hasLock
:hasLock a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE)."@en ;
rdfs:label "has lock"@en .
#
# https://saref.etsi.org/saref4bldg/hasPartWinding
:hasPartWinding a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) ."@en ;
rdfs:label "has part winding"@en .
#
# https://saref.etsi.org/saref4bldg/hasTurbulator
:hasTurbulator a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "TRUE if the tube has a turbulator, FALSE if it does not."@en ;
rdfs:label "has turbulator"@en .
#
# https://saref.etsi.org/saref4bldg/heatTransferDimension
:heatTransferDimension a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates how heat is transmitted according to the shape of the space heater."@en ;
rdfs:label "heat transfer dimension"@en .
#
# https://saref.etsi.org/saref4bldg/heatTransferMedium
:heatTransferMedium a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the heat transfer medium if applicable."@en ;
rdfs:label "heat transfer medium"@en .
#
# https://saref.etsi.org/saref4bldg/heatTransferTypeEnum
:heatTransferTypeEnum a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Type of heat transfer between the two air streams."@en ;
rdfs:label "heat transfer type enum"@en .
#
# https://saref.etsi.org/saref4bldg/integratedLightingType
:integratedLightingType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Integrated lighting in cooled beam."@en ;
rdfs:label "integrated lighting type"@en .
#
# https://saref.etsi.org/saref4bldg/internalControl
:internalControl a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Internal modulation control."@en ;
rdfs:label "internal control"@en .
#
# https://saref.etsi.org/saref4bldg/isExternal
:isExternal a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building."@en ;
rdfs:label "is external"@en .
#
# https://saref.etsi.org/saref4bldg/isFreeHanging
:isFreeHanging a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Is it free hanging type (not mounted in a false ceiling)?"@en ;
rdfs:label "is free hanging"@en .
#
# https://saref.etsi.org/saref4bldg/isGuarded
:isGuarded a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE)."@en ;
rdfs:label "is guarded"@en .
#
# https://saref.etsi.org/saref4bldg/isIlluminated
:isIlluminated a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is illuminated"@en .
#
# https://saref.etsi.org/saref4bldg/isNeutralPrimaryTerminalAvailable
:isNeutralPrimaryTerminalAvailable a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is neutral primary terminal available"@en .
#
# https://saref.etsi.org/saref4bldg/isNeutralSecondaryTerminalAvailable
:isNeutralSecondaryTerminalAvailable a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE)."@en ;
rdfs:label "is neutral secondary terminal available"@en .
#
# https://saref.etsi.org/saref4bldg/isPluggableOutlet
:isPluggableOutlet a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN)."@en ;
rdfs:label "is pluggable outlet"@en .
#
# https://saref.etsi.org/saref4bldg/isWaterStorageHeater
:isWaterStorageHeater a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater."@en ;
rdfs:label "is water storage heater"@en .
#
# https://saref.etsi.org/saref4bldg/lampBallastType
:lampBallastType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz)."@en ;
rdfs:label "lamp ballast type"@en .
#
# https://saref.etsi.org/saref4bldg/lampCompensationType
:lampCompensationType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Identifies the form of compensation used for power factor correction and radio suppression."@en ;
rdfs:label "lamp compensation type"@en .
#
# https://saref.etsi.org/saref4bldg/legend
:legend a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A text inscribed or applied to the switch as a legend to indicate purpose or function."@en ;
rdfs:label "legend"@en .
#
# https://saref.etsi.org/saref4bldg/manualOverride
:manualOverride a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator."@en ;
rdfs:label "manual override"@en .
#
# https://saref.etsi.org/saref4bldg/mechanicalOperated
:mechanicalOperated a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE)."@en ;
rdfs:label "mechanical operated"@en .
#
# https://saref.etsi.org/saref4bldg/mediaSource
:mediaSource a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates media sources and corresponding names of ports (DistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (AudioVisualAppliance)."@en ;
rdfs:label "media source"@en .
#
# https://saref.etsi.org/saref4bldg/motorDriveType
:motorDriveType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type. "@en ;
rdfs:label "motor drive type"@en .
#
# https://saref.etsi.org/saref4bldg/motorEnclosureType
:motorEnclosureType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A list of the available types of motor enclosure from which that required may be selected."@en ;
rdfs:label "motor enclosure type"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfBlades
:numberOfBlades a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of blades."@en ;
rdfs:label "number of blades"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfCells
:numberOfCells a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of cells in one cooling tower unit."@en ;
rdfs:label "number of cells"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfCircuits
:numberOfCircuits a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of parallel fluid tube circuits."@en ;
rdfs:label "number of circuits"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfGangs
:numberOfGangs a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of gangs/buttons on this switch."@en ;
rdfs:label "number of gangs"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfPanels
:numberOfPanels a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of panels."@en ;
rdfs:label "number of panels"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfRows
:numberOfRows a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of tube rows in the tube bundle assembly."@en ;
rdfs:label "number of rows"@en .
#
# https://saref.etsi.org/saref4bldg/numberOfSections
:numberOfSections a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "Number of sections used."@en ;
rdfs:label "number of sections"@en .
#
# https://saref.etsi.org/saref4bldg/numberOsSockets
:numberOsSockets a owl:DatatypeProperty ;
rdfs:range xsd:integer ;
rdfs:comment "The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence."@en ;
rdfs:label "number os sockets"@en .
#
# https://saref.etsi.org/saref4bldg/operatingMode
:operatingMode a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Identifies the operating mode of the boiler."@en ;
rdfs:label "operating mode"@en .
#
# https://saref.etsi.org/saref4bldg/operation
:operation a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The operational mechanism for the damper operation."@en ;
rdfs:label "operation"@en .
#
# https://saref.etsi.org/saref4bldg/orientation
:orientation a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The intended orientation for the damper as specified by the manufacturer."@en ;
rdfs:label "orientation"@en .
#
# https://saref.etsi.org/saref4bldg/patternType
:patternType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the types of pattern (or shape of a tank that may be specified."@en ;
rdfs:label "pattern type"@en .
#
# https://saref.etsi.org/saref4bldg/pipeConnectionEnum
:pipeConnectionEnum a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The manner in which the pipe connection is made to the cooled beam."@en ;
rdfs:label "pipe connection enum"@en .
#
# https://saref.etsi.org/saref4bldg/placementType
:placementType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates how the device is designed to be placed."@en ;
rdfs:label "placement type"@en .
#
# https://saref.etsi.org/saref4bldg/powerSource
:powerSource a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Type of power driving the compressor."@en ;
rdfs:label "power source"@en .
#
# https://saref.etsi.org/saref4bldg/readOutType
:readOutType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer."@en ;
rdfs:label "read out type"@en .
#
# https://saref.etsi.org/saref4bldg/refrigerantClass
:refrigerantClass a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons."@en ;
rdfs:label "refrigerant class"@en .
#
# https://saref.etsi.org/saref4bldg/remoteReading
:remoteReading a owl:DatatypeProperty ;
rdfs:range xsd:boolean ;
rdfs:comment "Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE)."@en ;
rdfs:label "remote reading"@en .
#
# https://saref.etsi.org/saref4bldg/roughness
:roughness a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A measure of the vertical deviations of the surface."@en ;
rdfs:label "roughness"@en .
#
# https://saref.etsi.org/saref4bldg/secondaryCurrentType
:secondaryCurrentType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "A list of the secondary current types that can result from transformer output."@en ;
rdfs:label "secondary current type"@en .
#
# https://saref.etsi.org/saref4bldg/shadingDeviceType
:shadingDeviceType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Specifies the type of shading device."@en ;
rdfs:label "shading device type"@en .
#
# https://saref.etsi.org/saref4bldg/sprayType
:sprayType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "SprayFilled: Water is sprayed into airflow. SplashTypeFill: water cascades over successive rows of splash bars. FilmTypeFill: water flows in a thin layer over closely spaced sheets."@en ;
rdfs:label "spray type"@en .
#
# https://saref.etsi.org/saref4bldg/standard
:standard a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The designation of the standard applicable for the definition of the characteristics of the unit."@en ;
rdfs:label "standard"@en .
#
# https://saref.etsi.org/saref4bldg/storageType
:storageType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Defines the general material category intended to be stored."@en ;
rdfs:label "storage type"@en .
#
# https://saref.etsi.org/saref4bldg/switchFunction
:switchFunction a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Indicates types of switches which differs in functionality."@en ;
rdfs:label "switch function"@en .
#
# https://saref.etsi.org/saref4bldg/temperatureClassification
:temperatureClassification a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam."@en ;
rdfs:label "temperature classification"@en .
#
# https://saref.etsi.org/saref4bldg/transformerVectorGroup
:transformerVectorGroup a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers."@en ;
rdfs:label "transformer vector group"@en .
#
# https://saref.etsi.org/saref4bldg/valveMechanism
:valveMechanism a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal."@en ;
rdfs:label "valve mechanism"@en .
#
# https://saref.etsi.org/saref4bldg/valveOperation
:valveOperation a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve."@en ;
rdfs:label "valve operation"@en .
#
# https://saref.etsi.org/saref4bldg/valvePattern
:valvePattern a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports."@en ;
rdfs:label "valve pattern"@en .
#
# https://saref.etsi.org/saref4bldg/waterFlowControlSystemType
:waterFlowControlSystemType a owl:DatatypeProperty ;
rdfs:range xsd:string ;
rdfs:comment "Factory fitted waterflow control system."@en ;
rdfs:label "water flow control system type"@en .
#
# https://saref.etsi.org/core/hasTimestamp
saref:hasTimestamp a owl:DatatypeProperty , owl:FunctionalProperty ;
rdfs:range xsd:dateTime ;
rdfs:comment "A relationship stating the timestamp of an entity (e.g. a measurement)."@en ;
rdfs:isDefinedBy "https://saref.etsi.org/core/" ;
# https://saref.etsi.org/core/hasValue
saref:hasValue a owl:DatatypeProperty ;
rdfs:comment "A relationship defining the value of a certain property, e.g., energy or power"@en ;
rdfs:isDefinedBy <https://saref.etsi.org/core/> ;
rdfs:label "has value"@en .
#
#
#
# #################################################################
# #
# # Classes
# #
# #################################################################
#
#
# https://saref.etsi.org/saref4bldg/Actuator
:Actuator a owl:Class ;
rdfs:subClassOf :DistributionControlDevice , saref:Actuator , _:genid1 .
_:genid1 a owl:Restriction ;
owl:onProperty :failPosition ;
owl:allValuesFrom xsd:string .
:Actuator rdfs:subClassOf _:genid2 .
_:genid2 a owl:Restriction ;
owl:onProperty :manualOverride ;
owl:allValuesFrom xsd:boolean .
:Actuator rdfs:comment "An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion."@en ;
rdfs:label "Actuator"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcActuator" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcactuator.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_actuatortypecommon.htm> .
#
# https://saref.etsi.org/saref4bldg/AirToAirHeatRecovery
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
:AirToAirHeatRecovery a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid3 .
_:genid3 a owl:Restriction ;
owl:onProperty :operationTemperatureMax ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid4 .
_:genid4 a owl:Restriction ;
owl:onProperty :operationTemperatureMin ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid5 .
_:genid5 a owl:Restriction ;
owl:onProperty :primaryAirFlowRateMax ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid6 .
_:genid6 a owl:Restriction ;
owl:onProperty :primaryAirFlowRateMin ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid7 .
_:genid7 a owl:Restriction ;
owl:onProperty :secondaryAirFlowRateMax ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid8 .
_:genid8 a owl:Restriction ;
owl:onProperty :secondaryAirFlowRateMin ;
owl:allValuesFrom saref:Measurement .
:AirToAirHeatRecovery rdfs:subClassOf _:genid9 .
_:genid9 a owl:Restriction ;
owl:onProperty :hasDefrost ;
owl:allValuesFrom xsd:boolean .
:AirToAirHeatRecovery rdfs:subClassOf _:genid10 .
_:genid10 a owl:Restriction ;
owl:onProperty :heatTransferTypeEnum ;
owl:allValuesFrom xsd:string .
:AirToAirHeatRecovery rdfs:comment "An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements."@en ;
rdfs:label "Air to air heat recovery"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAirToAirHeatRecovery" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcairtoairheatrecovery.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_airtoairheatrecoverytypecommon.htm> .
#
# https://saref.etsi.org/saref4bldg/Alarm
:Alarm a owl:Class ;
rdfs:subClassOf :DistributionControlDevice ;
rdfs:comment """An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device.
Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms."""@en ;
rdfs:label "Alarm"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAlarm" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/lexical/ifcalarm.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcbuildingcontrolsdomain/pset/pset_alarmtypecommon.htm> .
#
# https://saref.etsi.org/saref4bldg/AudioVisualAppliance
:AudioVisualAppliance a owl:Class ;
rdfs:subClassOf :FlowTerminal , _:genid11 .
_:genid11 a owl:Restriction ;
owl:onProperty :audioVolume ;
owl:allValuesFrom saref:Measurement .
_:genid12 a owl:Restriction ;
owl:onProperty :mediaSource ;
owl:allValuesFrom xsd:string .
:AudioVisualAppliance rdfs:comment """An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video.
Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only."""@en ;
rdfs:label "Audio visual appliance"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcAudioVisualApplicance" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/lexical/ifcaudiovisualappliance.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcelectricaldomain/pset/pset_audiovisualappliancetypecommon.htm> .
#
# https://saref.etsi.org/saref4bldg/Boiler
:Boiler a owl:Class ;
rdfs:subClassOf :EnergyConversionDevice , _:genid13 .
_:genid13 a owl:Restriction ;
owl:onProperty :heatTransferSurfaceArea ;
owl:allValuesFrom saref:Measurement .
_:genid14 a owl:Restriction ;
owl:onProperty :nominalEnergyConsumption ;
owl:allValuesFrom saref:Measurement .
_:genid15 a owl:Restriction ;
owl:onProperty :nominalPartLoadRatio ;
owl:allValuesFrom saref:Measurement .
_:genid16 a owl:Restriction ;
owl:onProperty :outletTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid17 a owl:Restriction ;
owl:onProperty :outletTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid18 a owl:Restriction ;
owl:onProperty :pressureRating ;
owl:allValuesFrom saref:Measurement .
_:genid19 a owl:Restriction ;
owl:onProperty :waterInletTemperatureMax ;
owl:allValuesFrom saref:Measurement .
_:genid20 a owl:Restriction ;
owl:onProperty :waterInletTemperatureMin ;
owl:allValuesFrom saref:Measurement .
_:genid21 a owl:Restriction ;
owl:onProperty :waterStorageCapacity ;
owl:allValuesFrom saref:Measurement .
_:genid22 a owl:Restriction ;
owl:onProperty :energySource ;
owl:allValuesFrom xsd:string .
_:genid23 a owl:Restriction ;
owl:onProperty :isWaterStorageHeater ;
owl:allValuesFrom xsd:boolean .
_:genid24 a owl:Restriction ;
owl:onProperty :operatingMode ;
owl:allValuesFrom xsd:string .
:Boiler rdfs:comment "A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications."@en ;
rdfs:label "Boiler"@en ;
rdfs:seeAlso "https://w3id.org/ifc/IFC4_ADD1#IfcBoiler" ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/lexical/ifcboiler.htm> , <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifchvacdomain/pset/pset_boilertypecommon.htm> .
#
# https://saref.etsi.org/saref4bldg/Building
_:genid25 a owl:Restriction ;
owl:onProperty :hasSpace ;
owl:allValuesFrom :BuildingSpace .
:Building rdfs:comment "A building represents a structure that provides shelter for its occupants or contents and stands in one place. The building is also used to provide a basic element within the spatial structure hierarchy for the components of a building project (together with site, storey, and space)."@en ;
rdfs:label "Building"@en ;
rdfs:seeAlso <https://w3id.org/ifc/IFC4_ADD1#IfcBuilding> ;
prov:hadPrimarySource <http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifcbuilding.htm> .
#
# https://saref.etsi.org/saref4bldg/BuildingDevice
:BuildingDevice a owl:Class ;
rdfs:subClassOf :BuildingObject , saref:Device ;
rdfs:comment "A tangible object designed to accomplish a particular task in a building."@en ;
rdfs:label "Building device"@en .
#
# https://saref.etsi.org/saref4bldg/BuildingObject
:BuildingObject a owl:Class ;
rdfs:subClassOf :PhysicalObject ;
rdfs:comment "An object in the building that can be controlled by devices, such as a door or a window that can be automatically opened or closed by an actuator. (Definition taken from SAREF 1.0)"@en ;
rdfs:label "Building object"@en .